iPAL  Page 12 

Telnet Operation 

 
Access for operation via telnet is the same as access for configuration.   
 

Location 
 
Mode = 6                  Status   Feedback 
 
1.  Outlet 1               ON      OK 
2.  Outlet 2               ON       OK  
3.  Outlet 3               ON         OK 
4.  Outlet 4               ON       OK 
5.  Outlet 5               ON   OK  
6.  Outlet 6               ON   OK  
7.  Outlet 7               ON   OK  
8.  Outlet 8               ON   OK  
 
#  - Select relay to toggle or A for All 
P# - Pulse relay 
S  - Setup 
X  - Exit 
 
Enter > 

 
 
The screen shows the current status of all power outlets. 
To change the status of any outlet, type the outlet number and <Enter> at the prompt. 
 
You can change all circuits simultaneously by selecting A and <Enter> for All. 
 
The feedback column confirms that the switch command you selected has been carried out.  If this column reads "ERROR" 
check the unit or the external cables to any expansion unit.  Switching outlets 5-8 without an attached power switch will cause 
this error. 
 
To momentarily pulse (cycle) the status of an outlet, for power reboot, enter P and the outlet number plus <Enter>  The status 
will change while the outlet is cycling.  The duration of the pulse is determined in the setup.  The default is 10 seconds. 
All circuits can simultaneously be cycled by selecting PA <Enter>. 

Summary of Contents for IP-410 -

Page 1: ...ed outlets for use on 115 VAC 15 Amp Service NEMA N5 15 iP 810 8 switched outlets for use on 115 230 VAC 12 10 Amp International IEC 320 iP 410 4 switched outlets for use on 115 230 VAC 12 10 Amp Inte...

Page 2: ...se a 3 to 2 prong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to rest on the power cord Do not locat...

Page 3: ...115VAC 10base T J2 Serial J1 Expansion J3 Model iP 420 M iP 415 M 8 NEMA 5 15 Outlets 115VAC 10base T J2 Internal Modem J1 Expansion J3 Model iP 810 8 IEC320 Outlets 115 230VAC 10base T J2 Serial J1...

Page 4: ...directly to a laptop or terminal requires a null modem crossover cable With a terminal directly installed a simple menu interface is used These menus are identical to the telnet setup and control scr...

Page 5: ...upport tech dataprobe com or 201 967 8788 A C Power Connections The iP 820 iP 420 provide a linecord for connection to a 20 Amp 115VAC service The total maximum current load for all outlets on the iP...

Page 6: ...the following command arp s IP Address MAC Address Where IP Address is the desired IP address for the iPAL and the MAC address is the MAC Address of the iPAL The MAC Address of the iPAL is located on...

Page 7: ...A Using Make a New Connection in Dial up Networking setup a Dial Up Networking connection Set the desired modem and telephone number you wish to use Now right click and choose properties of the Dial u...

Page 8: ...ing icon you have just created No user name or password is required Click on Connect B Once a Dial Up Networking connection has been established you can access the iPAL using any telnet A web browser...

Page 9: ...r re set to factory defaults should they become inadvertently changed The iPAL system is capable of controlling up to eight outlets Model s iP 410 and iP 415 provide only four outlets with room for ex...

Page 10: ...me 10 X Return to the Main Menu Enter Circuit Names For All Models Each circuit outlet can be identified with a 20 character name for easy identification Select 1 from the Setup menu A list of all eig...

Page 11: ...password required for Telnet and Web Browser Access To change the password Select 4 from the Setup Menu The password can be up to 8 characters and is case sensitive Please remember your password If yo...

Page 12: ...and Enter at the prompt You can change all circuits simultaneously by selecting A and Enter for All The feedback column confirms that the switch command you selected has been carried out If this colu...

Page 13: ...onfiguration Remember the password is case sensitive When the password is properly entered click OK This brings up the Control and Status screen This screen provides all the control and status informa...

Page 14: ...iPAL Page 14 Upon completion of your control session click on logout This will terminate the session and release iPAL to the next user The Goodbye page will be displayed...

Page 15: ...le 16 Amps combined total of all receptacles iP 815 iP 415 Main Power Input Standard NEMA 5 15 Plug on 6 foot 14 3 line cord 120VAC Output Circuits Standard NEMA 5 15 Receptacle Current Maximums 12 Am...

Page 16: ...01 967 8788 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shipment THIS WARRANTY DO...

Reviews: