SG-PSB INSTRUCTION MANUAL
6
SG-DM DEVIATING MIRRORS MOUNTING
Using the ST-PS-DM kit, mount the carter for the deviating mirror in use. Make
sure that the M8 T-nut is aligned with the corresponding central groove of the
protective stand and that the side edges of the mirror's carter are aligned with
the corresponding longitudinal guides in the protective stand (Fig. 6). Adjust
the height of the protective stand then tighten the M8 x 50 UNI5931 screws.
Tighten the M8 UNI 5588 nut under the carter eyelet to avoid accidental
unfastening.
Fig. 6
SG-P ACCESSORY MOUNTING
Fasten the plate to the floor with the screws and insert the 3 load-bearing springs on the
spacers on the plate. Place the column on the springs so that the slots in the bottom plate
are aligned with the springs. Insert the M10 UNI 5931 screws and washers, provided with the
SG-P accessory, in the slots and tighten them while gradually pressing down upon the 3
load-bearing springs. During this phase the vertical axis can also be adjusted. Use as a
reference the spheric level and choose the rough angular position using the slots and the
reference marks on the bottom plate. The optimal working height for the load-bearing springs
(which corresponds to the distance between the fixed plate and the bottom plate) is
approximately 42 mm. Once it rests on a level surface and the maximum angular position
has been established, it is possible to perform a fine adjustment of the angular position by
working on the dowels and the lock nuts of the moulded plate (Fig. 7).
Fig. 7
T-nut in central guide
Side guides