Datalogic SG-LP SERIES Manual Download Page 4

Bring close the “d” bracket to the “b” ensemble completely and tighten the knurled knobs to firmly fix the 
system. 

 

Fix the “c” bracket to the “a” ensemble using one of the four knurled knobs, without tightening it completely 
in order to allow the mutual adjustment between “c” bracket and the laser pointer itself (Fig. 4).  
As shown in the previous figures it’s sufficient to place such obtained assembly on the light curtain front 
panel to have a first rough positioning. Bring close, then, the “d” bracket to the “b” ensemble tightening 
completely the corresponding knurled knobs (Fig. 5). 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig.5 

 

At this point screw last knob fixing together both the “c” and “d” brackets. Tighten the knob firmly keeping 
the laser pointer group close to the front panel of the curtain (Fig. 6). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 Fig.6 

Fig.7 

 

 
 

 
 
 

Laser pointer is positioned inside the detection field of the safety device and thus inhibits the functioning 
during the alignment phase. In case of safety devices for access control, this inconvenience can be avoided 
by positioning the laser pointer in a zone not affected by optic groups. The device functioning is thus not 
inhibited and the alignment results can be observed directly on the receiving unit’s signalling LEDs. 

 

ALIGNEMENT 

1)  Power on the laser pointer rotating pushing the dedicated switch. Orientate the emitting unit in order that 

the laser beam hits the receiving unit at the same height of the pointer. 

 

NOTE:  The holes of the fixing bracket or the orientable supports or the rotating brackets, available 
as accessories, can be used to orientate the unit, allowing angle adjustment along the vertical unit 
axis. If necessary the inclination of the floor stand can be changed by simply mounting washers 
under the base.  
 

2)  Repeat this procedure inserting the pointer in the lower part of the emitting unit; if necessary repeat this 

procedure unit the desired result is obtained. 

3)  Insert the laser pointer in the upper part of the receiving unit and orient this unit in order that the laser 

beam hits the emitting unit as indicated. 

4)  Repeat this procedure inserting the laser pointer in the lower part of the receiving unit. 
 

After this operation, fix the position of the light curtain remove the laser pointer from controlled area and 
switch on the safety device and verify the correct alignment.Finally, centre the laser pointer transversal 
position keeping it close to the front panel, fix defiantly (Fig.7). 

 

NOTE: The laser pointer, due to mechanical tolerance problems in the matching with the light 
curtain housing, provides an approximate indication and hence small corrections may be necessary 
in the unit alignment, following the ALIGNMENT PROCEDURE described in the safety light curtain 
instructions manual. 
 
FIXING 

 

To disengage the laser pointer is enough to totally unscrew the knobs shown in Fig. 10 and partially the 
remaining ones. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig.10

 

 
After the aforementioned operation firmly fix the TX and RX units. 
 
 
 
 
 
 

5

 

Completely tightened 

Completely 

tightened

 

Summary of Contents for SG-LP SERIES

Page 1: ...es Thanks to a specially designed CAM fixing equipment the laser pointer can be inserted into one of the two lateral grooves either from the top or from the side depending on which kind of fixing brackets have been used to mount the safety light curtain standard L or TOP BOTTOM Rotating ones One top and one lateral fixing brackets together with two tightening knobs allow to adjust SG LP laser poin...

Page 2: ...ate collection at an appropriate collection point Do not dispose of as household waste For more information contact the local authorities in charge of waste management Fig 1 INSTRUCTIONS INSTALLATION Install the emitting and receiving units of the SE SG series safety device in the defined positions refer to MECHANICAL MOUNTING chapter of the safety light curtain instructions manual The use of floo...

Page 3: ...ical position Fig 2 until you ve reached the right position Fig 4 SIDE MOUNTING Insert the b ensemble abutting on the curtain side corresponding to the lateral groove Keep the couple of cams in horizontal position Fig 3 and after they entered the groove rotate them of 90 Fig 4 3 Fig 3 Fig 4 Fig 2 a b c d ...

Page 4: ... height of the pointer NOTE The holes of the fixing bracket or the orientable supports or the rotating brackets available as accessories can be used to orientate the unit allowing angle adjustment along the vertical unit axis If necessary the inclination of the floor stand can be changed by simply mounting washers under the base 2 Repeat this procedure inserting the pointer in the lower part of th...

Reviews: