![Datalogic SG4-14-015-OO-E Instruction Manual Download Page 45](http://html.mh-extra.com/html/datalogic/sg4-14-015-oo-e/sg4-14-015-oo-e_instruction-manual_512614045.webp)
SG4 BASE
45/74
For Emitter:
Function
State
Meaning
LED
DIGIT
Normal operation
TEST
(green ON)
Light curtain being tested. OSSD status on
the receiver must be OFF
Emission
(green ON yellow
ON)
Light curtain in normal operating condition
Function
Type
Check and repair
LED
DIGIT
Error status
Internal error
(green ON)
Switch OFF and switch ON the power supply
circuit.
If the failure continues contact DATALOGIC.
Optical error
(green ON)
Switch OFF and switch ON the power supply
circuit.
If the failure continues contact DATALOGIC.
No power supply
(LEDs OFF)
Check connections and input voltage correct
value.
If the failure continues contact DATALOGIC.