 Setup 

 
The Setup button from the Home page provides access to all the configuration of the COE-8.  The 
Setup area is divided into several pages: 
 

Device Page:   

Basic setup of the COE-8, IP address and TCP/IP settings 
 
Name   

 

Assign a name up to 20 characters to help identify the COE-8 

 
IP Address    Set the IP Address manually in the Static Mode (see below) 
 
IP Modes   

Set the method to configure the IP address.   See section above for details.  

§

  Static: Manually entered IP address information 

§

  DHCP:  IP address obtained upon power up from DHCP server. 

 
Port Settings  The IP Setup page also allows for changing of the port assignment for both the Control 
communication and web page access.   Dataprobe recommends changing the Web port for units that 
will be connected to the Internet.  This will minimize the number of hacker attacks that the COE-8 will be 
subject to. 
 
The Control Port for both the COE-8

I

 and all COE-8Os that receive status from it must be set the 

same. 
 
If a port other than the default Port 80 is used for web browser access, that port must specifically be 
used in the URL when accessing the COE-8.  For example, if the Web Port is changed to 9090 then the 
URL for the unit would be http://192.168.1.254:9090 
 

Receivers  (COE-8

I

 Only) 

 

Transmission Frequency

  0 to 9999 seconds 

This sets the frequency that the COE-8

I

 transmits its status to the receivers.  When set to 0, 

transmission will only occur upon change of status. 

Receiver IP Address  

Set up to 32 IP addresses of the COE-8O units that will have input status 

information set to them.  If you wish to send the same input channel status to two different channels on 
any one COE-8O, then that IP address must be entered twice in the table.

 

 

Inputs (COE-8

I

 Only) 

The COE-8I can send individual input status to multiple COE-8O receivers, or other IP address.  This 
page provides for selecting which output of the COE-8Os will be operated by each input of the COE-8I.  
Select the Input from the drop down box, then configure the Name for that input, along with the channel 
of each COE-8O unit to receive the status.  Click Apply after each channel is configured. 
Use Output 0 if no output of a given COE-8O is to be used for that channel.  Configure each of the 8 
inputs as necessary. 

Summary of Contents for COE-8

Page 1: ...O has eight relays that will mirror the status of the eight inputs of the COE 8I Each unit can be monitored and configured from a Web Browser Each channel of the COE 8I is independently configurable a...

Page 2: ...DC Maximum Carrying Current 2 A Maximum Switching Power 60 AV 24 W Maximum Switching Voltage 120 VAC 60 VDC Maximum Switching Current 1A Life Expectancy 5 Million Operations Mechanical 100K Operations...

Page 3: ...p the COE 8 units WEB Page Access The web pages provide status information on the inputs and outputs of the COE 8 as well as provide configuration for the unit Open a browser to the default or current...

Page 4: ...Subnet Mask and Gateway as provided by your network administrator Click Apply to save the changes You will then be prompted to reboot the COE 8 Click on the Reboot button The COE 8 will reboot and the...

Page 5: ...for web browser access that port must specifically be used in the URL when accessing the COE 8 For example if the Web Port is changed to 9090 then the URL for the unit would be http 192 168 1 254 9090...

Page 6: ...there is a change of state on any COE 8 channel Check the box provided to enable this If both the COE 8I and COE 8O are configured to send traps two messages will be received by each SNMP manager for...

Page 7: ...967 8788 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shipment THIS WARRANTY DOES...

Reviews: