Serial iBootBar  v

090212d 

   

 

 

 

 

 

Specifications 

 
 
Physical: 

Height:  

1U  1.75 in (4.5 cm)   

Width:  

19.0 in (48.25 cm) 

Depth:  

6.00 in (15.25 cm) 

Weight:  

7 lbs (3.25 Kg) 

 

 
Environmental: 

Temperature 

 

Operating: 

0 to 40

o

 C 

Storage: 

-10 to 85

o

 C 

Relative 
Humidity  

0 to 95%  
Non-
Condensing 

 
 

Input Required 

Model 

Input 

Output 

Control 

sBB-N15 

N15 

8 x N15 

I, S,  

 

sBB-N15-M 

N15 

8 x N15 

I, S, M 

sBB-2N15 

2 x N15 

8 x N15 

I, S, L 

 

sBB-2N15-M 

2 x N15 

8 x N15 

I, S, M 

sBB-N20 

N20 

8 x N15 

I, S 

 

sBB-N20-M 

N20 

8 x N15 

I, S, M 

sBB-2N20 

2 x N20 

8 x N15 

I, S 

 

sBB-2N20-M 

2 x N20 

8 x N15 

I, S, M 

sBB-C10 

C14 

8 x  C13 

I, S 

 

sBB-C10-M 

C14 

8 x  C13 

I, S, M 

sBB-2C10 

2 x  C14 

8 x  C13 

I, S 

 

sBB-2C10-M 

2 x  C14 

8 x  C13 

I, S, M 

sBB-C20 

C20 

8 x  C13 

I, S 

 

sBB-C20-M 

C20 

8 x  C13 

I, S, M 

sBB-2C20 

2 x  C20 

8 x  C13 

I, S 

 

sBB-2C20-M 

2 x  C20 

8 x  C13 

I, S, M 

 
Key: 

Input:  

N15  

NEMA 5-15 Linecord 115VAC 15 Amps combined total switched 

 

N20  

NEMA 5-20 Linecord 115VAC 20 Amps combined total switched 

 

C14  

IEC320 C14 Receptacle 100-240VAC 10 Amps total at 240VAC Max 

 

C20 

IEC320 C20 Receptacle 100-240VAC 20 Amps total at 240VAC Max 

 

Outlet: 

N15  

NEMA 5-15 Receptacle 115VAC 12 Amps Max 

 

C13 

IEC 320 C13 Receptacle 100-240VAC 10 Amps Max 

 

Summary of Contents for sBB-N15

Page 1: ...via RS 232 serial communications and via contact closure inputs The following models are covered in this document Model Power Feed Total Capacity Outlets sBB N15 NEMA 15 Amp 8 x NEMA 5 15 sBB 2N15 2 x...

Page 2: ......

Page 3: ...Instructions 4 Quick Start 5 General Overview 6 Installation 7 Rack Mounting Serial Port Contact Closure Inputs Power Source Serial Operation 9 Control Input Operation 14 Advanced Operation 15 Specif...

Page 4: ...the grounding type plug Do not use a 3 to 2 prong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to res...

Page 5: ...t status iBootBar get outlets To turn on off outlet 1 iBootBar set outlet 1 off To reboot outlet 2 iBootBar set outlet 2 cycle Outlet Status Indicators Reset Pushbutton Recessed Mains Inlet Power Indi...

Page 6: ...models Models with dual inputs sBB 2N or sBB 2C have two inlets mains Each main feeds four outlets Inlet A supports outlets 1 4 and Inlet B feeds 5 8 Dual power inlet models can be used to support hig...

Page 7: ...outlets using contact closure contact open connections Each connection marked 1 through 8 controls the outlet of the same number The remaining 8 connections are ground and are interchangeable Using a...

Page 8: ...Page 8 Serial iBootBar v090212d Expansion Future Expansion No function in the current Serial iBootBar...

Page 9: ...al applications and can be used on 100V to 240VAC The sBB 2C10 provides two IEC 320 style universal inlets for connecting a detachable power cord Two standard IEC to CEE7 European cord sets are suppli...

Page 10: ...must have rights to the selected outlet User set outlet 1 8 on off cycle Sets the selected outlet to the selected state The user must have rights to the selected outlet User set outlet 1 8 name name S...

Page 11: ...Add user rights to outlets and groups Admin del user username Deletes the selected user from the root iBootBar s user table Admin ren user username newname Renames the selected user in the root iBootB...

Page 12: ...ff during a reboot on off on or on during a cycle off on off User 10 get delay set delay 0 99 Get or set the delay time in seconds When multiple outlets are turned On by a single command this delay co...

Page 13: ...in 120 set console baudrate 2400 4800 9600 19200 38400 57600 115200 The baud rate of the serial port 400 4800 9600 19200 38400 57600 115200 bps Admin 115200 set factory defaults Resets all parameters...

Page 14: ...s or deletes a specific outlet on a specific device from the selected group Admin ren group groupname newname Renames the selected group 20 characters max Admin del group groupname Deletes the selecte...

Page 15: ...y switch or relay closures or open collector relay drivers to connect to the sBB inputs If you have any doubts about proper connections consult Dataprobe Technical support The default control is Input...

Page 16: ...es will be formatted as follows cr lf device name outlet outlet name control type source cr lf Where cr ASCII carriage return lf ASCII line feed character device name User programmed name of the sBB o...

Page 17: ...load the latest version of the firmware and upgrade utility from the Dataprobe website Password Recovery Holding the reset button on the front panel of the iBootBar for 5 seconds or longer will initia...

Page 18: ...I S M sBB 2N20 2 x N20 8 x N15 I S sBB 2N20 M 2 x N20 8 x N15 I S M sBB C10 C14 8 x C13 I S sBB C10 M C14 8 x C13 I S M sBB 2C10 2 x C14 8 x C13 I S sBB 2C10 M 2 x C14 8 x C13 I S M sBB C20 C20 8 x C1...

Page 19: ...ies with Part 15 of the FCC rules Operation of this device is subject to the following conditions 1 This device may not cause harmful interference and 2 this device must accept any interference that m...

Page 20: ...Technical Service at 201 934 5111 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shi...

Reviews: