background image

ELECTRICAL INTEGRATION

9

   MAGELLAN 3410VSI OEM

Supply Voltages

POS HOST INTERFACE

The POS host can be set to operate in the following interface protocols

• RS232
• USB OEM
• USB COM
• USB Keyboard

Refer to the Magellan 3410VSi Product Reference Guide for details on how to select

these interfaces.

Table 1. POS Host Cable Pinouts

SERVICE PORT INTERFACE

The service port is a high-speed USB device interface adhering to the CDC-ACM USB

device class. It is used to configure the scanner. This port uses a Type-B Micro USB con

-

nector.

NAME

DESCRIPTION

5V-12V DC Input

A dedicated power jack for DC input power. This 

input must be used when an external handheld 

scanner is attached to the Aux port. Please use 

only Datalogic brand power supply.

5V USB Input

5V DC provided by the POS connector when the 

USB interface is in use. Note that the USB inter

-

face will only supply enough power for the 3410 

OEM. If an auxiliary device (handheld) is con

-

nected, power must be provided via the 5V-12V 

DC input jack.

PIN #

RS-232

USB-OEM

USB, USB 

KEYBOARD, 

USB COM

NOTES

1

D+

D+

USB Data+

2

CTS

RS232 CTS input

3

D-

D-

USB Data-

4

RTS

RS232 RTS output

5

RXD

RS232 RXD input

6

TXD

RS232 TXD output

7

8

VIN

VIN/BUS

VIN/BUS

5V DC input - must be limited to 

5V

9

GND

GND

GND

Ground

10

ERI

ERI

ERI

External read indicator output

Summary of Contents for MAGELLAN 3410VSi

Page 1: ...Magellan 3410VSi OEM INTEGRATION GUIDE Omni Directional Imaging Scanner...

Page 2: ...te www datalogic com If you visit our website and would like to make comments or suggestions about this or other Datalogic pub lications please let us know via the Contact page Disclaimer Datalogic ha...

Page 3: ...5 Design of the Scanner Opening 5 Housing Design 6 Mounting Holes 6 Integrating the Scanner Behind a Window 6 Scanner Clearance for Integration 6 Exit Window Clearance 7 CHAPTER 3 ELECTRICAL INTEGRATI...

Page 4: ...Ds in the scanner emit visi ble light as well as invisible infrared light When a bar code passes through the scan vol ume area light is reflected off the bar code The scanner collects this reflected l...

Page 5: ...technical assistance and information is an authorized Datalogic reseller A reseller is acquainted with specific types of businesses application software and computer systems and can provide individua...

Page 6: ...3410VSi Product Reference Guide Figure 1 1 Scanner block diagram BEEPER INDICATORS The scanner s beeper sounds to indicate various functions or errors on the scanner Refer to the 3410VSi Product Refer...

Page 7: ...reference the following section MOUNTING System integration is made easy with the OEM scanner s mounting features Four mounting holes are located on the front of the scanner for use with size M3 scre...

Page 8: ...e scanner is flush against the opening it should be the size of the scanner window at a minimum but only exposing as much of the front surface of the scanner as necessary Additional clearance in the o...

Page 9: ...e electrically grounded Static discharge ESD testing is recommended for the entire system integration to ensure proper ESD protection Proper ESD protection should be used at the time of installation a...

Page 10: ...s of the host enclosure must not enter the Field of View of the scanner The enclosure wall thickness should not exceed 0 38 in to prevent clipping of the FoV as shown in Figure 2 2 on page 7 Figure 2...

Page 11: ...res such as operating in a properly grounded working area using wrist straps ELECTRICAL INTERFACE The scanner can be connected to various interfaces supporting Bar code data and commands via the host...

Page 12: ...12V DC Input A dedicated power jack for DC input power This input must be used when an external handheld scanner is attached to the Aux port Please use only Datalogic brand power supply 5V USB Input...

Page 13: ...elow for the SDA 2 0 specification Both FAT16 and FAT32 formats are supported Filenames are limited to the 8 3 file naming format i e FILENAME EXT and MUST be capitalized MicroSD Function Summary The...

Page 14: ...1 MP 1280 X 800 Scan Rate 30 Frames second Read Height 14 0 cm 5 5 in Minimum Resolution 5 mil Minimum Print Contrast Ratio 25 Reading Angle Pitch 65 Roll Tilt 0 360 Skew Yaw 75 PARAMETER SPECIFICATIO...

Page 15: ...an only be applied to the DC input power port Power Consumption Maximum Typical RMS Sleep Mode RMS 2 25W 5V 3 3W 12V 1 6W 5V 2 1W 12V 0 95W 5V 1 25W 12V PARAMETER SPECIFICATION Scanalyzer Magellan Sca...

Page 16: ...gellan 3410VSi OEM APPENDIX B MECHANICAL SPECIFICATIONS PHYSICAL CHARACTERISTICS Figure B 1 Scanner dimensions PARAMETER SPECIFICATION Dimensions 12 7 x 14 4 x 7 8 cm 5 x 5 7 x 3 1 in Weight 0 3 kg 0...

Page 17: ...INTEGRATION GUIDE 14 MOUNTING TEMPLATE The Mounting Template in the following page shows the mounting holes for the scan ner NOTE the Mounting Template drawing must be printed actual size to ensure p...

Page 18: ...86 PP 25 7 11 5 0 7 5 72 92 33 1 2 6 1 3 77 51 02817 1 7 03 7 35 17 7 6 3 7 6...

Page 19: ......

Page 20: ...t no part of this documentation may be reproduced stored in or introduced into a retrieval system or transmitted in any form or by any means or for any purpose without the express written permission o...

Reviews: