This product is covered by one or more of the following patents.
DE202014007924.2U9; IT280386; EP1148346B1
(see www.patents.datalogic.com for patent list)
S65-PA-5-M13
Time-of-flight infrared background suppression sensor
INSTRUCTION MANUAL
SIGNALS
OUTPUT LED (yellow)
Yellow LEDs on, numbered as 1 and 2,
indicate activation of Q1 and Q2 outputs.
LEDs blink at the same time if measurement
is out of range or not available due to the
presence of environmental contamination.
POWER LED (green)
Green PWR LED on indicates that the device is switched on and
operating.
ACTIVE SETUP LED (green)
Green PNP/NPN LEDs on indicate that the device is in the selected
setup.
OUTPUT and POWER LEDS also indicate setup settings
(see “Setup”
chapter).
INSTALLATION
Sensor can be installed by means of the two through holes present on
the body, using screws (M4x35 or longer; max. tightening torque: 1Nm)
with washers and nuts.
If mating surface is not perfectly flat, a bracket is recommended.
Various adjustable brackets are available to help sensor positioning (see
accessories on the catalogue). Operating distance is measured from the
front surface of the sensor optics.
M12 connector can be aimed in two different ways, by working the
relevant retaining spring and turning the unit by 90° until it stops.
1)
Connect and fasten M12 connector when power is off.
2)
Connect power cable and/or I/O as indicated for every model.
3)
Fasten sensor to suitable support, making sure to first align the green
pointer at the centre of the target
4)
Sensor function will be available in a few seconds from switch-on.
5)
Allow warm-up time before starting normal operations
.
CONNECTIONS
S65-PA-5-M13-OO
S65-PA-5-M13-OOZ
NOTE: Wire colour refers to European standard.
S65-PA-5-M13-OO ADJUSTMENT
1. Set up the device as needed. Press SET1+SET2 > 3 sec until the 3 green
LEDs blink to enter the setup menu.
- Press SET 2 to navigate within the menu until output
→
→
- Press SET 1 to select setup.
- Press SET1 and SET2 > 6 sec to go back to
default setup. The new configuration will be saved
only when exit to the menu. The sensor system
will
automatically
reset
to
the
original
configuration if a new configuration is not detected
within 10 seconds.
2. Select hysteresis according to the application,
considering the environmental and the more critical
operating conditions.
3. Identify the target reading point using the green
visible pointer by pressing SET1 (or SET2) for 1 sec
< t < 3 sec (the pointer will remain active for 5 sec).
4. Make sure that the spot is inside the target surface to be acquired.
5.
Target Acquisition:
Press SET1 (or SET2) > 3sec to teach-in switching
point 1 or 2 until the yellow LED Q1 (or Q2) flashes.
NOTE:
a spot partialization could change detection performances.
READING AREA DIMENSIONS
Typical spot size
– squared section
SETUP
MODE menu
PNP/NPN
LIGHT/DARK
HYSTERESIS
Press SET1+SET2 for t > 3 sec, until all 3
green LEDs are flashing. Releasing the
buttons, the sensor enters MODE menu.
Press SET2 to navigate within the menu
(
→→
), press SET1 to select setup.
Q1 ON =
Setup
PNP
Q2 ON =
Setup
NPN
Q1 ON =
setup
LIGHT
Q2 ON =
setup
DARK
Q1 ON =
80 mm
hysteresis
Q2 ON =
50 mm
hysteresis
Q1+Q2 ON =
30 mm
hysteresis
for both outputs
(
NPN is not
available during I/O Link communication)
for both outputs
for both outputs
Restore Default Setup
Green Pointer
Teach-In
Key
Status LED negligible
LED OFF
Steady LED
LED ON and flashing
Press SET1 + SET2 for at least 6 sec; before
default setup there is a temporary darkening of
all LEDs, after which it is possible to release
the buttons.
Press SET1 (or SET2) for 1 sec. < t < 3 sec
to switch on the green pointer
Point the target. Press SET1 (or SET2) > 3 sec
until Q1 (or Q2) blinks, then release button to
acquire the target
TECHNICAL DATA
S65-PA-5-M13-OO
S65-PA-5-M13-OOZ
Supply voltage:
24 VDC ± 20%
Consumption:
< 2.2 W (excluding any loads)
Operating Distance:
0.3..5 m (90% white) / 0.3..4.5 m (18% grey) / 0.3..3.5 m (6 % black)
Minimum teach distance:
400 mm
Hysteresis:
30mm / 50mm / 80mm
Response time:
8.5 msec max.
Difference White 90%/Grey 18% and White 90%/Black 6%:
see chart
(value Typ, 1σ, T=25°C, ambient light <1Klux)
Thermal compensation error:
1.5 mm /°C (T
≠ 25°C)
Switching output:
Can be set up (PNP NPN / Light Dark) 100mA max.
Teach-in Input:
Active High (+24V) 1 sec < t < 3 sec
→
teach Q1 / 3 sec < t < 6 sec
→
teach Q2
Warming-up time:
20 min typ
Warnings:
Q1 (YELLOW) / Q2 (YELLOW) / ON PWR (GREEN) - PNP / NPN (GREEN)
Operating temperature:
-
15°… +55 °C (with device ON)
Storage temperature:
-
25 … +70 °C
Electrical strength:
500 VAC, 1 min between electronics and case
Insulation resistance:
> 20 M
, 500 VDC between electronics and case
Reading spot size:
typ 100x100 mm @ 5m
Pointer spot size (green):
typ 200x200 mm @ 5m
Max. deviation of pointer/reading spot axes origin:
+/- 40 mm
Emission and Wavelength:
LED / 850 nm
Ambient light rejection:
according to EN 60947-5-2,
Vibrations:
width 0.5 mm, frequency 10 … 55Hz, per axis (EN60068-2-6)
Shock resistance:
11 ms (30 G) 6 shocks for each axis (EN60068-2-27)
Humidity:
< 90% no condensation
Exposed material:
Body: ABS / Display: POLYESTER
Front side material:
PMMA
Mechanical protection:
IP67
Connections:
M12 - 5 poles
(Overall) Dimensions:
50 x 50 x 25 mm
Weight:
50 g.max.
I/O LINK Connection:
NO
(See parameter table on www.datalogic.com)
UL (requirements):
Class 2 power supply according to UL 508
Factory settings and default settings are (for both Q1 and Q2): PNP OUT, LIGHT mode, Switching distance 2 m, hysteresis = 80mm
OVERALL DIMENSIONS
SAFETY WARNINGS
All the regulations and rules concerning electric and mechanical
safety must be complied with during sensor operation.
The sensor must be protected against mechanical damage.
This product is only for indoor use.
MAINTENANCE
This device requires no special maintenance operations.
At any rate, take care to clean the optics surface with a compatible
detergent in order to avoid degraded performance.
Use protections for the plastic parts in case of dangerous
environment.
DIFFERENCE WHITE/GREY
– WHITE/BLACK
The sensors are NOT safety devices, and so MUST NOT be used in
the safety control of the machines where installed.
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com:
Contact Us,
Terms and Conditions,
Support
.
For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please
refer to the website at
© 2021 Datalogic S.p.A. and/or its affiliates
ALL RIGHTS RESERVED.
Without limiting the rights
under copyright, no part of this documentation may be reproduced, stored in or introduced into a retrieval
system, or transmitted in any form or by any means, or for any purpose, without the express written
permission of Datalogic S.p.A. and/or its affiliates. Datalogic and the Datalogic logo are registered
trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other trademarks
and brands are property of their respective owners. Datalogic reserves the right to make modifications
and improvements without prior notification.
821007522 Rev. C
1 sec < t < 3 sec
t > 6 sec
t > 3 sec