50
6.7.3 Override restart mode function
This function let the user choose, setting dip-switches of RX device (see section 5
”), the restart mode after Override when ESPE is configured in
manual restart mode, and in particular to force automatic restart mode of light curtain as shown in Figure 47.
SAFE
NORMAL
OPERATION
OFF
ON
Forced
condition
FREE
OBSCURED
OVERRIDE STATUS
OSSDs
BEAMS
Figure 47
Override with automatic restart function, allows to restart automatically the normal
working of the curtain (normal operation condition) when the detection area (curtains +
sensors) is cleared.
This function does not comply with the requirements of IEC 61496-1, because it is a forcing of the safety
condition.
For this reason, all possible risks must be considered and related precautions undertaken.
It is recommended that:
•
all control operations must be assigned only to a well-trained and skilled personnel;
•
the user assigned to the actuation of the override function, must be able to work in a
condition of maximum surveillance and visibility of the whole area.
6.7.4 Override status
When the device enters the Override status, OVERRIDE STATUS PNP output line provided on M12 12 RX
connector (see section 5
– “ELECTRICAL CONNECTIONS AND CONFIGURATION”) switches from 0Vdc to
24Vdc, providing electronic information to the user.
OVERRIDE STATUS
OVERRIDE STATUS
PNP OUTPUT
0Vdc
24Vdc
OFF
ON
Figure 48
Summary of Contents for SG4-RB2-050-OO-N
Page 1: ......
Page 3: ......
Page 7: ......
Page 73: ...66 SG4 RB2 3L SG4 RDB2 3L ...
Page 74: ...SG BODY REFLECTOR MUTING 67 SG4 RB2 3T SG4 RDB2 3T ...
Page 91: ...84 ACTIVE PASSIVE ...
Page 92: ...SG BODY REFLECTOR MUTING 85 ACTIVE PASSIVE ...
Page 95: ...88 ...