For SG4 FIELDBUS Series light curtain different description files are available depending on specific light curtain model, 
please refer to table below: 
 

Model 

Length (mm) 

Description Files 

Base 
(SG4-xx-xxx-OP-B)

 

150-1800 

FFFF000D-SG4-x-x-OP-B.xdd 
SG4-x-x-OP-B.xosdd 

Advanced up to 600mm 
(SG4-xx-xxx-OP-A) 

150-600 

FFFF000D-SG4-14_30-15_60-OP-A.xdd 
SG4-14_30-15_60-OP-A.xosdd 

Advanced from 750mm to 1800mm 
(SG4-xx-xxx-OP-A) 

750-1800 

FFFF000D-SG4-14_30-75_180-OP-A.xdd 
SG4-14_30-75_180-OP-A.xosdd 

 

 

2.  Select first the file with extension .xosdd related to the device you want to import. 

 

 

Step 2 - Importing the device

 

 

3.  Select the file with extension .xdd according to the one selected above. 

 

 

Step 3 - Importing the device

 

 

Summary of Contents for SG4 FIELDBUS Series

Page 1: ...ns for the correct functioning before powering the light curtain Precautions to be observed for the choice and installation of the device Make sure that the protection level assured by the SG4 device...

Page 2: ...CONNECTOR 1 24VDC BROWN 2 NOT USED WHITE 3 0 VDC BLUE 4 NOT USED BLACK CN2 SIGNAL ETHERNET POWERLINK PORT1 1 TxD transmit data 2 RxD receive data 3 TxD transmit data 4 RxD receive data CN3 SIGNAL ETH...

Page 3: ...dard installation described hereinafter is the one shown in figure with the bar assembled with the connectors pointing down Two yellow LEDs LAST SYNC on receiver unit facilitate the alignment procedur...

Page 4: ...ly using brackets Verify that the green LED on the RX unit is ON and beams are not interrupted then verify that the red LED turns ON if even one single beam is interrupted condition where an object ha...

Page 5: ...OP B xosdd Advanced up to 600mm SG4 xx xxx OP A 150 600 FFFF000D SG4 14_30 15_60 OP A xdd SG4 14_30 15_60 OP A xosdd Advanced from 750mm to 1800mm SG4 xx xxx OP A 750 1800 FFFF000D SG4 14_30 75_180 OP...

Page 6: ...click on SG4 FIELDBUS device and select Change node number set the address from 1 to 240 Select EPL device address in AutomationStudio On device choose same address by setting the two rotary switches...

Page 7: ...ot aligned M Red MASTER uP STATUS OFF Normal operation Blinking ON Error ON uP MASTER Boot Pre op S Red SLAVE uP STATUS see LED S ON Error ON uP SLAVE P Red Green ETHERNET POWERLINK STATUS Green ON no...

Page 8: ...t regarding the final installation Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measure...