background image

LED and Beeper Indications

Quick Reference Guide

25

Programming Mode

 - 

The following indications ONLY occur 

when the reader is in Programming Mode

.

INDICATION

DESCRIPTION

LED

BEEPER

Label Pro-
gramming 
Mode Entry

A valid program-
ming label has 
been scanned.

LED blinks 
continuously

Reader sounds 
four low fre-
quency beeps.

Label Pro-
gramming 
Mode Rejec-
tion of Label

A label has been 
rejected.

N/A

Reader sounds 
three times at 
lowest fre-
quency and 
current vol-
ume.

Label Pro-
gramming 
Mode Accep-
tance of Par-
tial Label

In cases where 
multiple labels 
must be scanned 
to program one 
feature, this indica-
tion acknowledges 
each portion as it is 
successfully 
scanned.

N/A

Reader sounds 
one short beep 
at highest fre-
quency and 
current vol-
ume.

Label Pro-
gramming 
Mode Accep-
tance of Pro-
gramming

Configuration 
option(s) have been 
successfully pro-
grammed via labels 
and the reader has 
exited Program-
ming Mode.

N/A

Reader sounds 
one high fre-
quency beep 
and 4 low fre-
quency beeps 
followed by 
reset beeps.

Label Pro-
gramming 
Mode Cancel 
Item Entry

Cancel label has 
been scanned.

N/A

Reader sounds 
two times at 
low frequency 
and current 
volume.

Summary of Contents for PowerScan PD953X

Page 1: ...PowerScan PD953X Industrial Corded Handheld Area Imager Bar Code Reader Quick Reference Guide...

Page 2: ...u can acquire printed versions by contacting your Datalogic repre sentative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media...

Page 3: ...8 Keyboard Interface 8 Country Mode 9 Caps Lock State 13 Numlock 14 Programming 15 Using Programming Bar Codes 15 Configure Other Settings 15 Resetting Product Defaults 15 Reading Parameters 16 Good...

Page 4: ...ii PowerScan PD953X...

Page 5: ...e shall mean acquire under license End User is not entitled to receipt or use of the source code of any licensed Software 1 4 Portions of the Datalogic Product are protected by the relevant and applic...

Page 6: ...any and all claims actions suits or pro ceedings as well as any and all losses liabilities damages costs and expenses including reasonable attorney s fees arising out of or accruing from or related to...

Page 7: ...ion of the laws of the country in which End User obtained the license to govern interpret and enforce all of End User s and Datalogic s respective rights duties and obligations arising from or relatin...

Page 8: ...therwise fails to appoint an arbitrator within 30 days of the date the other party appoints its the first appointed arbitrator will be the sole arbitrator provided that the arbi trator was validly and...

Page 9: ...sity codes DPM laser ink jet and dot peen Omni directional Operating To read a symbol or capture an image you simply aim the reader and pull the trigger Since the PowerScan PD953X is a powerful omni d...

Page 10: ...owerScan PD953X can also function as a camera by capturing entire images or image portions of labels signatures and other items Autoscanning An autoscan command causes the reader to scan continuously...

Page 11: ...the Front marking on the Cable Holder is facing out with the arrow pointing towards the front of the scanner 4 Insert the end of the cable into the socket of the Cable Holder 5 Push the Cover along th...

Page 12: ...tem will be smaller when the reader is closer to the bar code and larger when it is farther from the code Symbologies with smaller bars or elements mil size should be read closer to the unit Symbologi...

Page 13: ...ovided in this section For defaults and addi tional information associated with each interface proceed to the corresponding chapter in the PowerScan 9500 Family PRG Configuring the Interface Scan the...

Page 14: ...Interface Type 6 PowerScan PD953X RS 232 RS 232 standard interface RS 232 RS 232 Wincor Nixdorf RS232 WN RS 232 for use with OPOS UPOS JavaPOS RS 232 OPOS USB USB Com to simulate RS 232 standard inter...

Page 15: ...ued USB OEM can be used for OPOS UPOS JavaPOS USB OEM a Download the correct USB Com driver from www datalogic com USB Keyboard with standard key encoding USB KBD USB Keyboard with alternate key encod...

Page 16: ...character emulation for keyboard interfaces Keyboard Interface KEYBOARD WEDGE IBM AT or PS 2 PCs Standard Key Encoding KBD AT IBM AT or PS 2 PCs Standard Key Encoding without external keyboard KBD AT...

Page 17: ...ted by the keyboard This option is usable only with USB KBD and Keyboard Wedge interface without the Alternate Key mode COUNTRY MODE ENTER EXIT PROGRAMMING MODE Country Mode U S Country Mode Belgium C...

Page 18: ...an PD953X COUNTRY MODE continued Country Mode Czech Country Mode Denmark Country Mode France Country Mode French Canadian Country Mode Germany Country Mode Hungary Supports only the interfaces listed...

Page 19: ...Guide 11 COUNTRY MODE continued Country Mode Italy Country Mode Japanese 106 key Country Mode Lithuanian Country Mode Norway Country Mode Poland Country Mode Portugal Supports only the interfaces lis...

Page 20: ...e 12 PowerScan PD953X COUNTRY MODE continued Country Mode Romania Country Mode Spain Country Mode Sweden Country Mode Slovakia Country Mode Switzerland Supports only the interfaces listed in the Count...

Page 21: ...the format in which the reader sends character data This applies to keyboard wedge interfaces This does not apply when an alternate key encoding key board is selected ENTER EXIT PROGRAMMING MODE Caps...

Page 22: ...on specifies the setting of the Numbers Lock Numlock key while in keyboard wedge interface This only applies to alternate key encoding interfaces It does not apply to USB keyboard ENTER EXIT PROGRAMMI...

Page 23: ...ar code once to enter Programming Mode scan the desired parameter settings scan the ENTER EXIT bar code again to accept your changes which exits Program ming Mode and returns the reader to normal oper...

Page 24: ...si tion time and if no code is decoded will switch on again before the next acquisition The illuminator will remain on until the symbol is decoded As you read code symbols adjust the distance at which...

Page 25: ...ts undesired multiple reads while in this mode Trigger Hold Multiple When the trigger is pulled scan ning starts and the product scans until the trigger is released or maximum scan on time 1 has elaps...

Page 26: ...is detected Motionix motion sensing technology Scan the Enter Exit Programming bar code above then either of the barcodes below ENTER EXIT PROGRAMMING MODE Scan Mode Trigger Single Scan Mode Trigger...

Page 27: ...or transmitted to the host It is active only while the scanner is in Trigger Single mode If the scanner switches to a different Read Mode Pick Mode is automatically dis abled Multiple Label Reading Th...

Page 28: ...Description Physical Characteristics Dimensions Height 212 mm Length 110 mm Width 74 mm Weight without cable 330 gr without cable Electrical Characteristics Voltage Cur rent PD953X PD953X HP PD953X H...

Page 29: ...tion 2D 7 5 mils 1D 2 5 mil 2D 4 mil Depth of Field Typical a Symbology Standard Model High Performance Code 39 4 mils 6 17 cm 20 mils 4 55 cm 40 mils 4 85 cm 2 5 mils 2 6 cm 20 mils 3 70 cm 40 mils 3...

Page 30: ...Code RM45CC IMB stacked codes including EAN JAN Composites GS1 Databar Com posites GS1 Databar Expanded Stacked GS1 DataBar Stacked GS1 DataBar Stacked Omnidirectional MacroPDF Micro PDF417 PDF417 UPC...

Page 31: ...r beeps four times at highest fre quency and vol ume upon power up Good Read Beep A label has been successfully scanned by the reader LED behavior for this indica tion is configu rable via the feature...

Page 32: ...bel the soft ware shall turn the green spot on for the time specified by the configured value N A N A Image Cap ture When ready to capture image Blue light flashes 2 times when updating N A aExcept wh...

Page 33: ...abel Pro gramming Mode Accep tance of Par tial Label In cases where multiple labels must be scanned to program one feature this indica tion acknowledges each portion as it is successfully scanned N A...

Page 34: ...d Replaceable Unit isolation mode If the reader is reset the sequence will be repeated Press and release the trigger to hear the FRU indication code The following table describes the LED flashes beep...

Page 35: ...ce during scanning Use a soft dry cloth to clean the product If the product is very soiled clean it with a soft cloth moistened with a diluted non aggressive cleaning solution or diluted ethyl alcohol...

Page 36: ...ship and materials on the repaired assembly for a 90 day period starting from the date of shipment of the repaired product from Datalogic or until the expiration of the original warranty period whiche...

Page 37: ...or viii any consumable or equivalent e g cables power supply batteries keypads touch screen triggers etc No Assignment Customer may not assign or otherwise transfer its rights or obliga tions under t...

Page 38: ...support through its website Log on to www datalogic com and click on the SUPPORT link which gives you access to Downloads by selecting your product model from the dropdown list in the Search by Produc...

Page 39: ......