5
DIP SWITCHES CONFIGURATION
The device does not accept configuration changes during normal functioning.
A change is accepted only beginning from the successive powering of the device.
Particular attention has to be taken during the configuration dip-switch management and use.
Muting time-out “
” does not comply with the requirements of IEC 61496-1.
Therefore all possible risks must be considered and related precautions undertaken before
selecting the “
”option.
NOTE: For RX side the top and bottom dip-switches must be configured in the same manner.
The “ON” position is the default.
RX
TX
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
ON OFF
ON OFF
Dip switches n°1: Muting timeout
Dip switches n°2: Muting T/L
Dip switches n°3: Muting filter
Dip switches n°4: Override restart
Dip switches n°5: Override mode
Dip switches n°6: EDM enable
Dip switches n°7: coding selection
Dip switches n°8: coding selection
10 min
T
Disabled
Manual
Maintained
EDM on
See table
See table
L
Enabled
Automatic
Impulsive
EDM off
See table
See table
Dip switch n°1: coding selection
Dip switch n°2: coding selection
Dip switch n°3: not used
Dip switch n°4: not used
Dip switch n°5: not used
Dip switch n°6: not used
Dip switch n°7: not used
Dip switch n°8: not used
See table
See table
-
-
-
-
-
-
See table
See table
-
-
-
-
-
-
Dip-switches 7 Dip-switches 8
CODE
ON ON NO
CODE
OFF ON Code
1
ON OFF Code
2
OFF OFF Not
used
Dip-switch 1
Dip-switch 2
CODE
ON ON
NO
CODE
OFF ON Code
1
ON OFF
Code
2
OFF OFF
Not
used
DIAGNOSTICS FUNCTION
The operator can visualise the operating condition of the light curtains thanks to a one-digit display positioned on both the
RX and TX unit. SG-BODY also has four LEDs on the RX unit and two LEDs on the TX unit.
The figure below shows all signalling LEDs modes: OFF, ON.
LED OFF
LED ON
The operator can evaluate the main causes of the system stopping or failure using the 7-segment display and LEDs used
to visualise the functions. For the receiver: