RS-232/USB-Com Interfaces
Enter/Exit Programming Mode
Product Reference Guide
51
ACK NAK Timeout Value
This option specifies the amount of time the reader waits for an ACK character from the host following label
transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A
selection of 0 disables the timeout.
See
for more information on setting this feature.
ACK NAK Retry Count
This feature specifies the number of times the reader retries a label transmission due to a retry condition. The
selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies
unlimited retries. See
for more information.
Select ACK NAK Timeout Value Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the
bar code at left followed by the digits from the
Alphanumeric characters in
representing your desired character(s). End by
scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
CANCEL
Select ACK NAK Retry Count Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the
bar code at left followed by the digits from the
Alphanumeric characters in
representing your desired character(s). End by
scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
CANCEL
$CR2AT
~
DEFAULT
01 ACK NAK Timeout value is 200ms
$CR2AR
~
DEFAULT
003 = 3 Retries
Summary of Contents for Gryphon Series
Page 43: ...Enter Exit Programming Mode Global Interface Features 40 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 57: ...Enter Exit Programming Mode RS 232 USB Com Interfaces 54 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 235: ...232 Gryphon I GD44XX GBT4400 GM440X NOTES...