Electrical Accessories
Installation Guide
7
Electrical Accessories
Installation of the PMD may require accessory electronic equipment for
proper and safe operation. Some of this equipment may not be available
through Datalogic, but could be available through your dealer, forklift parts
provider, or other suppliers. See Appendix A, “Accessories and Peripherals” on
page 23.
DC/DC Converter.
Voltage step down device used to power the PDA from
+24, +36 and +48 volt battery systems.
DC Conditioner/UPS.
Used to provide backup DC power during sags or
interruptions in battery voltage due to peak loads or disconnect.
Delay Timer.
Provides automatic shut-off of power to a PDA or other equip-
ment, to reduce battery drain.
Noise Spike/RF Filter.
Used to suppress high voltage and RF voltage
spikes on the power system.
Electrical Accessory Matrix
Table 1 summarizes the accessory recommendations and options available
depending on the forklift voltage application. This matrix should be used only
as a reference and may not include accessories for all applications.
Table 1. Electrical Accessories
*Ensure that the device being installed is properly rated for use on your mobile platform.
Accessory
Forklift System Voltage
12 volt
24 volt
36 volt
48 volt
DC/DC Converter
Not Required
Required
Required
Required
DC Conditioner/UPS
Optional*
Not Required
Not Required
Not Required
Delay Timer
Optional*
Optional*
N/A
N/A
Noise Spike/RF Filter
Recommended
Recommended
Recommended
Recommended
5-Amp Dock In-Line Fuse
Required
Required
Required
Required
Summary of Contents for Pegaso
Page 1: ...Pegaso Powered Mobile Dock Installation Guide ...
Page 16: ...Electrical Considerations 10 Pegaso Powered Mobile Dock NOTES ...
Page 26: ...Power and Peripheral Device Connections 20 Pegaso Powered Mobile Dock NOTES ...
Page 28: ...Troubleshooting 22 Pegaso Powered Mobile Dock NOTES ...
Page 32: ...Accessories and Peripherals 26 Pegaso Powered Mobile Dock NOTES ...
Page 35: ......