Country Mode
10
POWERSCAN™ PM96XX
COUNTRY MODE (CONTINUED)
Country Mode = Denmark
Country Mode = France
Country Mode = French Canadian
Country Mode = Germany
Country Mode = Hungary
Country Mode = Italy
Page 1: ...PowerScan PM96XX QUICK REFERENCE GUIDE Industrial Cordless Handheld Area Imager Bar Code Reader...
Page 2: ...be downloaded from the Data logic website www datalogic com If you visit our website and would like to make comments or suggestions about this or other Datalogic publica tions please let us know via...
Page 3: ...6 Country Mode 9 Programming 13 Using Programming Bar Codes 13 Configure Other Settings 13 Resetting Product Defaults 13 Reading Parameters 14 Operating Modes 14 Scan Mode 14 Set Date and Time option...
Page 4: ...es 1 2 End Users shall not distribute sublicense rent loan lease assign export re export resell ship or divert or cause to be exported re exported resold shipped or diverted directly or indirectly the...
Page 5: ...ware destroy all copies of the Software and all of its component parts and upon request provide an affidavit certifying your compliance with the foregoing The provisions of Sub sections 1 2 1 3 1 4 1...
Page 6: ...ication or disclosure of the Software by the U S Govern ment is subject to the restrictions for computer software developed at private expense as set forth in the U S Federal Acquisition Regula tions...
Page 7: ...12 1 Entire Agreement Amendment This document contains the entire agreement between the parties relating to use of the Datalogic Prod ucts and the licensing of the Software and supersedes all prior o...
Page 8: ...e SIAC Rules for the time being in force which rules are deemed to be incorporated by ref erence in this clause The seat of the arbitration shall be Singapore The number of arbitrators will be three w...
Page 9: ...atrix symbols such as Data Matrix postal codes such as POSTNET PLANET The data stream acquired from decoding a symbol is rapidly sent to the host The reader is immediately available to read another sy...
Page 10: ...of items navigating menus etc For all related features and how to configure them refer to the Product Reference Guide The 16 key keyboard is active in numeric data entry mode by default It means you...
Page 11: ...es with larger elements mil size should be read farther from the unit Successful reading is signaled by an audible tone plus a good read green spot LED indicator and vibration Refer ence the PowerScan...
Page 12: ...s parts are shipped with a very low residual charge low state of charge Hence the needs that a new product must be fully recharged before starting to use it and that battery packs of the stocked produ...
Page 13: ...s then scan the Unlink bar code before re linking to the new base Unlink SELECTING THE INTERFACE TYPE Upon completing the physical connection between the reader base station and its host proceed direc...
Page 14: ...se interface selections by mistake or if additional scanner configuration is desired while in this state pull the trigger and hold for 5 seconds The scanner will change to a state that allows reading...
Page 15: ...EM USB OEM can be used for OPOS UPOS JavaPOS Select USB OEM USB FOR TERMINALS USB HID POS Select USB HID POS USB Toshiba TEC Select USB Toshiba TEC USB FOR MAGELLAN SCANNERS USB for Magellans Select U...
Page 16: ...USB Keyboard with standard key encoding Select USB Keyboard USB Keyboard with alternate key encoding Select USB Alternate Keyboard USB Composite Select USB Composite AT PS 2 with standard key encodin...
Page 17: ...terfaces select the specific country language supported by the keyboard Read the ENTER EXIT code before and after the Country Mode selection Default Value COUNTRY MODE ENTER EXIT PROGRAMMING MODE Coun...
Page 18: ...Country Mode 10 POWERSCAN PM96XX COUNTRY MODE CONTINUED Country Mode Denmark Country Mode France Country Mode French Canadian Country Mode Germany Country Mode Hungary Country Mode Italy...
Page 19: ...Country Mode QUICK REFERENCE GUIDE 11 COUNTRY MODE CONTINUED Country Mode Japanese 106 Key Country Mode Lithuanian Country Mode Norway Country Mode Poland Country Mode Portugal Country Mode Romania...
Page 20: ...Country Mode 12 POWERSCAN PM96XX COUNTRY MODE CONTINUED Country Mode Spain Country Mode Sweden Country Mode Slovakia Country Mode Switzerland Country Mode United Kingdom...
Page 21: ...can an ENTER EXIT bar code once to enter Programming Mode scan the desired parameter settings scan the ENTER EXIT bar code again to accept your changes which exits Programming Mode and returns the rea...
Page 22: ...typical handheld reader operation Motion Sense is active and if the scanner detects motion the aiming pattern is turned on When the trigger is pulled illumination is turned on and the scanner attempt...
Page 23: ...nts undesired multiple reads Stand Mode The scanner looks for changes within its field of view The Aiming Pattern is always on to show the optimum reading area If a predefined amount of move ment is d...
Page 24: ...odes 16 POWERSCAN PM96XX SCAN MODE CONTINUED Scan Mode Trigger Pulse Multiple Scan Mode Trigger Hold Multiple Scan Mode Flashing Scan Mode Always On Scan Mode Stand Mode Scan Mode Retained Trigger Hol...
Page 25: ...me ENTER EXIT PROGRAMMING MODE 2 Scan the Set Date bar code six digits for Year Month and Day YYYYMMDD from the Hex Numeric Key pad on page 31 Set Date 3 Scan Set Time six digits for Hours Minutes and...
Page 26: ...re Base Charger Supply Voltage BC9630 Host power 5VDC 5 or 10 30 VDC 5 External power 10 30 VDC 5 BC9631 Host power 5VDC 5 or 10 30 VDC 5 BC9680 External power 5VDC 5 or 10 30 VDC 5 with approved inte...
Page 27: ...0 to 70 C 40 to 158 F Humidity 0 to 95 non condensing Drop Resistance Withstands 50 drops from 2 4 m 8 ft 20 C Withstands 50 drops from 2 0 m 6 6 ft 20 C Ambient Light Immunity 100 000 Lux Contaminant...
Page 28: ...t Planet Code Postnet Royal Mail Code RM45CC IMB Sweden Post Portugal Post LaPoste A R 39 Stacked codes including EAN JAN Composites GS1 Databar Compos ites GS1 Databar Expanded Stacked GS1 DataBar St...
Page 29: ...mils 6 3 11 5 cm 2 5 4 5 in 5 mils 3 8 41 cm 1 5 16 1 in 20 mils 4 157 cm 1 6 61 8 in 40 mils 5 5 242 9 cm 2 1 95 6 in EAN13 PM96XX 13 mils 4 67 5 cm 1 5 26 5 in PM96XX HP 13 mil 4 120 2 cm 1 5 40 2 i...
Page 30: ...nter face the LED blinks until enumeration with the host is completed Reader beeps four times at highest frequency and volume upon power up Good Read Beep LED behavior for this indi cation is configur...
Page 31: ...code type Ensure reader is programmed to read the type of bar code scanned Refer to the PRG for more information Bar code label is unreadable Check the label to ensure it is not defaced Try to scan a...
Page 32: ...ole unit consumable items 7 use of counterfeit or replacement parts that are neither manu factured nor approved by Datalogic for use in Datalogic manufactured Products 8 any damage or malfunctioning c...
Page 33: ...com For quick access from the home page click on the search icon and type in the name of the product you re look ing for This allows you access to download Data Sheets Manuals Software Utilities and...
Page 34: ...ring scanning operations Follow the procedures described in this instruction sheet to keep your PowerScan device in good operating condi tion Common Cleaning Solutions The cleaners and disinfectants l...
Page 35: ...agent and ensure the unit is dry Windex Blue lsopropyl Alcohol Clorox Bleach Clorox Healthcare Bleach Germicidal Cleaner Sodium Hypochlorite Sodium Hydroxide Hydrogen Peroxide 3 ProSpray Wipes Disinf...
Page 36: ...door and extract the battery 3 Invert the sequence to insert the battery and lock the battery door WARNING Do not incinerate disassemble short terminals or expose to high temperature Risk of fire exp...
Page 37: ...s to the battery pack contacts In the event the battery pack leaks and the fluid gets into your eye do not rub the eye Rinse well with water and immediately seek medical care If left untreated the bat...
Page 38: ...arging The typical manufacturer advertised useful life of LI batteries is one to three years depending on usage and number of charges etc after which they should be removed from ser vice especially in...
Page 39: ...Hex Numeric Keypad QUICK REFERENCE GUIDE 31 HEX NUMERIC KEYPAD Use the bar codes that follow to enter numbers as you would select digits characters from a keypad HEX NUMERIC KEYPAD 0 1 2 3 4 5...
Page 40: ...Hex Numeric Keypad 32 POWERSCAN PM96XX HEX NUMERIC KEYPAD CONTINUED 6 7 8 9 A B...
Page 41: ...Hex Numeric Keypad QUICK REFERENCE GUIDE 33 HEX NUMERIC KEYPAD CONTINUED C D E F...
Page 42: ......
Page 43: ......
Page 44: ...mitted in any form or by any means or for any purpose without the express written permission of Datalogic S p A and or its affiliates Datalogic and the Datalogic logo are registered trademarks of Data...