background image

 

 

This product is covered by one or more of the following patents. 

European Patent 851,211 B1; 1,111,690 B1; 1,148,346 B1; 1,209,487 B1. 

Italian Patent IT 1,321,772. 

 

S5N-Mx-

…-PP/NN SERIES 

INSTRUCTION MANUAL 

CONTROLS 

OUTPUT LED (S5N-

Mx…A00/B01/C01/C10/C21/D00/E01/F01/T01) 

The  yellow  LED  ON  indicates  that  the  N.O.  (normally  open)  output 
status is closed. 

STABILITY LED (S5N-

Mx…B01/C01/C21/E01/F01) 

The  green  LED  ON  indicates  that  the  received  signal  has  a  reserve 
greater than 30% compared to the output switching value. 

POWER ON LED (S5N-

Mx…G00) 

The green LED indicates that the sensor is operating. 

TRIMMER (S5N-

Mx…B01/C01/C21/E01/F01/T01) 

The  trimmer  can  be  used  to  adjust  sensitivity;  the  operating  distance 
increases turning the trimmer clockwise. 
 

WARNING: The trimmer rotation is limited to 270° by a mechanical stop. 
Do not apply excessive torque when adjusting (max 40 Nmm). 

INSTALLATION 

The sensor can be fixed by means of the M18x1 threaded body through 

 18 mm hole, using the two CH.24 nuts enclosed (22 Nm maximum 

tightening torque). 
Wide  range  of  accessories  available:  various  orientable  fixing  brackets 
ease the sensor positioning (please refer to the accessories listed in the 
general catalogue). 
The operating distance is measured from the front surface of the sensor 
lens. 

C  models

:  To  improve  the  detection,  the 

object has to be moved closer or further away 
from the front surface of the sensor lens. 
 
In  case  of  lateral  translation,  the  object  must 
move as indicated in the figure. 
 
 
 

CONNECTIONS 

The connections are compliant to the EN 60947-5-2 standard. 

 

 

+

 

 

10 … 30 Vdc 

N.C. OUTPUT 

BROWN 

WHITE 

BLACK 

BLUE 

N.O. OUTPUT 

0 V 

 

S5N-

Mx…G00 

+

 

 

10 … 30 Vdc 

TEST + 

BROWN 

WHITE 

BLACK 

BLUE 

TEST - 

0 V 

 

 

M12 CONNECTOR 

2

3

1

4

 

 

DIMENSIONS 

24

mm

RADIAL VERSION

FIBRE OPTIC VERSION

57
38

without trimmer

L
X

M O D E L S

with trimmer

67
43

AXIAL VERSION

69
38

without trimmer

L
X

M O D E L S

with trimmer

79
43

CABLE VERSION

24

4

4

M18x1

=

2.5

X

TRIMMER

10

M12

=

Ø4

OUTPUT LED

STABILITY LED

24

=

6.2

4

12

Ø

22

M18x1

Ø

2.2

TRIMMER

54.5

=

M12

10

STABILITY LED

OUTPUT LED

STABILITY LED

OUTPUT LED

14

12

LED STABILITY

LED DI USCITA

4

4

14.5

10

M18x1

L

L

X

M12

50

14.5

72.5

49

14.5

61

14.5

10

TRIMMER

 

TECHNICAL DATA 

 

S5N-MA AXIAL VERSION 

S5N-MR RADIAL VERSION

 

Power supply: 

10 … 30 Vdc (limit values) 

Ripple: 

2 Vpp max. 

Current consumption  
(output current excluded): 

35 mA max. 

Outputs: 

N.O. and N.C.; PNP or NPN

 

(short-circuit protection) 

Output current: 

100 mA max.  

Output saturation voltage: 

2 V max. 

Response time: 

0.5 ms (2 ms mod.F01/G00) 

Switching frequency: 

1 kHz (250 Hz mod.F01/G00) 

Indicators: 

OUTPUT LED (YELLOW) excluding mod.G00 

STABILITY LED (GREEN) (mod.B01/C01/C21/E01/F01) 

POWER ON LED (GREEN) (mod.G00) 

Setting: 

sensitivity trimmer (mod.B01/C01/C21/E01/F01/T01) 

Operating temperature: 

-

25 … 55 °C 

Storage temperature: 

-

25 … 70 °C 

Dielectric strength: 

500 Vac / 1 min. between electronic parts and housing 

Insulation resistance: 

>20 M

 / 500 Vdc, between electronic parts and housing 

Operating distance (typical values): 

A0

0: 0.1…4 M on R2 

B01: 0.1…3.5 m on R2 

C01: 0…60 cm 

C10: 0…10 CM 

C21: 0…35 cm 

D00: 0.5…10 cm 

F01/G00: 0…25 m 

E01: 30 mm with OF-42 / 100 mm with OF-43 

T01: 0.1…1 m on R2 

 

B01: 0.1…2 m on R2 

C01: 0…35 cm 

C10: 0…8 cm 
D00: 0…8 cm 

F01/G00: 0…20 m 

T01: 0

.1…1 m on R2 

Emission type: 

red (630 nm) (mod. D00/E01) / red (660 nm) (mod.B01/T01) 

infrared (880 nm) (mod. A00/C01/C10/C21/G00) 

Ambient light rejection: 

according to EN 60947-5-2 

Vibrations: 

0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6) 

Shock resistance: 

11 ms (30 G) 6 shock for every axis (EN60068-2-27) 

Housing material: 

Nickel-plated brass  

Lens material: 

PMMA 

Mechanical protection: 

IP67 Type 1 enclosure 

Connections: 

2 m cable 

 4 mm / M12 - 4 pole connector 

Weight: 

110 g. max. cable vers. / 60 g. max. connector vers.  

AtEx 2014/34/EU 

II 3D EX tc IIIC IP67 T85°C 

 

SETTING 

Setting of S5N-

Mx…A00 

Position the sensor and reflector on opposite sides.  
Find the points where the yellow LED (OUT) is switched ON and OFF in both vertical and horizontal positions, and fix the sensor in the center 
between these points. 

Setting of S5N-

Mx…B01/T01 

Position the sensor and reflector on opposite sides. 

Turn the sensitivity trimmer to the maximum position. 
Moving the sensor both vertically and horizontally, determine the power on 
and off points of the yellow LED (OUT) and then mount the sensor in the 
middle  of  the  points  defined.  Optimum  operation  is  obtained  when  the 
green LED (mod.B01) is ON and the yellow LED is OFF. 

B01  models

:  If  necessary  reduce  sensitivity  in  order  to  detect  very  small 

targets.  In  order  to  improve  alignment,  repeat  the  procedure  detailed 
above whilst progressively reducing the sensitivity. 

T01  model

:  Turn  the  sensitivity  trimmer  counterclockwise 

until the yellow LED turns ON 

(pos.A). 

Turn  slowly  the  trimmer  again  clockwise  until  the  yellow 
LED turns OFF 

(Operating condition, pos.B). 

Setting of S5N-

Mx…F01/G00/E01 with OF-43 (P/R fibre-optics) 

Position the sensors (fibre terminals) on opposite sides. 
Turn the sensitivity trimmer to maximum: moving the sensor both vertically 
and horizontally, determine the power on and off points of the yellow LED 
(OUT)  and  then  mount  the  sensor  in  the  middle  of  the  points  defined. 
Optimum operation is obtained when the green LED is ON and the yellow 
LED is OFF (the output function and the relative LEDs are inverted in the 
E01 model with the OF-43 fibre). 
If  necessary,  reduce  sensitivity  using  the  trimmer,  in  order  to  detect  very 
small targets. In order to improve alignment, repeat the procedure detailed 
above whilst progressively reducing the sensitivity. 

Setting of S5N-

Mx…C01/C21/E01 with OF-42 (proximity fibre) 

Turn the sensitivity trimmer to minimum: the green LED is ON, the yellow 
LED  is  OFF.  Position  the  target  to  detect  in  front  of  the  sensor  or  of  the 
fibre terminals. Turn the sensitivity trimmer clockwise until the yellow LED 
turns  ON 

(Target  detected  state,  pos.A). 

Remove  the  target,  the  yellow 

LED turns OFF. Turn the sensitivity trimmer clockwise until the yellow LED 
turns ON 

(Background detected state, pos.B). 

The trimmer reaches maximum if the background is not detected. 
Turn the trimmer to the intermediate position C, between the two positions 
A and B. The green LED must be ON. 

Setting of S5N-

Mx…C10/D00 

The  operating  distance  range  of  these  sensors  is  factory  preset:  please 
consider this feature when positioning. 

TEST FUNCTION (S5N-

Mx…G00) 

The TEST+ and TEST- inputs can be used to inhibit the emitter and verify 
that the system is correctly operating. 
The  receiver  output  should  switch  when  the  test  is  activated  while  the 
beam is uninterrupted. 
The inputs activating voltage range is 10 … 30 Vdc. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Datalogic S.r.l. 

