background image

    

More Power Control Solutions  

8 Outlet Remote Control Power Strips 

 

Rack Mounted 8 outlet power strips can be controlled by Web / Telnet / Modem / 
Serial or DTMF dialing tones.  Visit 

www.dataprobe.com/power/8outlets.html 

Phone Controlled  Power Switch 

 

PowerPAL offers remote control of a 
single A/C outlet using any tone dial 
telephone. PowerPAL connects to an 
existing dial line, and any telephone 
equipment; phone, fax, modem. 
Normal calls pass transparently 
through PowerPAL; only when 
special access codes are detected by 
PAL will the power control functions 
be enabled. User selectable security, 
call processing and power control 
features are examples of such 
capabilities.  Visit 

www.dataprobe.com/power/ppal.html

 

Remote Power C Console Port Access 

 

 
Access four console ports and reboot four devices with this integrated Remote Site 
Manager. From one call you can switch between any of the four serial ports or access 
any of the A/C outlets for complete access and control. The internal modem option 
turns this unit into a completely integrated system that will minimize costly trips to 
remote sites.

  

Visit www.dataprobe.com/power/4pk415.html 

 
 
 
 

 

11 Park Place 
Paramus, NJ 07652 
201-967-9300 

www.dataprobe.com 
[email protected]  

Doc: iBoot15c_021009e 

    

© 2002  Dataprobe, Inc.  All rights reserved 

Summary of Contents for iBoot

Page 1: ...n 9 Setting IP Address Using DHCP Using Web Browser Access Using ibootrst exe Using ARP Ping Web Browser Operation 12 Password Protection Control Status Page Setup Page Passwords Page Forgotten Passwo...

Page 2: ...ong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to rest on the power cord Do not locate this product...

Page 3: ...ps 10 Amps at 230VAC Uses for iBoot Remote reboot of any device routers servers kiosks etc The device to be rebooted need not be network attached Secure sensitive devices by keeping them powered off w...

Page 4: ...reboot it automatically when it no longer responds Use Auto Ping Remotely Put iBoot at a central facility to monitor a remote system and power up an alert when the remote device no longer responds Up...

Page 5: ...disconnect the iBoot from the AC power source before making any control connections 10 100 Ethernet Power Input IEC 320 Male Line Cord Incuded for North America Power Input Selector 115 230 VAC Power...

Page 6: ...ovided Use the Uplink jack to connect to an Ethernet hub and the Downlink jack to connect to an additional piece of networking equipment An LED next to each indicates when the connection to the networ...

Page 7: ...Connect to Power Source Use Included Cord for North America For other locations use locally approved power cord 1 2 3 Connect Powered Device Use either IEC to NEMA Extension Cord supplied OR IEC to IE...

Page 8: ...device to be power controlled The iBoot can be connected to a power strip to allow simultaneous control of multiple devices Make sure that the combined load of all controlled devices does not exceed 1...

Page 9: ...et Mask and Gateway to the iBoot If you power up iBoot without a fixed static IP address the DHCP server will be able to assign an IP address This is the factory default setting for iBoot Once an IP a...

Page 10: ...r ibootrst exe For iboot exe http www dataprobe com files power iboot exe To use ibootrst exe the computer running the program must be on the same subnet and network segment as the iBoot is to be prog...

Page 11: ...d the MAC address is the MAC Address of the iBoot The MAC Address of the iBoot is located on bottom of the unit Example arp s 63 211 86 165 00 50 c2 05 01 c1 enter new IP addr MAC addr 3 Ping the iBoo...

Page 12: ...rd if it has been changed A Username is not required When the proper password is received the Control and Status Page is displayed Control and Status Page Once the password is entered the following pa...

Page 13: ...dow without first clicking Logout there will be a two minute delay before you can re access iBoot iBoot uses an inactivity timer for security When there is no activity for 2 minutes the user is logged...

Page 14: ...he top of the page The new IP address will not take effect until the unit is rebooted Subnet Mask Change if required Consult your network manager for more details This will be automatically set if usi...

Page 15: ...on When the ping response returns iBoot will power off Power Off Latch Upon loss of ping response iBoot will power off and remain so until changed via the web ibootctl exe or direct messaging Power Of...

Page 16: ...for each password being changed OOPS I forgot my Password Well we told you to remember it but we understand You can reset iBoot to its factory default conditions Dataprobe provides a iBoot Reset Progr...

Page 17: ...r ibootctl exe or http www dataprobe com files power iboot exe for ibootctl exe and ibootrst exe the reset program Direct TCP Telnet Control For application developers iBoot also supports control via...

Page 18: ...Input 3 Prong Male IEC 320 input connector Input Cord Spec 16AWGX3C 10A 250 UL CSA VDE Rated 1 25mm 2 X3C Voltage Range Selectable 115 or 230 VAC Switched Receptacle 3 Prong Female IEC Capacity 12 Amp...

Page 19: ...al Service at 201 967 8788 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shipment T...

Page 20: ...functions be enabled User selectable security call processing and power control features are examples of such capabilities Visit www dataprobe com power ppal html Remote Power Control Console Port Ac...