ELECTRICAL CONNECTIONS
30
P-SERIES™
Outputs
Three general purpose
non opto-isolated
but short circuit protected outputs are avail
-
able on the M12 17-pin connector.
The pinout is the following:
The electrical features of the three outputs are the following:
Reverse-Polarity and Short-Circuit Protected
V
OUT
(I
LOAD
= 0 mA) max = 30 Vdc
V
OUT
(I
LOAD
= 100 mA) max = 3 Vdc
I
LOAD
max = 100 mA
The output signals are fully programmable using the Discrete Output tool in VPM.
Figure 20 - PNP Output Connection
Figure 21 - NPN Output Connection
Datalogic SIL Spot red flood strobe
To use the Datalogic SIL strobe with the P-Series™ camera and a CBX500/800, make the
following connections to the CBX box. Output 3 must be configured as shown (VPM –
Pin
Name
Function
9
O1
Configurable digital output 1
8
02
Configurable digital output 2
16
O3
Configurable digital output 3
2
GND
Output reference signal
CAUTION
For NPN output connections, the external interface voltage (Vext) must not
exceed the P-Series™ power supply source voltage (Vdc) otherwise cor
-
rect output functioning cannot be guaranteed.
P-Series
User Interface
2
9/8/16
P-Series
User Interface
2
9/8/16
Vext