Via S. Vitalino 13 - 40012 Calderara di Reno - Italy 
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com

 

 
Helpful links at www.datalogic.com: 

Contact Us,

 

Terms and Conditions,

 

Support

 
 
 

 

 

For information about the disposal of Waste Electrical and 
Electronic Equipment (WEEE), please refer to the website at 

www.datalogic.com

 

 
 
 
© 2007 - 2020 Datalogic S.p.A. and/or its affiliates 

 ALL RIGHTS RESERVED. 

 Without 

limiting  the  rights  under  copyright,  no  part  of  this  documentation  may  be  reproduced, 
stored in or introduced into a retrieval system, or transmitted in any form or by any means, 
or  for  any  purpose,  without  the  express  written  permission  of  Datalogic  S.p.A.  and/or  its 
affiliates.  Datalogic  and  the  Datalogic  logo  are  registered  trademarks  of  Datalogic  S.p.A.  in 
many  countries,  including  the  U.S.A.  and  the  E.U.  All  other  trademarks  and  brands  are 
property  of  their  respective  owners.  Datalogic  reserves  the  right  to  make  modifications 
and improvements without prior notification. 
 
 
 

 

821005714 Rev. E

 

 

MIN 

MAX 

 

Summary of Contents for S5N-M PP Series

Page 1: ... max connector vers AtEx 2014 34 EU II 3D EX tc IIIC IP67 T85 C SETTING Setting of S5N Mx A00 Position the sensor and reflector on opposite sides Find the points where the yellow LED OUT is switched ON and OFF in both vertical and horizontal positions and fix the sensor in the center between these points Setting of S5N Mx B01 T01 Position the sensor and reflector on opposite sides Turn the sensiti...

Page 2: ...60 g max vers a connettore AtEx 2014 34 EU II 3D EX tc IIIC IP67 T85 C REGOLAZIONI Regolazione S5N Mx A00 Posizionare il sensore e il riflettore su lati opposti Determinare i punti di accensione e spegnimento del LED giallo OUT in direzione verticale e orizzontale e fissare il sensore al centro tra i punti rilevati Regolazione S5N Mx B01 T01 Posizionare il sensore e il riflettore su lati opposti R...

Page 3: ...tEx 2014 34 EU II 3D EX tc IIIC IP67 T85 C EINSTELLUNG Ausrichtung S5N Mx A00 Montieren Sie den Sensor und den Reflektor gegenüberliegend Ermitteln Sie durch vertikale und horizontale Bewegung die Einschaltepunkte gelbe LED geht an und fixieren dann den Sensor zentrisch zwischen den Einschaltpunkunten Ausrichtung S5N Mx B01 T01 Montieren Sie den Sensor und den Reflektor gegenüberliegend Drehen Sie...

Page 4: ...EX tc IIIC IP67 T85 C REGLAGES Réglage S5N Mx A00 Placer le capteur et le réflecteur sur des côtés opposés Déterminer les points d allumage et d extinction de la LED jaune OUT dans la direction verticale et horizontale et fixer le capteur au centre entre les points relevés Réglage S5N Mx B01 T01 Placer le capteur et le réflecteur sur des côtés opposés Régler le trimmer de la sensibilité au maximum...

Page 5: ...10 0 8 cm D00 0 8 cm F01 G00 0 20 m T01 R2 上 0 1 1 m 发射类型 红色 630 nm D00 E01 型号 红色 660 nm B01 T01 型号 红外 880 nm A00 C01 C10 C21 G00 型号 环境光抑制 符合 EN 60947 5 2 振动 每个轴 0 5 mm 振幅 10 55 Hz 频率 EN60068 2 6 抗冲击性 每个轴 11 ms 30 G 6 次冲击 EN60068 2 27 外壳材料 镀镍黄铜 镜头材料 PMMA 机械保护 IP67 1 型外壳 连接 2 m 电缆Ø 4 mm M12 4 针连接器 重量 电缆版本最大 110 g 连接器版本最大 60 g AtEx 2014 34 EU II 3D EX tc IIIC IP67 T85 C 设置 S5N Mx A00 设置 将传感器和反射镜相对放置...

Page 6: ...s leur vente La Période de garantie durera trois ans à compter de la date d expédition par Datalogic sauf accord contraire écrit de Datalogic Datalogic ne sera pas responsable sous garantie si le Produit a été exposé ou soumis à l une des conditions ci dessous 1 maintenance réparation installation manutention emballage transport stockage fonctionnement ou utilisation inappropriée ou de toute façon...

Page 7: ...ahmen zu ergreifen FR Conformité CE La marque CE indique la conformité du produit aux exigences essentielles énoncées dans la directive européenne applicable Les directives et les normes applicables sont sujettes à des mises à jour de manière continue et le constructeur adopte rapidement ces mises à jour la déclaration de conformité UE est par conséquent un document vivant La déclaration de confor...

Reviews: