background image

20 

 

 

Updating DN-60 Firmware 

 
From time to time Datavideo may release new firmware to either add new features or to fix reported 
bugs in the current DN-60 firmware. Customers can update the DN-60 firmware themselves if they 
wish or they can contact their local dealer or reseller for assistance should they prefer this method.  
 
This page describes the firmware update process, it should take 

approximately  15  minutes total 

time to complete

.  

 
Once started 

the update process should not be interrupted in any way

  as this could result in a 

non-responsive unit.  
 

As well as a working DN-60 you will need: 
 

  The latest Firmware update for the DN-60.  

This can be obtained from your local Datavideo office or dealer. 

  The DN-60 power supply. 

  A blank qualified* CF card with capacity up to 32GB 

  A CF card reader if your computer does not already have CF card slot fitted.  

  A PC or Mac computer. 

 

*See page 17 also 

 
The DN-60 formatted CF card appears to the computer as a disk volume and not as a video device. 
The connection to the computer is done via the CF card slot in the computer or an attached CF card 
reader. The DN-60 CF card volume name is shown as 

Datavideoxx (xx

 is a value between 0 and 99). 

 

To update the DN-60’s firmware:  

 

1.  Use a CF card that is smaller than 64GB to update the DN-60. 
2.  Disconnect any IEEE-1394/DV/HDV cable from the DN-60. 
3.  Ensure the DN-60 power adaptor is supplying power to the DN-60 during the upgrade 

process. 

4.  Unzip the DN-60 2010.XX.XX.zip folder and copy the file flash to your computer desktop so it 

is easy to locate. 

5.  Use the DN-60 to format the CF card to FAT32, once formatted switch off the DN-60. 
6.  Eject the CF card from the DN-60 using the button next to it and attach it to the computer 

using a CF card reader or slot 

7.  Copy the file now called flash from your computer desktop to the DN-60 formatted CF card. 
8.  Insert the CF card back into the DN-60 and then turn the unit on. 
9.  At the DN-60 menu enter the Tools menu and choose the Upgrade Firmware option. 
10.  Confirm yes at the question are you sure? 
11.  The unit should now update itself. Please wait until the process ends and the units display 

has returned to the Home Screen showing the Record Mode option. 

12.  Now look at the Firmware Revision option under the DN-60 Tools menu to confirm the new 

firmware number is now shown. 

 
*WARNING:
 Once the option has been selected, DO NOT turn power off until the firmware has been 
updated. If the update is prematurely ended the recorder will be made inoperable. 

Summary of Contents for DN-60

Page 1: ...1 HDV SD CF CARD VIDEO RECORDER DN 60 Instruction Manual www datavideo tek com...

Page 2: ...etup Options 13 System Set Up 14 Save Set Up 14 Recall Set Up 14 DN 60 General Setup Notes 15 Choose a file operating system FAT32 or NTFS 15 Set the CF card volume ID 15 Set the Signal Type 15 Set Fi...

Page 3: ...Specifications 27 Service and Support 28 Disclaimer of Product and Services The information offered in this instruction manual is intended as a guide only At all times Datavideo Technologies will try...

Page 4: ...4 dealer...

Page 5: ...at could result in risk of fire or electric shock Never spill liquid of any kind onto or into this unit 12 Except as specifically explained elsewhere in this manual do not attempt to service this prod...

Page 6: ...ree one year extension to the standard Warranty providing the product is registered with Datavideo within 30 days of purchase For information on how to register please visit www datavideo tek com or c...

Page 7: ...s M2T in HDV mode With this many useful features the DN 60 is ideal for a variety applications within broadcast education animation science medical construction and security See page 17 Features Small...

Page 8: ...8...

Page 9: ...ower adaptor here 4 Status LED 5 Power On Auto Off switch 6 CF Card Protection Cover Slide down then lift up carefully to gain access Rear Panel 1 Battery Compartment Cover Press in gently and slide u...

Page 10: ...fitted CF card When the slot is empty no CF card inserted this button is normally in the depressed position Upon inserting a CF card the button moves out again NOTE CF cards need to be inserted the co...

Page 11: ...DC input socket Note Not all AA labelled batteries are manufactured to the same dimensions so care must be taken when selecting batteries for use with the DN 60 Some batteries because of their non sta...

Page 12: ...DN 60 into record mode when the menu navigation button is pressed in At this point the DN 60 checks for the chosen input signal DV DVC Pro or HDV at the IEEE 1394 connector Use Status mode to check t...

Page 13: ...parameters and modes to be setup Menu Option Action taken Exit Will return you to the SET UP menu SET FILE TYPE The file options change depending on the Signal Type chosen in System Set Up DV and DVC...

Page 14: ...be marked with an asterisk SET BATTERY TYPE This option allows the proper display of remaining power from Alkaline NiMH 1 NiMH 2 or Lithium type battery cells SET DV HIDDEN MODE Allows user to enable...

Page 15: ...the standard chosen is DV DVC 60Hz then the NTSC IRE LEVEL is dictated by the source equipment or camera Set File Type The choices for file types are dependent on the Signal Type chosen Types availabl...

Page 16: ...es 3 4 5 on pages 11 and 12 Starting the Record Process Common ways of starting to record with the DN 60 are 1 Manually by switching the units Sync to Tape feature off and selecting Record mode whilst...

Page 17: ...the Interval minutes value between 0 and 59 minutes Set the Interval seconds value between 0 and 59 seconds Set the Frames to record value between 0 and 15 Frames Once set select TIMELAPSE ON and pres...

Page 18: ...process under TOOLS mode must be undertaken otherwise the computer may see a blank card This menu operation prepares the recorded video content on the CF card to be seen by a computer by building pre...

Page 19: ...ty pdf Below for convenience is an initial list of CF media that you may wish to consider Brand CF Card Name Data Rate Size Max Record Time Approx DV25 HDV DVC Pro 25 DVC Pro 50 SanDisk Extreme III 30...

Page 20: ...videoxx xx is a value between 0 and 99 To update the DN 60 s firmware 1 Use a CF card that is smaller than 64GB to update the DN 60 2 Disconnect any IEEE 1394 DV HDV cable from the DN 60 3 Ensure the...

Page 21: ...lay of up to 700 msec During this busy time all commands will be ignored Summary List of Commands Command Name Response Name System Control 00h 11h 11h Device Type Request 12h 11h 00h 00h 23h Device T...

Page 22: ...bin is 1 then the next bin is 99 02h F5h 08h 00h FFh Disable Loop Play When this command is issued from the Idle state the Loop Play feature is disabled Loop Play is where the the last play command i...

Page 23: ...nn Content of the present bin is played at 1x speed starting at Frame Offset nn This command may be issued from the Idle state or any other Play state 24h F3h bb nn Select Bin and Play Offset Bin num...

Page 24: ...ds JOG VARIABLE or SHUTTLE the unit will play forward or backward according to the speed data The first data byte may only be a maximum of 80 Play Speed 10 nn 32 2 Note that setting nn to 0 will resul...

Page 25: ...25...

Page 26: ...is allows the user trial access to the software for evaluation and any video files converted will show watermark text in the video playback An activation code allows the software to produce files with...

Page 27: ...opus mov mxf OP1A HDV m2t Operating File System Compatibility FAT32 NTFS Input Voltage Requirement 12V typical 8V min 24V max Power Consumption 12V Idle 4 3W Play Record 6W HDD mode 5 3W Size H x W x...

Page 28: ...pe BV Tel 31 30 261 96 56 Fax 31 30 261 96 57 E Mail service datavideo nl Datavideo UK Limited Tel 44 1457 851 000 Fax 44 1457 850 964 E Mail sales datavideo co uk Datavideo Technologies Co Ltd Tel 88...

Page 29: ...29...

Reviews: