V180808N
T-APS Users Manual
Page 9
1E-3 = 1 x 10
-3
Once the Line Code Violation Error Ratio exceeds the preset threshold value, it will then switch the ACTIVE
PATH to the PROTECTION PATH.
D: SET LCV CLEAR RATIO
Set Line Code Violation Error Ratio
Selections:
1E-9 = 1 x 10
-9
1E-8 = 1 x 10
-8
1E-7 = 1 x 10
-7
1E-6 = 1 x 10
-6
1E-5 = 1 x 10
-5
Once the Line Code Violation Clear Ratio achieves the preset threshold value, it will then switch back from
PROTECTION PATH to the ACTIVE PATH.
E: SET FRAME ALARM RATIO
Selections:
1E-5 = 1 x 10
-5
1E-4 = 1 x 10
-4
1E-3 = 1 x 10
-3
1E-2 = 1 x 10
-2
1E-1 = 1 x 10
-1
Once the Line Code Violation Error Ratio exceeds the preset threshold value, it will then switch the ACTIVE
PATH to the PROTECTION PATH.
F: SET FRAME CLEAR RATIO
Selections:
1E-7 = 1 x 10
-7
5E-6 = 5 x 10
-6
1E-5 = 1 x 10
-5
1E-4 = 1 x 10
-4
1E-3 = 1 x 10
-3
Once the Line Code Violation Clear Ratio achieves the preset threshold value, it will then switch back from
PROTECTION PATH to the ACTIVE PATH.