LYNX™ BT
4
4.3.4 Mismatch
Result
The result of each format may be set in case the match conditions previously
selected are not satisfied.
Example
Once the desired formats have been enabled and a code has been read, the results
corresponding to each format will be concatenated together and transmitted in the
output message. For this reason, it is strongly advised to set the mismatch result for
each format.
Format
Enable/Disable Match Condition
Function
Decoded Code
: <DATALOGICproduct>
Format definition
:
Mismatch Result
Format 1 Enabled
Select field from
position1 to
position3
No string
Code having a length
of 16 characters
Format 2
/
/
Disabled
/
Format 3 Enabled
Substitute string
"ab" with string
"12"
Unformatted read
code
Code having a length
of 25 characters
Format 4
t string
7
Enabled
Code
having
the
substring "AT" in
position 2
Inser
"789" in position
Unformatted read
code
Format 5
Delete string
"DA" and "pr"
Enabled
Code belonging to the
PDF417 symbology
Unformatted read
code
Output message
: <DATDATALOGICproductDATALO789GICproductDATALOGICproduct>
Format 1 Format 3
Format 4
Format 5
Define Mismatch Result
Read the above code and:
1. read a number in the range
1-5
corresponding to the
desired format number;
2.
0 = empty string as output
1 = unformatted read code as output.
Mismatch Result
AOCLFLHODNGNENEIEPANHOGOCK
AHPNIJAMDKEOFMHMLJAKEFGEIK
AKCBPJCJGIIJCMCFHPJPBJONNK
AEFBJLBGMHPKMJGONHLFIIIHGK
AAPHBAJJCDBDNKDEDGEINLGHBK
AFLFAMLJPMLKOLLPNDLGCBAIIK
DLDLLDLDDLLLLLLDDDLDDLDLDL
128
Summary of Contents for lynx bt
Page 1: ...Lynx BT Reference Manual...
Page 2: ......
Page 3: ...Lynx BT REFERENCE MANUAL...
Page 12: ...GENERAL VIEW LYNX BT OM 1000 BT Radio Connection est Button Status LEDs T x...
Page 20: ...xviii...
Page 200: ...AUTOSCAN PATTERN CODE s...