background image

SG-PSB INSTRUCTION MANUAL 

6  

 

SG-DM DEVIATING MIRRORS MOUNTING 

 
Using the ST-PS-DM kit, mount the carter for the deviating mirror in use. Make 
sure that the M8 T-nut is aligned with the corresponding central groove of the 
protective stand and that the side edges of the mirror's carter are aligned with 
the corresponding longitudinal guides in the protective stand (Fig. 6). Adjust 
the height of the protective stand then tighten the M8 x 50 UNI5931 screws. 
 
Tighten the M8 UNI 5588 nut under the carter eyelet to avoid accidental 
unfastening. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig. 6 

 
 

SG-P ACCESSORY MOUNTING 

 
Fasten the plate to the floor with the screws and insert the 3 load-bearing springs on the 
spacers on the plate. Place the column on the springs so that the slots in the bottom plate 
are aligned with the springs. Insert the M10 UNI 5931 screws and washers, provided with the 
SG-P accessory, in the slots and tighten them while gradually pressing down upon the 3 
load-bearing springs. During this phase the vertical axis can also be adjusted. Use as a 
reference the spheric level and choose the rough angular position using the slots and the 
reference marks on the bottom plate. The optimal working height for the load-bearing springs 
(which corresponds to the distance between the fixed plate and the bottom plate) is 
approximately 42 mm. Once it rests on a level surface and the maximum angular position 
has been established, it is possible to perform a fine adjustment of the angular position by 
working on the dowels and the lock nuts of the moulded plate (Fig. 7). 
 

 

Fig. 7 

T-nut in central guide 

Side guides 

Summary of Contents for SG-PSB Series

Page 1: ...SG PSB Safety light curtain protective armor stand Instruction Manual Fig A 826000200 Rev 00...

Page 2: ...ts the light curtain mounted inside it from accidental collisions Single painted drawn aluminium section in different lengths suitable for all heights of the following series SE SG2 SG4 150 1800 mm SE...

Page 3: ...on of light curtains of the SG Body Big series body protection protected height 500 800 900mm ST PS6 SG Body 95ASE1740 for the installation of light curtains of the SG Body Big series body protection...

Page 4: ...ION MANUAL 4 Fig 2 Once the assembly is completed remove the column cover by unscrewing the two M8x20 ISO 7380 screws Fig 3 and insert the assembly in the internal guides Fig 3 Tighten partially leave...

Page 5: ...5x8 UNI 5931 screws which can be accessed from the outside by using a special Allen key if the column is in a vertical position make sure the product does not slide accidentally towards the bottom Fig...

Page 6: ...e the column on the springs so that the slots in the bottom plate are aligned with the springs Insert the M10 UNI 5931 screws and washers provided with the SG P accessory in the slots and tighten them...

Page 7: ...the 3 slots on the bottom plate and M10 screws Do not tighten the M10 screws completely Unfasten the lock nuts on the dowels then use the dowels to adjust the inclination during this operation use the...

Page 8: ...to fine adjust their inclination if necessary 4 Orient the mirrors to about 45 with respect to the optic path the Protective stand guarantees an adjustment interval around the vertical axis of about 5...

Page 9: ...BLE MODELS SG PSB MODEL DESCRIPTION ORDER No SG PSB 600 Protective Stand H 600 mm 95ASE2240 SG PSB 1000 Protective Stand H 1000 mm 95ASE2250 SG PSB 1200 Protective Stand H 1200 mm 95ASE2260 SG PSB 165...

Page 10: ...ng the warranty period of 36 months from the manufacturing date This warranty does not cover damage or liability deriving from the improper application of DATALOGIC AUTOMATION products DATALOGIC AUTOM...