Select “dLOF” from the parameter menu to set DELAY OFF function. 
The parameter programming is accessed by pressing 

The previously set delay value appears on the display. 

Pressing 

 or 

 the delay value is increased or decreased by one step of 

1 ms until a maximum delay of 100ms. Keeping press 

 

or

 

 the delay 

value is increased or decreased by incremental step. The setting of a delay 
different from zero is signalled by the DELAY LED on. Press 

 to confirm 

the value and return to the parameter menu. 

PNP/NPN output setting 

The digital output can be configured as PNP or NPN. 
Select ‘_PnP’ or ‘_nPn’ in the parameter menu to switch the output. 

The previously set output switches by pressing 

UP/DOWN DISPLAY setting 

The selection of the UP/DOWN display sets the reading direction on the 
display.  
Select “dSUP” or “dSdn” in the parameter menu to set the UP or DOWN 
direction. 

Press 

 to switch the reading direction previously set

. 

ON/OFF DISPLAY setting 

Turn off the display during normally working to save power consumption.  
Setting the OFF mode, when the sensor is functioning normally, the display is 
OFF. It turns on for 5s after a keyboard command. Select “dSOn” or “dSOF” 
in the parameter menu to set the display ON or OFF.  

Press 

 to switch the display mode previously set. 

RESET of default parameters 

Select “rSEt” in the parameter menu to reset the default parameters. 

The “rSEt” text blinks when pressing 

Releasing the push-button the sensor returns to normal functioning. 
The default reset parameters are: 

PARAMETER

DISPLAY

DESCRIPTION

Emission 

________ 

Green 

 DARK/LIGHT mode 

________ 

Light 

Threshold 

2050 

 

Hysteresis 

Medium (Normal)

 

Delay ON and OFF 

Deactivated

 

Digital output 

PNP output 

Display 

Display UP ON 

 

NOTE: if the parameters are reset before turning the sensor off,  when 
repowered the “rSEt” text blinks on the display for 3s before returning 
to normal visualisation. 

Saving parameter set  - “SAVE” 

Select “SAVE” to save the parameter setting  

The parameters are saved pressing 

 and releasing it the display returns to 

normal visualisation. 

NOTE: Set the data, the operator exits from the menu using the “SAVE” 
or “RESET” function. If these operations are not carried-out 30s after 
the last setting, the sensor returns to normal mode saving the 
parameters changed. 

ACCESSORY FUNCTIONS 

REMOTE INPUT 

The REMOTE signals carries-out the acquisition functions without using the 

 push-button. 

The REMOTE wire connected to +Vdc is equal to pressing the 

 push-

button. Whereas, if the REMOTE wire is connected to GND or not connected 
it is equal to not pressing the 

 push-button. 

REMOTE 

 PUSH-BUTTON 

0V 

NOT PRESSED 

+Vdc 

PRESSED 

-

 

The duration of the REMOTE wire connection to +Vdc determines the 
acquisition type: 

 

DARK/LIGHT input 

The DARK/LIGHT signal allows the operator to select the DARK/LIGHT 
operating mode for dynamic detection.  
In the LIGHT mode the output is active with light marks on dark backgrounds, 
in the DARK mode the output is active with dark marks on light backgrounds. 
The connection of the DARK/LIGHT wire to Vdc sets the DARK mode. 
If connected to 0V or not connected set the LIGHT mode. 

DARK/LIGHT

MODE 

0V 

LIGHT 

+Vdc 

DARK 

EX-

II

-3DG IP67 T6 

Temperature class: 

T6 (<85°C) 

Max. Power consumption 1000 mW at 30 Vdc 
Max. Internal capacitance 100 nF 
Internal inductance: 

negligible 

DECLARATION OF CONFORMITY 

We DATALOGIC AUTOMATION declare under our sole responsibility that these products are conform 
to the 2004/108/CE and successive amendments. 

 

WARRANTY

 

DATALOGIC AUTOMATION warrants its products to be free from defects. 
DATALOGIC AUTOMATION will repair or replace, free of charge, any product found to be defective 
during the warranty period of 36 months from the manufacturing date. 
This warranty does not cover damage or liability deriving from the improper application of DATALOGIC 
AUTOMATION products. 

 

 

DATALOGIC AUTOMATION cares for the environment: 100% recycled paper. 
DATALOGIC AUTOMATION reserves the right to make modifications and improvements without prior notification.

 

Datalogic and the Datalogic logo are registered  trademarks of Datalogic S.p.A. in many countries, 

including the U.S.A. and the E.U. 

826003103

 

Rev.C

 

© Copyright Datalogic 2007-2012 

DYNAMIC 

DET. 

Mark detection 

V

cc

 

REMOTE

 

GND

>1s

Background detection 

REMOTE

 

GND

 

4s 

V

cc

 

Dynamic detection 

(begin) start 

STATIC 

DET. 

Dynamic detection  

end 