background image

QLM700 INSTALLATION MANUAL 

6  

 

ELECTRICAL CONNECTIONS 

 

CONNECTORS 

 

PWR-IN (Power In) 

M12 5P Male 

(A-coded) 

ID-NET (Out) 

M12 5P Female 

(A-coded) 

Pin Function 

Pin

 

Function 

1 Vdc 

1 Shield 

2 nc 

2 Vdc 

3 GND 

3 GND 

4 nc 

4 ID+ 

5 nc 

 

5 ID- 

 

TRG (Trigger) 

M12 4P Female 

(A-coded) 

I/O 

M12 8P Female 

(A-coded) 

Pin Function 

Pin

 

Function 

+V (I/O) 

+V (I/O) 

2 nc 

2 -V 

(I/O) 

-V (I/O) 

I2+ (input) 

4 I1+ 

(trigger) 

4 nc 

 

 

 

5 O1+ 

(output) 

 

  

 

6 O1- 

(output)   

  

 

7 O2+ 

(output)   

  

 

8 O2- 

(output)   

 

ETH1 (Profinet IO Port 1) 

M12 4P Female 

(D-coded) 

ETH2 (Profinet IO Port 2) 

M12 4P Female 

(D-coded) 

Pin Function 

Pin

 

Function 

1 TX+ 

1 TX+ 

2 RX+ 

2 RX+ 

3 TX- 

3 TX- 

4 RX- 

4 RX- 

 

 

 

 

 

 

AUX 

M12 5P Female 

(B-coded) 

 

Pin Function 

 

 

1 nc 

   

2 RXA 

   

3 GND 

   

4 TXA 

   

5 nc 

 

 

 

 

 

Reader 

25P D-Sub Female 

 

14 

25

13

 

Pin Function 

Pin 

Function 

Pin 

Function 

1, shell, 

Reader Chassis 

 

 

 

 

2 TXM 

10 

I2B 

18 

I1A 

3 RXM 

11 

O2+  19 

GND 

4 RTSM 

12 

O2-  20 

RXA 

5 CTSM 

13 

Vdc  21 

TXA 

6 I2A 

14 

nc 

22 

O1- 

7 GND 

15 

nc 

23 

ID+ 

8 O1+ 

16 

nc 

24 

ID- 

9 nc 

17 

nc 

25 

GND 

2

4

3

1

4

5

2

1

1

4

2

1

5

2

6

1

8

7

2

1

Summary of Contents for QLM700

Page 1: ...Port 2 Connector and LED 2 ID NET Connector and LED 7 Auxiliary Port Connector 3 Trigger Connector and LED 8 IP Address Selectors last octet 4 I O Connector and LED 9 Reading Device Connector 5 Profinet IO Port 1 Connector and LED 10 Mounting slots 6 821002140 1 9 7 3 4 8 10 2 5 6 ...

Page 2: ...uct page which describes specific Info Features Applications Models Accessories and Downloads including the Genius utility program which allows device configuration using a PC It provides RS232 and Ethernet interface configuration SERVICE Overview Warranty Extensions and Maintenance Agreements Sales Network Listing of Subsidiaries Repair Centers Partners Helpdesk Material Return Authorization LEGA...

Page 3: ...tor However there is not a second ID NET network connector for bus propagation and therefore the QLM700 cannot be used as an ID NET Slave The reading device is connected to the QLM700 through a standard 25 pin D sub connector Three rotary switches allow easy manual Network Addressing selection The following accessories make system cabling easy CBL 1487 connector or CS A2 02 G xx cable to build the...

Page 4: ...Connectors CBL 1487 PWR IN CONNECTOR M12 5P F A Coded 93A050045 FMC600 QLM I O CONNECTOR M12 8P M A Coded 93ACC0040 Cables CS A2 02 G 03 PWR IN Cable M12 5P FEMALE 90 4 WIRES 3M 95A251360 CS A2 02 G 10 PWR IN Cable M12 5P FEMALE 90 4 WIRES 10M 95A251260 CAB AUX03 SERIAL CABLE M12 3P MALE DB9 3M 93A051385 CBL 1480 01 ID NET Out In M12 5P MALE FEMALE 1M IDNET 93A050049 CBL 1480 02 ID NET Out In M12 ...

Page 5: ...me using the two M5x20 screws included in the package plus two specific commercial T nuts for example the Bosch Rexroth T nut 10 M5 cod 3 842 530 283 Mounting to other surfaces such as concrete walls or metallic panels requires appropriate user supplied parts screws screw anchors nuts etc The diagram below gives the overall dimensions of the QLM700 and shows the mounting through holes 39 1 55 9 5 ...

Page 6: ...t 6 O1 output 7 O2 output 8 O2 output ETH1 Profinet IO Port 1 M12 4P Female D coded ETH2 Profinet IO Port 2 M12 4P Female D coded Pin Function Pin Function 1 TX 1 TX 2 RX 2 RX 3 TX 3 TX 4 RX 4 RX AUX M12 5P Female B coded Pin Function 1 nc 2 RXA 3 GND 4 TXA 5 nc Reader 25P D Sub Female 1 14 25 13 Pin Function Pin Function Pin Function 1 shell Reader Chassis 2 TXM 10 I2B 18 I1A 3 RXM 11 O2 19 GND 4...

Page 7: ...Check the correct Power Supply polarity looking at the PWR IN LED before connecting other devices to the QLM700 The power supply must be between 10 and 30 Vdc only Voltage Drop and Max Distributed Current Calculations For correct ID NET network management the maximum number of readers which can propagate power through the QLs must be calculated so that max distributed current is not exceeded 4 0 A...

Page 8: ... for electrical specifications NOTE Pins 1 V I O and 3 V I O are derived from Vdc and GND and are useful for supplying the external trigger through the QLM700 power source however pins 1 and 3 of the TRG connector must not be used as power supply inputs to the QLM700 I O CONNECTOR I O is an 8 pin Female A Coded M12 connector It carries the signals for the additional I O Input 2 Secondary Trigger O...

Page 9: ...devices ID NET Network components One of the CS A2 02 G xx accessory cables can also be used see PWR IN paragraph 3 Connect the power supply cable to the QLM700 with no other devices connected and apply power checking that the polarity is correct the blue LEDs below both PWR IN and ID NET out M12 connectors must be turned on If instead the red LEDs are turned on the polarity is incorrect switch of...

Page 10: ...bedded rotary switches allowing easy manual selection of the last octet of the IP Address Valid selections for the last octet of the IP Address are shown in the table below Address selections outside of these values are not accepted 000 255 A valid selection for the last octet of the IP Address 777 Remote Assignment through the IPConfig application available on the reader s CD ROM 888 Static Assig...

Page 11: ...is activated ETH1 There are two LEDs below ETH1 which act as the Profinet IO Network Status indicator and the Port 1 Link Activity indicator They are driven according to the following tables ETH2 There are two LEDs below ETH2 which act as the Profinet IO Module Status indicator and the Port 2 Link Activity indicator They are driven according to the following table Network Status LED Off No power N...

Page 12: ...ects either to the next Profinet IO node or is left unconnected sealed by the protection cap In a star topology one of the two Profinet IO ports is connected to an Ethernet switch the other port remains unconnected The reading device connects to the 25 pin connector The ID NET interface allows a network of ID NET Slaves to be connected to the QLM700 s reading device which acts as the ID NET Master...

Page 13: ...0s Input Power Profinet IO Interface External Trigger for On Line Mode External Digital I O Devices Aux port for Reader Configuration ID NET Network ID NET Terminator NOTE The ID NET network must be terminated inserting an ID NET terminator into the last QL in the network ID NET on the QLM700 is internally terminated Profinet IO PLC Host 1 Configuration PC 2 3 4 6 Matrix 410 to next Profinet IO no...

Page 14: ... Datalogic Application Driver DAD Driver USER INTERFACE LED Indicators Power ID NET Trig I O ETH1 ETH2 Power On Polarity Error blue red Trigger Activity yellow IN2 yellow OUT1 red OUT2 green Network Status green red Link Activity green yellow Module Status green red Link Activity green yellow PHYSICAL FEATURES Mechanical Dimensions 200 x 81 x 40 mm 7 9 x 3 2 x 1 6 in Weight 500 g 17 64 oz ENVIRONM...

Page 15: ...roval of Datalogic could void the authority to use the equipment This device complies with PART 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference which may cause undesired operation This equipment has been tested and found to comply with the limits ...

Page 16: ...d below 2004 108 EC EMC Directive ______________________________________________ This Declaration is based upon compliance of the products to the following standards EN 55022 CLASS A ITE DECEMBER 2010 INFORMATION TECHNOLOGY EQUIPMENT RADIO DISTURBANCE CHARACTERISTICS LIMITS AND METHODS OF MEASUREMENTS EN 61000 6 2 SEPTEMBER 2005 ELECTROMAGNETIC COMPATIBILITY EMC PART 6 2 GENERIC STANDARDS IMMUNITY...

Reviews: