BT Address Stamping
Product Reference Guide
297
Source Radio Address Delimiter Character
This option specifies the delimiter character to be placed between the label data and radio
address when address stamping is enabled.
Follow these instructions to select the delimiter character:
1. Determine the desired character, then find its hexadecimal equivalent on the
on the inside back cover. A setting of 00 specifies no delimiter character.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
3. Scan the barcode: SET SOURCE RADIO ADDRESS DELIMITER CHARACTER.
4. Scan the appropriate two digits from the keypad in
, that represent
the hexidecimal characters which were determined in the steps above. You will hear a two-
beep indication after the last character.
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
for some examples of how to set this feature.
Table 36. Source Radio Address Delimiter Character Setting Examples
NOTE
This feature only applies if
Source Radio Address Transmission on
is enabled.
NOTE
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
No delimiter
character
, (comma)
- (dash)
/ (slash)
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SET SOURCE RADIO ADDRESS DELIMiTER CHARACTER
4
Scan Two Characters From
‘0’ and ‘0’
‘2’ and ‘C’
‘2’ and ‘D’
‘2’ AND ‘F’
5
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for POWERSCAN PBT7100 guide
Page 1: ...PowerScan PBT7100 Cordless Linear Imaging Barcode Reader Product Reference Guide...
Page 10: ...8 PowerScan PD7100 Corded NOTES...
Page 14: ...Introduction 4 PowerScan PBT7100 Cordless NOTES...
Page 56: ...General Features 46 PowerScan PBT7100 Cordless NOTES...
Page 82: ...RS 232 USB Com Interfaces 72 PowerScan PBT7100 Cordless NOTES...
Page 104: ...IBM 46XX Interface 94 PowerScan PBT7100 Cordless NOTES...
Page 281: ...Follett 2 of 5 Product Reference Guide 271 NOTES...
Page 282: ...Symbologies 272 PowerScan PBT7100 Cordless...
Page 328: ...318 PowerScan PBT7100 Cordless NOTES...
Page 332: ...322 PowerScan PBT7100 Cordless NOTES...
Page 334: ...324 PowerScan PBT7100 Cordless 6 7 8 9 A B C...
Page 335: ...Product Reference Guide 325 D E F...
Page 336: ...326 PowerScan PBT7100 Cordless NOTES...
Page 346: ...Product Reference Guide 336 IBM XT Table F 9 Scancode Set When Control Character is 00 or 01...
Page 347: ...Product Reference Guide 337 IBM XT cont Table F 10 Scancode Set When Control Character is 02...