Default Configuration
Quick Reference Guide
15
ADVANCED FORMATTING PARAMETERS
format disabled
CAMERA CONTROL
exposure mode = automatic, based on entire image
POWER SAVE
Illumination power = ON
CODE SELECTION
issue identical codes = enable
enabled codes
Standard Code 39: no check digit control, variable code length;
EAN 8/EAN 13 / UPC A/UPC E without ADD ON: UPCE expansion disabled
Code 128: variable code length
PDF417
Datamatrix: rectangular, normal and inverted, variable code length
QR
disabled codes
Code 32, Interleaved 2/5, Codabar, Code 93, EAN 128, GS1 DataBar™, Micro
PDF417, Postal Codes, Maxicode, Composite Codes
,
Aztec.
READING PARAMETERS
trigger type normal, trigger level mode, flash on = 2 sec, flash off = 2 sec,
beeper tone = tone 1, beeper volume = high, beeper duration = 50 ms, user
defined beeper = tone 1, user defined beeper volume = high, user defined
beeper duration = 100 ms, code per scan = one code per scan, read per cycle
= one read per cycle, scan timeout = 5 sec, central code transmission = dis-
abled, order by code length = disabled, order by code symbology = disabled,
autoscan mode = disabled, autoscan aiming system = enabled, autoscan
hardware trigger = enabled, autoscan illumination system = disabled, stand
autoscan mode = normal, aiming system delay = disabled, good read spot =
short, safety time = 500 ms
IMAGE FORMATTING
Image Preset 1, 2, 3, 4
image format = JPEG, set JPEG quality factor = 50, brightness = 0%, contrast =
0%, zoom = 100%, color depth = 256 gray level.