background image

iv

PowerScan™ PBT9501-AR

and 12 shall survive termination of this Agreement.

4. Limited Warranty

Datalogic warrants that, under normal use and operation, the Software will con-
form substantially to the applicable Datalogic Product documentation for the
period specified in the same, provided that the Software is used with the Datalogic
Product. Datalogic's entire liability and End User's sole and exclusive remedy for
any breach of the foregoing limited warranty will be, at Datalogic's option, the pro-
vision of a downloadable patch or replacement software. 
Datalogic does not warrant (i) that Software will meet End User's requirements; (ii)
that Software will be uninterrupted or defect error free; (iii) any non conformity
derived from unauthorized use, and/or improper installation or repair not in com-
pliance with Datalogic Product documentation. End User agrees that the existence
of such non conformities or errors and Datalogic's inability to remedy such errors
shall not constitute a breach of this Agreement.
EXCEPT AS PROVIDED IN THIS AGREEMENT, THE DATALOGIC PRODUCT IS PRO-
VIDED "AS IS" AND DATALOGIC MAKES NO WARRANTIES OF ANY KIND, EXPRESS
OR IMPLIED, WRITTEN OR ORAL, WITH RESPECT TO THE DATALOGIC PRODUCT OR
SOFTWARE, AND SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MER-
CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

5. Limitation of Liability

EXCEPT AS PROVIDED IN THIS AGREEMENT, NEITHER DATALOGIC NOR ITS LICEN-
SORS SHALL BE LIABLE FOR ANY CLAIMS AGAINST END USER BY ANY OTHER
PARTY. IN NO EVENT SHALL DATALOGIC'S LIABILITY FOR DAMAGES, IF ANY,
WHETHER BASED UPON CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT
LIABILITY, STRICT LIABILITY, WARRANTY, OR ANY OTHER BASIS, EXCEED THE PRICE
OR FEE PAID BY END USER FOR THE DATALOGIC PRODUCT. UNDER NO CIRCUM-
STANCES SHALL DATALOGIC OR ITS LICENSORS BE LIABLE TO END USER OR ANY
THIRD PARTY FOR LOST PROFITS, LOST DATA, INTERRUPTION OF BUSINESS OR
SERVICE, OR FOR ANY OTHER SPECIAL, CONSEQUENTIAL, CONTINGENT, INDIRECT,
INCIDENTAL, PUNITIVE, EXEMPLARY, OR OTHER SIMILAR DAMAGES, EVEN IF DAT-
ALOGIC OR ITS LICENSORS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES. END USER  MUST BRING ANY ACTION UNDER THIS AGREEMENT
WITHIN 12 (TWELVE) MONTHS AFTER THE CAUSE OF ACTION ARISES.

6. Indemnification

To the maximum extent permitted by law, End User agrees to defend, indemnify
and hold harmless Datalogic, its affiliates and their respective directors, officers,
employees and agents from and against any and all claims, actions, suits or pro-
ceedings, as well as any and all losses, liabilities, damages, costs and expenses
(including reasonable attorney's fees) arising out of or accruing from or related to
Licensee's failure to comply with the terms of this Agreement, including but not
limited to (1) non compliance with any applicable laws or regulations with Data-
logic product documentation, (2) unauthorized use or disclosure of Software, and
(3) use of Software in combination with software, hardware, systems, or other
items not provided by Datalogic.

7. Support

End User may request support for Software from Datalogic at Datalogic's standard
support fees and under Datalogic's standard support terms and conditions in
effect at the time the support is requested.
8. Government Restricted Rights; International Use
8.1 Use, duplication, or disclosure of the Software by the U.S. Government is sub-
ject to the restrictions for computer software developed at private expense as set
forth in the U.S. Federal Acquisition Regulations at FAR 52.227-14(g), or 52.227-19
or in the Rights in Technical Data and Computer Software clause at DFARS
252.227-7013(c)(1)(ii), whichever is applicable.
8.2 If End User is using the Datalogic Product outside of the United States, End
User must comply with the applicable local laws of the country in which the Data-
logic Product is used and with U.S. export control laws,. Without prejudice of the
foregoing, the End User agrees to not export or re-export the Software, any part
thereof, or any process or service that is the direct product of the Software to any
country, person or entity subject to U.S. export restrictions. End User specifically
agrees not to export or re-export any of the Software: (i) to any country to which
the U.S. has embargoed or restricted the export of goods or services or to any
national of any such country, wherever located, who intends to transmit or trans-
port the Software  back to such country; (ii) to any person or entity who you know
or have reason to know will utilize the Software  in the design, development or pro-
duction of nuclear, chemical or biological weapons; or (iii) to any person or entity
who has been prohibited from participating in U.S. export transactions by any fed-
eral agency of the U.S. government. End User warrants and represents that nei-
ther the U.S. Commerce Department, Bureau of Export Administration nor any
other U.S. federal agency has suspended, revoked or denied its export privileges.

9. Third Party Software

The Datalogic Product may contain one or more items of third party software
which use is governed by separate third party license, unless otherwise stated.

Summary of Contents for PowerScan PBT9501-AR

Page 1: ...PowerScan PBT9501 AR Industrial Cordless Handheld Auto Range Area Imager Bar Code Reader Quick Reference Guide...

Page 2: ...sentative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media If you visit our website and would like to make comments or sugg...

Page 3: ...ults 6 Set Date and Time 7 Linking the Reader 8 Link Datalogic RF Devices to Base 8 Linking to a Bluetooth Adapter in Serial Port Profile Slave Mode 8 Linking to a Bluetooth Adapter in HID mode 9 Vari...

Page 4: ...ii PowerScan PBT9501 AR NOTES...

Page 5: ...shall mean acquire under license End User is not entitled to receipt or use of the source code of any licensed Software 1 4 Portions of the Datalogic Product are protected by the relevant and applica...

Page 6: ...t any and all claims actions suits or pro ceedings as well as any and all losses liabilities damages costs and expenses including reasonable attorney s fees arising out of or accruing from or related...

Page 7: ...ion of the laws of the country in which End User obtained the license to govern interpret and enforce all of End User s and Datalogic s respective rights duties and obligations arising from or relatin...

Page 8: ...otherwise fails to appoint an arbitrator within 30 days of the date the other party appoints its the first appointed arbitrator will be the sole arbitrator provided that the arbi trator was validly a...

Page 9: ...omni directional reader the orientation of the symbol is not important Decoding Thanks to powerful algorithms PowerScan PBT9501 AR reliably decodes all major 1D linear barcodes 2D stacked codes such...

Page 10: ...ould be aimed over the code center to get the best reading performance By completely pressing the trigger the illumination area appears and the code scan ning starts Aiming Pointer Scan the following...

Page 11: ...packs may get hot explode or ignite and cause serious injury if exposed to abu sive conditions Be sure to follow the safety warn ings that follow Do not place the battery pack in fire or heat Do not c...

Page 12: ...2 19 EU and subsequent modifications US and China regulatory and others laws and regulations about the environment CAUTION Always charge the battery at 32 104 F 0 40 C temperature range Use only the a...

Page 13: ...green The battery can also be charged in the spare battery slot BC91xx models only or using the Multi Battery Charger accessory Changing the Batteries 1 Push the button at the bottom of the handle as...

Page 14: ...to enter Programming Mode scan the desired parameter settings scan the ENTER EXIT bar code again to accept your changes which exits Program ming Mode and returns the reader to normal operation Config...

Page 15: ...and time ENTER EXIT PROGRAMMING MODE 2 Scan the Set Date barcode six digits for Year Month and Day YYMMDD from the Hex Numeric Keypad on page 29 Set Date 3 Scan Set Time six digits for Hours Minutes a...

Page 16: ...then scan the Unlink bar code before re linking to the new base Linking to a Bluetooth Adapter in Serial Port Profile Slave Mode 1 Install any drivers provided with the Bluetooth adapter 2 Scan the En...

Page 17: ...the application presents a window that includes a PIN Code which is to be input using the PowerScan PBT9501 AR Please read the bar code Vari able PIN Code and restart the sequence from step 2 above Wh...

Page 18: ...a Bluetooth Adapter in HID mode you may want to set the country for which your PC is localized In order to do that read one of the configuration command labels below HID COUNTRY MODE ENTER EXIT PROGR...

Page 19: ...Country Mode Quick Reference Guide 11 HID COUNTRY MODE continued Country Mode Czech Republic Country Mode Denmark Country Mode France Country Mode French Canadian Country Mode Germany Country Mode Hun...

Page 20: ...ID Country Mode 12 PowerScan PBT9501 AR HID COUNTRY MODE continued Country Mode Italy Country Mode Japanese 106 key Country Mode Lithuanian Country Mode Norway Country Mode Poland Country Mode Portuga...

Page 21: ...HID Country Mode Quick Reference Guide 13 HID COUNTRY MODE continued Country Mode Romania Country Mode Spain Country Mode Sweden Country Mode Slovakia Country Mode Switzerland...

Page 22: ...n PBT9501 AR HID Caps Lock State This option specifies the format in which the reader sends character data ENTER EXIT PROGRAMMING MODE Caps Lock State Caps Lock OFF Caps Lock State Caps Lock ON Caps L...

Page 23: ...Mode Read the configuration command label below for the HID Alt Mode feature Power Off Scan the bar code below to shut off power to the BT hand held until the next trigger pull PowerOff ENTER EXIT PRO...

Page 24: ...ing a label does not disable scanning Double Read Time out1 prevents undesired multiple reads in this mode Trigger Pulse Multiple When the trigger is pulled and released scanning is activated until pr...

Page 25: ...ode Quick Reference Guide 17 Operating Mode continued ENTER EXIT PROGRAMMING MODE Scan Mode Trigger Single Scan Mode Trigger Pulse Multiple Scan Mode Trigger Hold Multiple Scan Mode Flashing Scan Mode...

Page 26: ...igger Single mode If the scanner switches to a different Read Mode Pick Mode is automatically disabled Multiple Label Reading The reader offers a number of options for multiple label reading See the P...

Page 27: ...lower when battery is within daily typical operating condition Typical 10 hours with Host power in this case no supply adapter is needed a Operating auton omy continuous reading 40 000 reads typical 2...

Page 28: ...P2 P5 Addons UPC EAN Coupons ISBN Code128 EAN128 ISBT128 Code39 Code39 Full ASCII Code39 CIP Code 32 Codabar Inter leaved 2 of 5 IATA Industrial 2 of 5 Standard 2 of 5 Code11 MSI Plessey Code 93 Folle...

Page 29: ...ing Drop Specifications Scanner withstands up to 50 times 6 5 2 m drops to concrete Ambient Light Immu nity 100 000 Lux Contaminants Spray rain Dust particulates IP65 ESD Level 20 KV Beeper Speaker 80...

Page 30: ...de labels Table 1 Normal Operating Indicators INDICATION DESCRIPTION LED BEEPER Power up Beep The reader is in the process of powering up N A Reader beeps four times at highest fre quency and vol ume...

Page 31: ...3 beeps of descending fre quency ROM Failure There is an error in the reader s software pro gramming Flashes Reader sounds one error beep at highest volume Limited Scanning Label Read Indicates that a...

Page 32: ...labels must be scanned to program one feature this indica tion acknowledges each portion as it is successfully scanned N A Reader sounds one short beep at highest fre quency and cur rent volume Label...

Page 33: ...nce during scanning Use a soft dry cloth to clean the product If the product is very soiled clean it with a soft cloth moistened with a diluted non aggressive cleaning solution or diluted ethyl alcoho...

Page 34: ...p and materials on the repaired assembly for a 90 day period starting from the date of shipment of the repaired product from Datalogic or until the expiration of the original warranty period whichever...

Page 35: ...or viii any consumable or equivalent e g cables power supply batteries keypads touch screen triggers etc No Assignment Customer may not assign or otherwise transfer its rights or obliga tions under t...

Page 36: ...ough the Website Datalogic provides several services as well as technical support through its website Log on to www datalogic com For quick access from the home page click on the search icon and type...

Page 37: ...Hex Numeric Keypad Quick Reference Guide 29 Hex Numeric Keypad Use the barcodes that follow to enter numbers as you would select digits characters from a keypad 0 1 2 3 4 5...

Page 38: ...Hex Numeric Keypad 30 PowerScan PBT9501 AR Hex Numeric Keypad continued 6 7 8 9 A B...

Page 39: ...D E F For HID Variable Pin Code only If you make a mistake scan the CANCEL barcode below to abort and not save the entry string You can then restart Finish by scanning the Exit HID Variable PIN Code l...

Page 40: ...Hex Numeric Keypad 32 PowerScan PBT9501 AR NOTES...

Page 41: ...Hex Numeric Keypad Quick Reference Guide 33 NOTES...

Page 42: ...Hex Numeric Keypad 34 PowerScan PBT9501 AR NOTES...

Page 43: ......

Page 44: ...Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S and the E U Datalogic USA Inc 959 Terry Street Eugene OR 97402 U S A Telephone 541 68...

Reviews: