DIP SWITCHES CONFIGURATION 

 

The device does not accept configuration changes during normal functioning. 
A change is accepted only beginning from the successive powering of the device. 
Particular attention has to be taken during the configuration dip-switch management and use.

 

 

 

Muting time-out “

” does not comply with the requirements of IEC 61496-1. 

Therefore all possible risks must be considered and related precautions undertaken before 
selecting the “

”option.

 

 

NOTE: For RX side the top and bottom dip-switches must be configured in the same manner. 
The “ON” position is the default. 
 

 

RX

 

TX

 

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

 

1

2

3

4

5

6

7

8

 

 

ON OFF 

 

ON OFF 

Dip switches n°1: Muting timeout 
Dip switches n°2: Muting T/L 
Dip switches n°3: Muting filter 
Dip switches n°4: Override restart 
Dip switches n°5: Override mode 
Dip switches n°6: EDM enable 
Dip switches n°7: coding selection 
Dip switches n°8: coding selection 

10 min 

Disabled 

Manual 

Maintained 

EDM on 

See table 
See table

 

 

Enabled 

Automatic 

Impulsive 

EDM off 

See table 
See table

 

Dip switch n°1: coding selection 
Dip switch n°2: coding selection 
Dip switch n°3: not used 
Dip switch n°4: not used 
Dip switch n°5: not used 
Dip switch n°6: not used 
Dip switch n°7: not used 
Dip switch n°8: not used 

See table 
See table 






See table 
See table

 






 
 

Dip-switches 7  Dip-switches 8 

CODE 

ON ON NO 

CODE 

OFF ON  Code 

ON OFF Code 

OFF OFF Not 

used 

 

Dip-switch 1 

Dip-switch 2 

CODE 

ON ON 

NO 

CODE 

OFF ON Code 

ON OFF 

Code 

OFF OFF 

Not 

used 

 

 

DIAGNOSTICS FUNCTION 

The operator can visualise the operating condition of the light curtains thanks to a one-digit display positioned on both the 
RX and TX unit. SG-BODY also has four LEDs on the RX unit and two LEDs on the TX unit.  
The figure below shows all signalling LEDs modes: OFF, ON. 
 

LED OFF

LED ON

 

 
The operator can evaluate the main causes of the system stopping or failure using the 7-segment display and LEDs used 
to visualise the functions. For the receiver: 

Summary of Contents for SG-BODY Series

Page 1: ...ly read the instructions for the correct functioning before powering the light curtain Precautions to be observed for the choice and installation of the device Make sure that the protection level assured by the SG BODY device Type2 Type4 is compatible with the real danger level of the machine to be controlled according to EN 13849 1 The outputs OSSD of the ESPE must be used as machine stopping dev...

Page 2: ... M12 12 Poles 1 brown 24Vdc 2 blue 0V 3 white RESET RESTART RESTART MODE 4 green OVERRIDE1 5 pink OSSD2 6 yellow EDM 7 black MUTING ENABLE 8 grey OSSD1 9 red OVERRIDE2 10 violet LAMP INPUT 11 grey pink OVERRIDE STATUS 12 red blue EARTH M12 5 Poles 1 brown 24 Vdc 2 white MUTING2 3 blue 0V 4 black MUTING1 5 grey NOT USED M12 5 Poles 1 brown 24 Vdc 2 white TEST 3 blue 0V 4 black EARTH 5 grey NOT USED...

Page 3: ...rtain alignment can be effected only after having completed the mechanical installation and the electrical connections The following procedure has to be followed NOTE SG BODY is equipped with a system which informs the user on the alignment obtained The alignment function can be activated when powering the device by keeping the normally open RESET RESTART contact closed for at least 0 5 seconds In...

Page 4: ...n LED on the RX unit is ON and beams are not interrupted then verify that the red LED turns ON if even one single beam is interrupted SAFE condition where an object has been detected This verification shall be made with the special cylindrical Test Piece having a size suitable to the resolution of the device used refer to paragraph 3 2 6 Controls after first installation E Switch OFF and ON the de...

Page 5: ...tion Dip switches n 8 coding selection 10 min T Disabled Manual Maintained EDM on See table See table L Enabled Automatic Impulsive EDM off See table See table Dip switch n 1 coding selection Dip switch n 2 coding selection Dip switch n 3 not used Dip switch n 4 not used Dip switch n 5 not used Dip switch n 6 not used Dip switch n 7 not used Dip switch n 8 not used See table See table See table Se...

Page 6: ...RE LOCKOUT recoverable EDM failure OSSDs OFF User must check EDM ENABLE line or dip switches EDM line external switching device and activate RESET line If ESPE does not reset user must contact Datalogic Automation Technical Support FAILURE LOCKOUT not recoverable Override connection failure OSSDs OFF User must check Override lines connection and turn OFF ON ESPE If the problem persists user must c...

Page 7: ...rsists user must contact Datalogic FAILURE LOCKOUT not recoverable Optical failure User must turn OFF ON ESPE If the problem persists user must contact Datalogic FAILURE LOCKOUT not recoverable Dip switch failure User must check dip switch configuration and turn OFF ON ESPE If the problem persists user must contact Datalogic ESPE OFF Power supply failure User must check power supply connection If ...

Page 8: ...oduct In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Datalogic S r l Via S Vitalino 13 40012 Calderara di Reno Italy Tel 39 051 3147011 Fax 39 051 3147205 www datalogic com Helpful links at www datalogic com Contact Us Terms and Conditions Support The warranty period for this product is 36 months See General Term...

Reviews: