Network Configuration
The D-100 Host has a serial port on the front panel which is used to configure network settings
and security options. A dumb terminal or terminal emulation software is required to get online and
set up the configuration. The port is male DTE, so you will need to use a null modem cable.
Terminal communication settings must be set to:
9600 baud, no parity, 8 data bits, 1 stop bit
To get online with the D-100, connect your terminal to the serial port and press <RETURN>.
A menu will appear which will guide you through the setup.
Datas D-100 Host Unit V1.0.0.0
Enter Password ()>
{The DEFAULT
PASSWORD
for a New Unit is “ims4k”}
1. Display Enterprise status
2. Display Network and Option configuration
3. Configure Network settings
4. Configure Enterprise Name
5. Configure Web Server
6. Configure Remote Access Server
7. Enable Two-Way E-mail Responder
8. Enable Microphone Listen-In
9. Enable default Master Administrator Account (temporarily)
0. Enable data modem
A. Change Admin Password
B. Reset To Factory Defaults
C. Display Statistics
D. Reboot
E. Logout
Enter option->
If you select Option 1 you will see the IP address and status of the Host and all associated nodes.
A sample is shown below:
Enterprise Status
Unit
Type IP
Status
D-100 Monitor
Host 10.1.4.10
Ok
NY_Node
Node 10.1.4.17
Ok
Press any key to return to main menu
Option 2 will display the network configuration for the Host as well as web server, RAS, and two-
way email settings. A sample of Option 2 is shown below:
Installation Manual
18
Summary of Contents for Node 4000
Page 1: ...Installation Manual for Host Node Units Version 1 2 DATAS TECHNOLOGY LTD i...
Page 6: ...Installation Manual vi...
Page 9: ...IMS 4000 Host Installation...
Page 24: ...Installation Manual 24...
Page 26: ...Installation Manual 26...
Page 27: ...4000 Node Installation 27 Node...
Page 38: ...Installation Manual 38...
Page 40: ...Installation Manual 40...