Technical Specifications

24

   POWERSCAN™ PM/PBT9600

DECODE CAPABILITY

1D Bar Codes

GS1 Databar linear codes, UPC/EAN (A,E,13,8), including  P2/P5 
Addons, ISBN, ISSN, Code128, EAN128, ISBT128, Code39, Code39 Full 
ASCII, Code39 CIP, Code 32, Trioptic, Interleaved 2 of 5, IATA, Industrial 
2 of 5, Standard 2 of 5, matrix2 of 5, datalogic 2 of 5, follet 2 of 5, Cod

-

abar, Code11, MSI, Plessey, Code 93, Pharmacode, BC412

2D / Stacked Codes

DataMatrix (square, rettangular ), MaxiCode, QR Codes, (QR, Micro QR 
and Multiple QR codes), Aztec
Postal codes including: Australian Post, China Post, Japanese Post, KIX 
Post, Planet Code, Postnet, Royal Mail Code(RM45CC), IMB, Sweden 
Post,Portugal Post, LaPoste A/R 39
Stacked codes including EAN/JAN Composites, GS1 Databar Compos

-

ites, GS1 Databar Expanded Stacked; GS1 DataBar Stacked; GS1 
DataBar Stacked Omnidirectional, PDF417, MacroPDF, Micro PDF417, 
China sensible, DotCode

Other:

 OCR, Digimarc

REGULATORY

See Regulatory Addendum

Summary of Contents for PowerScan PM9600 Series

Page 1: ...PowerScan PM PBT9600 QUICK REFERENCE GUIDE Industrial Cordless Handheld Area Imager Bar Code Reader...

Page 2: ...t our website and would like to make comments or suggestions about this or other Datalogic publica tions please let us know via the Contact page Disclaimer Datalogic has taken reasonable measures to p...

Page 3: ...iable PIN Code 8 Power Off 8 Selecting the Interface Type 9 Interface Selection 9 Configuring the Interface 9 Country Mode 13 Programming 17 Using Programming Bar Codes 17 Configure Other Settings 17...

Page 4: ...Contents IV POWERSCAN PM PBT9600 Changing the Batteries 33 Battery Safety 34 Hex Numeric Keypad 36...

Page 5: ...purposes 1 2 End Users shall not distribute sublicense rent loan lease assign export re export resell ship or divert or cause to be exported re exported resold shipped or diverted directly or indirect...

Page 6: ...ware destroy all copies of the Software and all of its component parts and upon request provide an affidavit certifying your compliance with the foregoing The provisions of Sub sections 1 2 1 3 1 4 1...

Page 7: ...plication or disclosure of the Software by the U S Govern ment is subject to the restrictions for computer software developed at private expense as set forth in the U S Federal Acquisition Regula tion...

Page 8: ...12 1 Entire Agreement Amendment This document contains the entire agreement between the parties relating to use of the Datalogic Prod ucts and the licensing of the Software and supersedes all prior o...

Page 9: ...ntre SIAC Rules for the time being in force which rules are deemed to be incorporated by ref erence in this clause The seat of the arbitration shall be Singapore The number of arbitrators will be thre...

Page 10: ...EULA X POWERSCAN PM PBT9600...

Page 11: ...es display and 4k or 16k keyboards PBT9600 SRRB Bluetooth Standard Range standard and low density codes no display PBT9600 HPRB Bluetooth High Performance high standard and low density codes no displa...

Page 12: ...PowerScan PM PBT9600 can also function as a camera by capturing entire images or image portions of labels signa tures and other items Autoscanning An autoscan command causes the reader to scan continu...

Page 13: ...entry mode by default It means you can enter any numeric combination including F2 key By pressing the yellow arrow key bottom left corner you switch to the alphanumeric keyboard which enables the T9 t...

Page 14: ...es the field of view which should be positioned over the bar code Table 1 Aiming System The field of view indicated by the aiming system will be smaller when the reader is closer to the bar code and l...

Page 15: ...tery charger turn green and flash orange battery state of charge 50 green battery state of charge 50 during charge The battery is completely charged when the LED on the base station battery charger t...

Page 16: ...number of handhelds that can be simultane ously linked to a single base station Link Scanner as Serial Device to a Bluetooth Host Use this procedure to let the PowerScan PBT9600 commu nicate with a B...

Page 17: ...Bluetooth manager of the host device Link to Host in SPP Mode Link Scanner as HID device to a Bluetooth host Use this procedure to let the PowerScan PBT9600 send data to a Bluetooth host using the Bl...

Page 18: ...Scan PBT9600 can be set up to authenticate the remote system when connecting by entering a Bluetooth passkey or a PIN code If you want to set the security level and authentica tion options suitable fo...

Page 19: ...rface proceed to the corresponding chapter in the PowerScan 9600 Family PRG CONFIGURING THE INTERFACE Scan the appropriate programming bar code to select the interface type for your system NOTE Unlike...

Page 20: ...t RS232 STD RS 232 Wincor Nixdorf Select RS232 WN RS 232 for use with OPOS UPOS JavaPOS Select RS 232 OPOS USB Com to simulate RS 232 standard interface Select USB COM STDa a Download the correct USB...

Page 21: ...ce QUICK REFERENCE GUIDE 11 USB FOR TERMINALS USB HID POS Select USB HID POS USB Toshiba TEC Select USB Toshiba TEC USB FOR MAGELLAN SCANNERS USB for Magellans Select USB Magellan Scanners ETHERNET Se...

Page 22: ...rface 12 POWERSCAN PM PBT9600 Factory setting KEYBOARD USB Keyboard with standard key encoding Select USB Keyboard USB Keyboard with alternate key encoding Select USB Alternate Keyboard USB Composite...

Page 23: ...e supported by the keyboard Read the ENTER EXIT code before and after the Country Mode selection For a complete list of the available country modes refer to the Product Reference Guide Default Value C...

Page 24: ...Country Mode 14 POWERSCAN PM PBT9600 COUNTRY MODE CONTINUED Country Mode Denmark Country Mode France Country Mode French Canadian Country Mode Germany Country Mode Hungary Country Mode Italy...

Page 25: ...Country Mode QUICK REFERENCE GUIDE 15 COUNTRY MODE CONTINUED Country Mode Japanese 106 Key Country Mode Lithuanian Country Mode Norway Country Mode Poland Country Mode Portugal Country Mode Romania...

Page 26: ...Country Mode 16 POWERSCAN PM PBT9600 COUNTRY MODE CONTINUED Country Mode Spain Country Mode Sweden Country Mode Slovakia Country Mode Switzerland Country Mode United Kingdom...

Page 27: ...Scan an ENTER EXIT bar code once to enter Programming Mode scan the desired parameter settings scan the ENTER EXIT bar code again to accept your changes which exits Programming Mode and returns the re...

Page 28: ...with typical handheld reader operation Motion Sense is active and if the scanner detects motion the aiming pattern is turned on When the trigger is pulled illumination is turned on and the scanner att...

Page 29: ...e Flash On1 time Double Read Timeout1 prevents undesired multiple reads Stand Mode The scanner looks for changes within its field of view The Aiming Pattern is always on to show the optimum reading ar...

Page 30: ...es 20 POWERSCAN PM PBT9600 SCAN MODE CONTINUED Scan Mode Trigger Pulse Multiple Scan Mode Trigger Hold Multiple Scan Mode Flashing Scan Mode Always On Scan Mode Stand Mode Scan Mode Retained Trigger H...

Page 31: ...me ENTER EXIT PROGRAMMING MODE 2 Scan the Set Date bar code six digits for Year Month and Day YYYYMMDD from the Hex Numeric Key pad on page 36 Set Date 3 Scan Set Time six digits for Hours Minutes and...

Page 32: ...h 7 9 cm 3 1 Weight PM96XX w o display 425 gr 14 9 oz PM96XX w display max 455 gr 16 oz PBT96XX 415 gr 14 6 oz ELECTRICAL CHARACTERISTICS Battery Type Li ion battery pack Time of Recharge typical 25 C...

Page 33: ...0 to 70 C 40 to 158 F Humidity 0 to 95 non condensing Drop Resistance Withstands 50 drops from 2 4 m 8 ft 20 C Withstands 50 drops from 2 0 m 6 6 ft 20 C Ambient Light Immunity 100 000 Lux Water Dust...

Page 34: ...essey Code 93 Pharmacode BC412 2D Stacked Codes DataMatrix square rettangular MaxiCode QR Codes QR Micro QR and Multiple QR codes Aztec Postal codes including Australian Post China Post Japanese Post...

Page 35: ...3 5 MHz Programma ble Speed 19 2 kb s 500 kb s default 36 8 kb s 500 kb s default Typical Range in open air 100 m at 500 kb s 150 m at 19 2 kb s 180 m at 500 kb s 230 m at 36 8 kb s frequency hopping...

Page 36: ...cm 2 5 4 5 in 5 mils 3 8 41 cm 1 5 16 1 in 20 mils 4 157 cm 1 6 61 8 in 40 mils 5 5 242 9 cm 2 1 95 6 in EAN13 PM PBT9600 SR 13 mils 4 67 5 cm 1 5 26 5 in PBT PM9600 HP 13 mil 4 120 2 cm 1 5 40 2 in P...

Page 37: ...inter face the LED blinks until enumeration with the host is completed Reader beeps four times at highest frequency and volume upon power up Good Read Beep LED behavior for this indi cation is config...

Page 38: ...code type Ensure reader is programmed to read the type of bar code scanned Refer to the PRG for more information Bar code label is unreadable Check the label to ensure it is not defaced Try to scan a...

Page 39: ...whole unit consumable items 7 use of counterfeit or replacement parts that are neither manu factured nor approved by Datalogic for use in Datalogic manufactured Products 8 any damage or malfunctioning...

Page 40: ...com For quick access from the home page click on the search icon and type in the name of the product you re look ing for This allows you access to download Data Sheets Manuals Software Utilities and D...

Page 41: ...performance during scanning operations Follow the procedures described in this instruction sheet to keep your PowerScan device in good operating condi tion Common Cleaning Solutions The cleaners and...

Page 42: ...n dry cloth to remove any residue of the cleaning agent and ensure the unit is dry NOTE Disinfectants may be harsh on metal They are recommended for use only on enclosures CAUTION DO NOT spray or pour...

Page 43: ...ry door and extract the battery 3 Invert the sequence to insert the battery and lock the battery door WARNING Do not incinerate disassemble short terminals or expose to high temperature Risk of fire e...

Page 44: ...to the battery pack contacts In the event the battery pack leaks and the fluid gets into your eye do not rub the eye Rinse well with water and immediately seek medical care If left untreated the batt...

Page 45: ...scharging The typical manufacturer advertised useful life of LI batteries is one to three years depending on usage and number of charges etc after which they should be removed from ser vice especially...

Page 46: ...Hex Numeric Keypad 36 POWERSCAN PM PBT9600 HEX NUMERIC KEYPAD Use the bar codes that follow to enter numbers as you would select digits characters from a keypad HEX NUMERIC KEYPAD 0 1 2 3 4 5...

Page 47: ...Hex Numeric Keypad QUICK REFERENCE GUIDE 37 HEX NUMERIC KEYPAD CONTINUED 6 7 8 9 A B...

Page 48: ...Hex Numeric Keypad 38 POWERSCAN PM PBT9600 HEX NUMERIC KEYPAD CONTINUED C D E F...

Page 49: ...s mitted in any form or by any means or for any purpose without the express written permission of Datalogic S p A and or its affiliates Datalogic and the Datalogic logo are registered trademarks of Da...

Reviews: