background image

CFast Card

MX-U Series Hardware Guide

Datalogic Automation, Inc.

2-8

CFast Card

A CFast slot is located in the Processor front. A CFast card can be used as removable media for transferring data, perform-

ing upgrades, or for extended storage.

This CFast slot is connected to the chip set internally via SATA 1 with SATA III design (SATA 6 Gbit/s).

WARNING: Power must be disconnected before inserting or removing the CFast card.

To exchange the CFast card

1. Press down on the slot cover’s top clip to open the slot.
2. Press the ejector at the bottom of the slot with a pointed object, such as a pen.
3. Pull the card straight out.
4. Insert the new card straight into the slot.
5. Close the slot cover.

CFast Slot cover

Processor Front View

Ejector (behind cover)

Summary of Contents for MX-U100

Page 1: ...MX U Series Hardware Guide for Processor and Cameras Publication Number 821003223 Rev C...

Page 2: ...n Inc Patent See www patents datalogic com for patent list This product is covered by one or more of the following patents Utility patents US6 512 218 B1 US6 616 039 B1 US6 808 114 B1 US6 997 385 B2 U...

Page 3: ...Inc product contact your distributor or Datalogic Automation Inc Please have the following information available before you call The version number of Impact Software Suite you are running To find it...

Page 4: ......

Page 5: ...oncepts 2 6 USB Hardware Key 2 7 CFast Card 2 8 Battery 2 9 Chapter 3 MX U Series Cameras Introduction 3 1 Safety Precautions 3 1 U1xx Camera Dimensions 3 3 Mounting the Camera 3 3 Connecting the Came...

Page 6: ...nts MX U Series Hardware Guide TOC 2 Datalogic Automation Inc Ethernet 5 1 Input Output 5 1 Power Supply 5 1 Serial Port 5 2 Monitor Panel 5 2 Display Port 5 2 USB Processor to Camera 5 2 Camera Cable...

Page 7: ...to the carrier immediately Save all packing materials so you can repack the shipment in case you need to move or ship it Temperature precautions If your system arrives in very cold or hot weather all...

Page 8: ...nes annulera la garantie du produit 1 Read all of the following instructions before setting up your system Save this document for later use 2 Follow all warnings and instructions in this manual and in...

Page 9: ...Outputs 16 opto isolated current sinking Output Voltage 35 VDC max Output Current 100 mA max per output Output saturation voltage 1V Dimensions 5 12 w x 10 63 h x 10 03 d in 130 w x 270 h x 255 d mm T...

Page 10: ...ng and optional power supply See Mounting the Camera on page 3 3 NOTE Do not leave the camera imager uncovered When you remove the lens cap you must replace it with a lens 6 Connect the camera to a Pr...

Page 11: ...your network 14 Start the Impact Software program Vision Program Manager and click on the Settings tab Check your camera and lighting setup calibrate the camera configure your inspection parameters th...

Page 12: ...rd Mouse 2 ETH2 Ethernet 2 See Status Lights on page 1 9 3 ETH1 Ethernet 1 See Status Lights on page 1 9 4 RS232 Serial Port COM 1 See Serial Port on page 5 2 5 Display Port connection 6 Monitor Panel...

Page 13: ...ton Press and release to turn on the unit If the unit is on press and release to shut down the OS and switch off the unit Press and hold to switch off without OS shut down Warning Data could be lost C...

Page 14: ...Rear View MX U Series Hardware Guide Datalogic Automation Inc 1 8 Rear View This illustration shows the Processor s rear panel...

Page 15: ...l Name When lit indicates 1 Power Power is On 2 HDD Solid state hard drive or Cfast access is active 3 Link On An active Smart Display Link connection is estab lished Blinking Connection is interrupte...

Page 16: ...s is highly recommended Verify that all cable connections are correct and tight Secure the cables to prevent accidents or damage to the device connectors When you move the system be careful that the m...

Page 17: ...tomation Inc C H A P T E R 2 Basic Hardware Components Processor Views and Dimensions This section shows specifications for the Processor including various views and dimensions Top View UNITS mm Rear...

Page 18: ...Processor Views and Dimensions MX U Series Hardware Guide Datalogic Automation Inc 2 2 Side View Air Inlet Filter Inside UNITS mm...

Page 19: ...Series Processors An optional power supply is available for MX U Series Processors If you provide your own it must supply 24VDC at 5 5 A nominal with a safe operating ambient temperature range of 0 t...

Page 20: ...location using the drilling template dimensions 2 Drill four surface mounting holes in the mounting surface Use suitable anchors if necessary 3 Insert four M5 mounting screws in the mounting holes an...

Page 21: ...nal pin 2 on the 24V power input must be connected to the power supply s grounded chas sis enclosure This connection is needed to insure electromagnetic compliance and proper operation See Grounding C...

Page 22: ...against electric shock The functional ground on the processor has two connections Supply voltage GND terminal Grounding connection on the processor back panel To guarantee a good functional ground Co...

Page 23: ...ordered and shipped separately from the processor It must be present in the USB port labeled USB5 on the processor front before the processor is pow ered on The USB Hardware key 18 x 12 x 5 mm A USB H...

Page 24: ...e chip set internally via SATA 1 with SATA III design SATA 6 Gbit s WARNING Power must be disconnected before inserting or removing the CFast card To exchange the CFast card 1 Press down on the slot c...

Page 25: ...and should be replaced at least every four years WARNING Power must be disconnected before replacing the battery To replace the battery 1 Disconnect the power supply to the processor 2 Touch the hous...

Page 26: ...Battery MX U Series Hardware Guide Datalogic Automation Inc 2 10...

Page 27: ...l scan etc are configured using Impact software and are maintained in the MX U Series processors memory so there are no physical switches on the cameras All camera settings must be configured using th...

Page 28: ...and pedestrian traffic Check the intended installation area to be sure there is enough room for the camera and any lighting that may be needed Avoid areas with excessive heat vibration and environmen...

Page 29: ...era mounting block To mount a U1xx camera 1 With the mounting block held tightly against the camera body insert two mounting bolts through the block Bottom View UNITS inch mm Power Trigger Connection...

Page 30: ...tely sized fasteners in the pre threaded holes in the bottom of the mounting block to secure it to a rigid surface for proper stability and heat transfer See U1xx Camera Dimensions on page 3 3 U1xx Mo...

Page 31: ...ame Signal Notes Optional Camera Power DO NOT USE Do NOT apply power to this terminal Power is supplied by the USB connection See Top Panel Connections on page 1 6 Optional Camera Power Ground DO NOT...

Page 32: ...Automation Inc 3 6 U1xx Circuit Diagrams U1xx Trigger In Circuit WARNING Never wire U1xx Camera Strobe Outputs in parallel with other U1xx Camera Strobe Outputs This will dam age the cameras U1xx Stro...

Page 33: ...MX U Series Hardware Guide U1xx Camera Connection 3 7 Datalogic Automation Inc U1xx Terminal Connections...

Page 34: ...the connector on the rear of the camera push gently until the cable connector seats securely then tighten the connector collar To disconnect it loosen the collar com pletely then grasp the connector...

Page 35: ...lternate U1xx Trigger Input circuit sourcing Set Software Trigger Event to Falling Edge U1xx Trigger Input circuit sinking Set Software Trigger Event to Rising Edge U1xx Strobe Output circuit sourcing...

Page 36: ...Alternate MX U Series Hardware Guide Datalogic Automation Inc 3 10 U1xx Terminal Connections Alternate U1xx Strobe Output circuit sinking Set Software Strobe Trigger Output to Falling Edge U1xx Termi...

Page 37: ...MX U Series Hardware Guide U1xx Camera Connection Alternate 3 11 Datalogic Automation Inc U1xx Unterminated Cable Connections Alternate U1xx Unterminated Cable Connections...

Page 38: ...e cameras with a MX U Series processor Refer to the Camera Setup Tab section of the Impact Software Reference Guide Calibration insures that measurements shown in Impact software tools accurately indi...

Page 39: ...to a maximum of 300 Megapixels per sec ond For four cameras each camera can use up to a maximum of 150 Megapixels per second This means that both the camera resolution and the number of connected cam...

Page 40: ...ick up Device Progressive Scan CCD 659 H x 494 V pixels Sensor Size 1 4 3 69 mm x 2 77 mm Capture Rate 120 full resolution frames per second fps higher with partial scan see Capture Rate on page 3 13...

Page 41: ...933030 959933031 Pick up Device Global Shutter CMOS 640 H x 480 V pixels Sensor Size 1 4 3 8 mm diag 3 07mm H 2 3mm V Capture Rate 750 full resolution fps higher with partial scan see Capture Rate on...

Page 42: ...9933002 Pick up Device Progressive Scan CCD 659 H x 494 V pixels Sensor Size 1 3 4 88mm H 3 66mm V Capture Rate 90 full resolution fps higher with partial scan see Capture Rate on page 3 13 Pixel Size...

Page 43: ...933006 Pick up Device Progressive Scan CCD 1296 H x 966 V pixels Sensor Size 1 3 4 86mm H 3 62mm V Capture Rate 30 full resolution fps higher with partial scan see Capture Rate on page 3 13 Pixel Size...

Page 44: ...ions Part Number 959933032 959933033 Pick up Device Global Shutter CMOS 1280 H x 1024 V pixels Sensor Size 1 2 8 mm diag 6 14mm H 4 92mm V Capture Rate 200 full resolution fps higher with partial scan...

Page 45: ...933008 Pick up Device Progressive Scan CCD 1628 H x 1236 V pixels Sensor Size 1 1 8 7 16mm H 5 44mm V Capture Rate 20 full resolution fps higher with partial scan see Capture Rate on page 3 13 Pixel S...

Page 46: ...er 959933034 959933035 Pick up Device Global Shutter CMOS 1920 H x 1200 V pixels Sensor Size 2 3 9 5mm H 6 08mm V Capture Rate 150 full resolution fps higher with partial scan see Capture Rate on page...

Page 47: ...3011 959933012 Pick up Device CMOS 2048 H x 1088 V pixels Sensor Size 2 3 11 26mm H 5 98mm V Capture Rate 165 full resolution fps higher with partial scan see Capture Rate on page 3 13 Pixel Size 5 5...

Page 48: ...9933014 Pick up Device CMOS 2048 H x 2048 V pixels Sensor Size 1 14 8 mm diag 11 26 mm H x 11 26 mm V Capture Rate 90 full resolution fps higher with partial scan see Capture Rate on page 3 13 Pixel S...

Page 49: ...mber 959933009 959933010 Pick up Device Progressive Scan CMOS Rolling Shutter 2592 H x 1944 V pixels Sensor Size 1 2 5 5 70 mm H x 4 28mm V Capture Rate 14 full resolution fps see Capture Rate on page...

Page 50: ...e specifications for these cameras consult the manufac turer s documentation You must purchase a license from Datalogic to connect a third party camera to the MX U Series pro cessor JAI Camera This ca...

Page 51: ...ice driver 1 Use a USB cable to connect the camera to one of the USB camera ports on the processor 2 On the processor Windows interface click Start Control Panel 3 Select Device Manager from the list...

Page 52: ...JAI Camera MX U Series Hardware Guide Datalogic Automation Inc 3 26...

Page 53: ...ies processor input and output signals use either cable 606 0675 xx 37 pin D sub Male to Male Cable with terminal block 248 0110 or cable 431 0592 xx 37 pin D sub Male to pigtail with no terminal bloc...

Page 54: ...spection task Interrupt driven inputs are edge triggered and the duration of the input pulse must be longer than the debounce time The active trigger edge rising falling or both input pulse duration a...

Page 55: ...t input Note All connections to inputs must be made using properly grounded shielded cable All inputs are compatible with current sinking output signals There is only one Input Plus Common connection...

Page 56: ...rnal power source is required to power an output load The outputs are merely switches that are open or closed All output connections must use properly grounded and shielded cable Note The Trigger Sign...

Page 57: ...cuit Sinking NOTES To prevent output damage all inductive loads must have noise suppressors connected directly across the load as close to the load as possible This is an internal connection not an ou...

Page 58: ...General Purpose Output Circuit Sinking MX U Series Hardware Guide Datalogic Automation Inc 4 6...

Page 59: ...itch connection and they configure themselves and the communications to suit the environment Input Output The terminal block and cable for connecting MX U Series processor are listed in the table belo...

Page 60: ...he monitor panel port provides RGB DVI and SDL video signals The processor requires a monitor and keyboard when it first starts and to configure the system A VGA cable 5 meters maximum with the approp...

Page 61: ...For cable wire color codes and connection diagrams see U1xx Camera Connection on page 3 5 The last two digits of the part number indicate the cable length in meters Connector Type Part Number Termina...

Page 62: ...U1xx MX U Series Hardware Guide Datalogic Automation Inc 5 4...

Page 63: ...ront 1 7 power 2 5 top 1 6 USB 5 2 VGA 5 2 D Debounce 4 2 Dimensions processor 1 3 2 1 U1xx 3 3 DisplayPort connector 5 2 DVI I connector 5 2 E Ethernet cable 5 1 connector 1 6 status 1 9 F Flash comp...

Page 64: ...4 Specifications processor 1 3 U1xx 3 13 Status lights 1 9 Support technical 1 10 Switch power 1 7 T Technical support 1 10 Temperature range processor 1 3 Terminal block processor 4 1 U1xx 3 5 3 6 T...

Reviews: