SG BODY REFLECTOR MUTING
39
Next picture shows an example of Muting functioning:
a)
b)
c)
d)
e)
f)
6.6.1 Muting T/L selection function
This function let the user select the requested configuration for muting sensors, and can be set by dip-
switches of RX device (see section 5
– “ELECTRICAL CONNECTIONS AND CONFIGURATION”).
Temporal diagram of the Muting function for two-
sensor configuration (“L-shaped” or crossed-beam versions)
MUTING1
0Vdc
24Vdc
t
AB
MUTING2
MUTING STATUS
0Vdc
24Vdc
OFF
(ESPE normal
operation)
ON
t
Moff
As shown in the previous picture, tAB indicates the interval of time between MUTING1 and MUTING2
activation (see paragraph 6.6.4 - "Installation mode of Muting sensors
”). After a tMoff interval of time
between deactivation of MUTING1, light curtain exits the muting status and returns in normal operation (see
paragraph 6.6.4 - "Installation mode of Muting sensors
Summary of Contents for SG4-RB2-050-OO-N
Page 1: ......
Page 3: ......
Page 7: ......
Page 73: ...66 SG4 RB2 3L SG4 RDB2 3L ...
Page 74: ...SG BODY REFLECTOR MUTING 67 SG4 RB2 3T SG4 RDB2 3T ...
Page 91: ...84 ACTIVE PASSIVE ...
Page 92: ...SG BODY REFLECTOR MUTING 85 ACTIVE PASSIVE ...
Page 95: ...88 ...