Default Settings
The following tables contain the default values for the major barcode setup
parameters, according to the type of scan engine mounted on the PDA. For a
complete list of parameters and of their configuration procedures, please refer to the
SDK Help file on the CD.
SCAN PARAMETERS
HP Laser
Imager
RFID+Laser
ScanTimeout 5000
Not
available 5000
GoodReadSound Beep.wav
Beep.wav
Beep.wav
LedDuration
200 ms
200 ms
200 ms
LedPulses 1
1
1
ContinuousMode Disabled
Disabled
Disabled
KeyboardEmulation Disabled
Disabled
Disabled
SoftTrigger Enabled
Enabled
Enabled
ScanAlwaysOn Disabled
Disabled
Disabled
NotPrintableChar Leave
Leave
Leave
ScanButton Enabled
Enabled
Enabled
BARCODE SYMBOLOGY
SPECIFIC
READER PARAMETERS
HP Laser
Imager
RFID+Laser
UPC A
Enabled Enabled
UPC E
Enabled Enabled
EAN 8
Enabled Enabled
EAN 13
Enabled
*
Enabled
UPC E1
Disabled
EAN Bookland
Disabled
UPC/EAN/JAN
Enabled
Code 39
Enabled Enabled Enabled
Code 39 Full ASCII
Disabled Disabled Disabled
Code 32
Disabled
Disabled
Code 39 Trioptic
Disabled
2/5: Interleaved
Enabled Enabled Enabled
2/5: Industrial
Disabled
Disabled
2/5: Matrix
Disabled
Code 128
Enabled Enabled Enabled
EAN 128
Enabled Disabled
Enabled
ISBT 128
Disabled
Codabar
Enabled Enabled Disabled
RSS
Disabled
* In the Imager models these codes may only be enabled or disabled as a group by the
UPC/EAN/JAN family selection (see a few lines below).