![Datalogic P2x-Series Product Reference Manual Download Page 64](http://html1.mh-extra.com/html/datalogic/p2x-series/p2x-series_product-reference-manual_3742503064.webp)
56
P2X-SERIES™
CHAPTER 7
MAINTENANCE
CLEANING
Clean the lens cover periodically for continued correct operation of the camera.
Dust, dirt, etc. on the lens cover may alter the reading performance.
Repeat the operation frequently in particularly dirty environments.
Use soft material and alcohol to clean the lens cover and avoid any abrasive substances.
TROUBLESHOOTING
General Guidelines
•
When wiring the device, pay careful attention to the signal name (acronym) on the
CBX500/800 spring clamp connectors. If you are connecting directly to the P2x-
Series™ M12 17-pin connector pay attention to the pin number of the signals.
•
If you need information about a certain camera parameter you can refer to the
Impact Reference Guide.
•
If you’re unable to fix the problem and you’re going to contact your local Datalogic
office or Datalogic Partner, we suggest providing (if possible): software version,
Serial Number, and Order Number of your camera. You can get some of this infor-
mation while VPM is connected to the camera. The software version is shown in
the About dialog, and the Serial Number can be obtained from the Device Connec-
tion Dialog.
TROUBLESHOOTING GUIDE
Problem
Suggestion
Power ON:
the “POWER” LED is not
lit.
•
Is power connected?
•
If using a power adapter (like PG6000), is it connected to
wall outlet?
•
If using rail power, does rail have power?
•
If using CBX, does it have power (check switch and LED)?
•
Check if you are referring to the M16 19-pin connector or
to the CBX spring clamp connectors.
•
Measure Voltage either at pin
A
and pin
L
(for 19-pin con-
nector) or at spring clamp
Vdc
and
GND
(for CBX).
Summary of Contents for P2x-Series
Page 1: ...P2x Series P2x Series P2x Series P2X Series PRODUCT REFERENCE GUIDE Industrial Smart Camera...
Page 13: ...GENERAL VIEW PRODUCT REFERENCE GUIDE 5...
Page 32: ...INSTALLATION 24 P2X SERIES Figure 4 STD Fix Bracket Overall Dimensions SLOTS SLO TS...
Page 34: ...INSTALLATION 26 P2X SERIES Figure 6 Overall Dimensions with Connector at 90...
Page 36: ...INSTALLATION 28 P2X SERIES Figure 8 Pivot Fix Bracket for 36 LEDs Illuminator small BK 32 010...
Page 68: ...TECHNICAL FEATURES 60 P2X SERIES Optical sensor response...