DIAGNOSTICS
90
SAFERY LASER SCANNER
OVERRIDE
NORMAL
ON
The Override function is active
OVERTEMP
NORMAL
ON
The external temperature is above
the limit.
OVR TIMEOUT
NORMAL
ON
The Override timeout function has
expired.
HIGH REFL-BKG
NORMAL
ON
A high reflecting background is
detected that could have an impact
on detection capability. Take the
measures described in "
for Environmental Interference" on
page 11
or reduce/remove the
reflecting background.
CHECK MASTER
NORMAL
ON
The Slave unit warns against a
problem on the Master device.
WINDOW REPLACE
NORMAL
OFF
Window replacement procedure in
progress.
COMMIT ON FIELD
NORMAL
OFF
The device needs a commit when it
has been restored on field after
window replacement.
SHUT-OFF
NORMAL
OFF
Shut Off function enabled.
RES SHUT-OFF
NORMAL
OFF
Shut Off function disabled.
WAITING CONF
LOCKOUT
OFF
The device is waiting the first con-
figuration (e.g. after a Factory
Reset)
DISPLAYED
ICON
DISPLAYED
FAULT CODE
DEVICE
STATUS
OSSD
STATUS
DESCRIPTION
Summary of Contents for Laser Sentinel