Enter/Exit Programming Mode
56
Magellan™ 3200VSI
ACK NAK Retry Count
This feature sets the number of times for the scanner to retry a label transmission under a retry condition.
000 = No retry
001 - 254 = Retry for the specified number of times
255 = Retry forever
To configure this feature, scan the “Enter/Exit Programming Mode” bar code above to place the unit in Programming
Mode, then the “Set ACK NAK Retry Count,” followed by the three digits (zero padded) from the Alphanumeric table in
representing your desired retry count. Exit programming mode by again scanning the “Enter/Exit Pro-
gramming Mode” bar code above
DEFAULT SETTING FOR THIS FEATURE: 003
Set ACK NAK Timeout Value
ACK NAK Error Handling
This item specifies the method the scanner will use to handle errors detected
while waiting to receive the ACK character from the host. Errors include unrec-
ognized host commands and communication errors such as parity or framing
errors. Choices are:
00 = Ignore errors detected (recommended setting)
01 = Process error as valid ACK character (risk of lost label data)
02 = Process error as valid NAK character (risk of duplicate label data)
Ignore Errors Detected
DEFAULT
Process error as valid ACK character
Process error as valid NAK character
Summary of Contents for MAGELLAN 3200VSI
Page 1: ...Magellan 3200VSi Product Reference Guide...
Page 16: ...8 Magellan 3200VSI NOTES...
Page 40: ...Enter Exit Programming Mode 32 Magellan 3200VSI Wake Up Intensity continued 13 14 15...
Page 46: ...Enter Exit Programming Mode 38 Magellan 3200VSI NOTES...
Page 80: ...USB COM Interface Setup 72 Magellan 3200VSI NOTES...
Page 92: ...Enter Exit Programming Mode Character Conversion 84 Magellan 3200VSI NOTES...
Page 163: ...Product Reference Guide 155 Appendix C A B C D E F Alpha Numeric Pad...
Page 180: ...172 Magellan 3200VSI NOTES...
Page 182: ...174 Magellan 3200VSI NOTES...
Page 192: ...184 Magellan 3200VSI NOTES...