Gryphon Base Station
Advanced Configuration Guide
31
3. Enter service mode:
Command: $S,B00<CR>
4. Read the current value setting in the base station:
Command: $cMRTO<CR>
5. Change configuration ( Inter data packet timeout ):
Command: $CMRTOxx<CR>
Where xx is the value of the command:
• Input range from 00 to 05 (two digits)
• With the input setting above, the output setting value range from 5 minutes to 30 min-
utes, increase by 5.
6. Save the setting and exit service mode
Command: $Ar<CR>
The example below illustrates changing the value of Inter data packet timeout from 10 to 15
minutes: