background image

7

 

 

Introduction 

Thank  you  for  purchasing  the  Datavideo  TC-200,  Title  Creator,  overlay  box. 
The  TC-200  can  be  used  with  Datavideo’s  Windows  based  Character 
Generator  software  such  as  CG-200,  CG-250,  CG-350  and  CG-500.  The  CG 
Software Series and the TC-200 Title Creator form a DSK subtitle system that 
allows you  to create  professional  and eye-catching  DSK  subtitles  using  your 
laptop,  thereby  simplifying  and  facilitating  your  video  production  using 
mobile switchers. 

The TC-200 is designed to be portable and rugged as well as quick and easy 
to set up in the field. It allows producers to create professional CG overlays 
with  a  Windows  laptop  instead  of  transporting  a  high  end desktop  PC with 
PCIe cards fitted. 

The TC-200 Title Creator allows you to create subtitles with your switcher in 
two different ways.   

1. Downstream Key 
You  may  assign  alpha  signal  (key  source)  and  T-signal  (fill  source)  to 
respective  outputs  of  the  TC-200  and  then  connect  them  to  any  switchers 
equipped  with  the  DSK  function  such  as  Datavideo’s  HS-2800  or  HS-1200 
switcher. 

2. CG Overlay 
TC-200  may  be configured  as  a  CG  overlay  device  that  accepts  external  SDI 
video  which is  then combined  internally  with  the  subtitles and  delivered  to 
the device output. CG overlay is generally used for switchers without the DSK 
capability or videos created without subtitles. 

This  manual  covers  the  TC-200  overlay  box  only,  a  separate  manual  is 
provided with the supplied Character Generator software. 

Features 

 

HDMI input for laptop CG overlay input*.   

 

HD/SD-SDI video input for overlay or optional genlock 

 

Two HD/SD-SDI outputs can be configured as separate Key & Fill outputs 
or as CG overlay with video 

Summary of Contents for CG-350TC Kit

Page 1: ...TC 200 w w w d a t a v i d e o c o m Instruction manual TITLE CREATOR...

Page 2: ...mes Datavideo Technologies will try to give correct complete and suitable information However Datavideo Technologies cannot exclude that some information in this manual from time to time may not be co...

Page 3: ...ot place this unit on a bed sofa rug or similar surface as the ventilation openings on the bottom of the cabinet will be blocked This unit should never be placed near or over a heat register or radiat...

Page 4: ...ied service personnel under the following conditions a When the power cord is damaged or frayed b When liquid has spilled into the unit c When the product has been exposed to rain or water d When the...

Page 5: ...ter systems are not covered under warranty Any errors that are caused by unauthorized third party software installations which are not required by our computer systems are not covered under warranty A...

Page 6: ...collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environme...

Page 7: ...eator allows you to create subtitles with your switcher in two different ways 1 Downstream Key You may assign alpha signal key source and T signal fill source to respective outputs of the TC 200 and t...

Page 8: ...sitioned on either side of the screen top bottom left and right Unit can be powered from Battery DC voltage when using an accessory battery mounting plate 7 to 15 V DC Input Easy to follow DIP switch...

Page 9: ...9 Example Set Up with TC 200...

Page 10: ...10 Connections Controls Front Panel Mode Select The DIP switch allows the user to configure the following TC 200 settings SDI Output Fill Key channel outputs...

Page 11: ...Input The SDI IN connects an SDI video source via an SDI cable Note The TC 200 does not support external tri level sync and black burst genlock signals It however uses the sync of the SDI input sourc...

Page 12: ...hernet Network Interface for FW upgrade see Firmware Update for more details DC In Socket Connect the supplied 12V PSU to this socket The connection can be secured by screwing the outer fastening ring...

Page 13: ...0 0 1080i50Hz 0 0 1 1080i60Hz 0 1 0 1080i59 94Hz 0 1 1 720p50Hz 1 0 0 720p60Hz 1 0 1 720p59 94Hz 1 1 0 576i50Hz 1 1 1 480i59 94Hz DIP Switch 4 5 Conversion Modes 0 0 Split HDMI signal into titles and...

Page 14: ...mplete The existing TC 200 settings should persist through the firmware upgrade process which should not be interrupted once started as this could result in a non responsive unit Successful firmware u...

Page 15: ...15 3 Before running the Flash Update software please set the TC 200 DIP SW 6 to 1 DOWN 4 Run FlashUpdate_x xx exe and click Next...

Page 16: ...16 5 Select Device is connected via Ethernet and click Next...

Page 17: ...re version then click NEXT 7 Click Yes button to confirm you wish to perform the firmware update when you see the prompt window Do you really want to perform firmware update 8 The update process will...

Page 18: ...se Input Format 1920 x 1080i 50Hz 1920 x 1080i 60Hz 1920 x 1080i 59Hz 1920 x 1080i 60Hz instead 1920 x 1080i 59Hz 1280 x 720p 50Hz 1280 x 720p 60Hz 1280 x 720p 59Hz 1280 x 720p 60Hz instead 1280 x 720...

Page 19: ...19 Notes...

Page 20: ...www datavideo com product TC 200 May 08 2020 Ver E5 Datavideo Technologies Co Ltd All rights reserved 2020...

Reviews: