background image

MATRIX 450™ QUICK REFERENCE GUIDE 
 

18 

 

6. From 

the 

Focusing and PPI Setup Chart

, select the 1 mm code and position it at the 

center of the Horizontal FOV (aligned with the laser pointers). 

 

 

 

a.  Select a Calibration Mode choice and press the "Calibrate" button. 

 

b.  Select a Code Setting Mode choice and press the "Code Setting" button. 

 
This step performs image density calibration in order for Matrix 450™ to function correctly 
and to the fullest extent of its capabilities. The Setup Result section of the Setup Wizard 
window shows the code type results and the image density calibration settings. 

 

 

 
 

6

Summary of Contents for Matrix 450

Page 1: ...application For other types of installations such as ID NET and for a complete reader configuration using the VisiSet configuration program refer to the Matrix 450 Reference Manual available on the mi...

Page 2: ...which describes specific Info Features Applications Models Accessories and specific Downloads DOWNLOAD PRODUCT LITERATURE SW UTILITIES The VisiSet utility program which allows device configuration usi...

Page 3: ...Remove the sensor protection label by pulling it off of the base 3 Mount the LNS 12xx lens by slowly screwing it onto the base until it arrives at the mechanical stop NOTE The lens mount is equipped...

Page 4: ...nt Lens 5MP with anti vibration components 93A400034 LT 032 ULTRA POWER LT NARROW BLUE 40 93A400032 LT 030 ULTRA POWER LT SUPERNARROW BLUE 20 93A400033 LT 031 ULTRA POWER LT SUPERNARROW WHITE 20 93ACC...

Page 5: ...wn White wires to Vdc and Black Blue wires to GND Connect the cable shield to Earth ground Use CAB MS0x between Matrix 450 and the CBX for power serial host external trigger device photocell serial au...

Page 6: ...ed with the LT 03x is used to supply power to the Matrix 450 from the LT 03x Matrix 450 Standalone Layout to Ethernet Host Matrix 450 LT 03x can also be used in an ID NET Master Slave configuration Se...

Page 7: ...ce I1B External Trigger B polarity insensitive TX Auxiliary Interface TX V Power Reference External Trigger RX Auxiliary Interface RX V Power Source Inputs SGND Auxiliary Interface Reference I2A Input...

Page 8: ...gh the reader can read a code at any tilt angle Assure at least 10 Pitch or Skew to avoid direct illuminator light reflection which will reduce performance 3 Refer to the Reading Diagrams to determine...

Page 9: ...s function by pressing and holding the X PRESS push button until the Focus LED is on Figure 4 X PRESS Interface Focus Function 5 Release the button to enter the Focus function The Blue Diamonds and la...

Page 10: ...e lens type is changed or if the focal distance is changed Locate 1 Enter the Focus function by pressing and holding the X PRESS push button until the Focus LED is on 2 Release the button to enter the...

Page 11: ...X PRESS push button once Learn 8 Enter the Learn function by pressing and holding the X PRESS push button until the Learn LED is on Figure 9 X PRESS Interface Learn Function 9 Release the button to en...

Page 12: ...ing and holding the X PRESS push button until the Setup LED is on Figure 11 X PRESS Interface Setup Function 6 Release the button to enter the Setup function The Setup LED will blink until the procedu...

Page 13: ...ase Matrix 450 emits a long low pitched beep 10 Exit the Learn function by pressing the X PRESS push button once NOTE If you have used this procedure to configure Matrix 450 go to step 9 RESET READER...

Page 14: ...onfiguration running Windows 98 2000 NT 4 0 SP4 or later XP Vista or 7 then insert the VisiSet Mini DVD wait for the CD to autorun and follow the installation procedure This configuration procedure as...

Page 15: ...top Step 1 it can be rotated counterclockwise up to one full turn without loosening the lens so that the diaphragm scale and locking knobs can be easily accessed from behind the LT 03x a Remove the an...

Page 16: ...and on the four delimiters red points in the acquired images which indicate the region in which the calibration algorithm is active See figure below Press the Positioning button again to stop positio...

Page 17: ...the lens a little farther the Current Focus Quality Bar decreases red see middle figure c Rotate the Focusing ring in the opposite direction The Current Focus Quality Bar green increases towards the v...

Page 18: ...a Calibration Mode choice and press the Calibrate button b Select a Code Setting Mode choice and press the Code Setting button This step performs image density calibration in order for Matrix 450 to...

Page 19: ...t of the reader at the same reading distance then repeat step 6a and 6b 8 Select a Saving Options choice and press the Save button 9 Close the Setup Wizard NOTE If your application has been configured...

Page 20: ...LEDs is activated and when codes are placed in the reading area FOV the Bar Graph shows the Good Read Rate In case of no read condition only the STATUS LED is on and blinks Figure 15 X PRESS Interface...

Page 21: ...eing able to complete a detailed reader configuration The desired parameters can be defined in the various folders of the Parameter Setup window and then sent to the reader memory either Temporary or...

Page 22: ...ding TRIGGER yellow LED indicates the status of the reading phase COM yellow LED indicates active communication on the main serial port STATUS red LED indicates a NO READ result When connected to a Fi...

Page 23: ...1 Lighting Systems are especially effective in high speed code movement applications When defining a HW SW configuration for the Matrix 450 LT 03x assembly for conditions different from those of the r...

Page 24: ...032 Software Parameters Exposure Time 10 s 19 25 Max code moving speed 1 8 m s 1 8 m s Gain 13 14 LT 03x Lighting Mode Very High Power Strobed or Continuous High Power Minimum Code Height mm 5 Code 1...

Page 25: ...re Time 10 s 15 16 20 12 12 19 Max code moving speed 1 8 m s 1 8 m s 1 5 m s 2 8 m s 2 8 m s 1 8 m s Gain 7 13 16 8 16 15 LT 03x Lighting Mode Very High Power Strobed or Continuous High Power Minimum...

Page 26: ...osure Time 10 s 12 12 18 16 16 22 Max code moving speed 2 3 m s 2 3 m s 1 5 m s 3 2 m s 3 2 m s 2 5 m s Gain 7 14 16 6 12 16 LT 03x Lighting Mode Very High Power Strobed or Continuous High Power Minim...

Page 27: ...LT 031 Software Parameters Exposure Time 10 s 20 40 15 27 Max code moving speed 1 0 m s 0 5 m s 1 8 m s 1 0 m s Gain 22 22 18 22 LT 03x Lighting Mode Very High Power Strobed or Continuous High Power M...

Page 28: ...2 200 7 87 179 7 05 90 3 54 9 0 35 65 2 56 30 1 18 62 2 44 50 25 27 5 1 08 34 5 1 36 55 2 17 45 1 77 9 0 35 22 5 0 89 42 5 1 67 20 0 79 20 0 79 60 2 36 Figure 18 Matrix 450 LT 03x L Bracket Overall Di...

Page 29: ...itch 35 Tilt 0 360 Lighting System LT 03x Family Illuminators Risk 2 Group LED product to EN62471 Class 2 LED product to IEC60825 1 Laser Safety Class pointers Class 2 Laser Light to IEC60825 1 ENVIRO...

Page 30: ...Japan Post PLANET POSTNET POSTNET BB Intelligent Mail Swedish Post Operating Mode ONE SHOT CONTINUOUS PHASE MODE Configuration Methods X PRESS Human Machine Interface Windows based SW VisiSet via seri...

Page 31: ...and 2 this device must accept any interference received including interference which may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A digi...

Page 32: ...Place the replicate lens and illuminator serial number labels here for reference Some of this information can also be written in the Reader Information configuration parameters in the Miscellaneous f...