RAPID CONFIGURATION
6 SMART-VS
Button Re-Teaching Procedure (optional)
When in Run mode (Run green LED steady on), the current job can be erased and re-
trained.
Long-press (> 4s, until the red LED on HMI lights up) the HMI Button to enter the Teach-
ing procedure, then follow the "
Button Teaching Procedure" on page 4
If errors occur and the new Teaching is not finalized, the current job will not be over-
written.
NOTE
3. Long press (> 4s, until the red LED on HMI
lights up) the HMI Button to start acquiring
NO GOOD objects. Red LED and red spot start
blinking.
4. New NO GOOD object images can be added to
the current job.
If incremental teaching is needed for GOOD
objects only, skip to step 5.
Short press (< 1s) the HMI Button to acquire
the NO GOOD image.
5. Long press (> 4s, until the red LED on HMI
lights up) the HMI Button to enter the auto-
matic learning procedure (LEDs game). In the
end, the device will enter the Run phase.
NOTE
In case of mistakes, the procedure can be aborted before proceeding to
step 5 by pressing the HMI Button for approx. 2 seconds until the HMI yel-
low LED turns on.
In case of mistakes, the procedure can be aborted before entering the
learning procedure by pressing the HMI Button for approx. 2 seconds until
the HMI yellow LED turns on.