background image

Error Codes

38

Gryphon™ I GBT4100 

Error Codes

Upon startup, if the reader sounds a long tone, this means the 
reader has not passed its automatic Selftest and has entered FRU 
(Field Replaceable Unit) isolation mode. If the reader is reset, the 
sequence will be repeated. The following table describes the LED 
flashes/beep codes associated with an error found.

Label Program-
ming Mode 
Acceptance of 
Programming

Configuration 
option(s) have 
been successfully 
programmed via 
labels and the 
reader has exited 
Programming 
Mode.

N/A

Reader sounds 
one high fre-
quency beep and 
4 low frequency 
beeps followed 
by reset beeps.

Label Program-
ming Mode Can-
cel Item Entry

Cancel label has 
been scanned.

N/A

Reader sounds 
two times at low 
frequency and 
current volume.

a. Except when in sleep mode or when a Good Read LED Duration other than 00 

is selected

NUMBER OF 

LED 

FLASHES/

BEEPS

ERROR

CORRECTIVE ACTION

1

Configuration

Contact Helpdesk for 

assistance

2

Interface  PCB

4

Reader Module

5

Laser Pointer (if so 

equipped)

6

Digital  PCB

14

CPLD/Code Mismatch

INDICATION

DESCRIPTION

LED

BEEPER

Summary of Contents for Gryphon I GBT4100

Page 1: ...Gryphon I GBT4100 General Purpose Handheld Linear Imager Barcode Reader with Bluetooth Wireless Technology Quick Reference Guide ...

Page 2: ...e www datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Datalogic publications please let us know via the Contact Datalogic page Disclaimer Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate however Datalogic reserves the right to change any specificatio...

Page 3: ... Typical Setup with Cradle and Host 18 Selecting the Interface Type 18 Interface Selection 18 Configuring the Interface 18 Keyboard Interface 21 Scancode Tables 23 Country Mode 23 Caps Lock State 28 Numlock 29 BT HID ALT Mode 30 Programming 31 Using Programming Barcodes 31 Configure Other Settings 31 Resetting Standard Product Defaults 31 Stand Detection 32 Technical Specifications 33 LED and Beep...

Page 4: ...NOTES ...

Page 5: ...al Proprietary Information does not include any information that the receiving party can establish was 1 in the public domain 2 already in the receiving party s possession or rightfully known prior to receipt 3 rightfully learned from a third party not in violation of any other s proprietary rights or 4 independently developed without access to Proprietary Information 1 4 Datalogic Product means t...

Page 6: ... End User s internal business purposes End User shall take steps to protect the Proprietary Information no less securely than if it were End User s own intellectual prop erty 5 3 The provisions of this Proprietary Information Section shall survive and con tinue for five 5 years after the termination of this Agreement 6 Limited Warranty 6 1 Datalogic warrants that under normal use and operation the...

Page 7: ...D PARTY FOR LOST PROFITS LOST DATA INTERRUPTION OF BUSINESS OR SERVICE OR FOR ANY OTHER SPECIAL CONSEQUENTIAL CONTINGENT INDIRECT INCIDENTAL PUNITIVE EXEMPLARY OR OTHER SIMILAR DAMAGES EVEN IF DATALOGIC HAS BEEN ADVISED OF THE POSSIBIL ITY OF SUCH DAMAGES 9 Government Restricted Rights International Use 9 1 Use duplication or disclosure of the Software by the U S Government is sub ject to the rest...

Page 8: ...rneys Fees In the event an action is brought to enforce the terms and condi tions of this Agreement the prevailing party shall be entitled to reasonable attorneys fees both at trial and on appeal END Software Product Policy Datalogic reserves the right to ship its products with the latest version of software firmware available This provides our custom ers with the very latest in Datalogic software...

Page 9: ... either a horizontal or standing position in order to provide the most comfortable use depending on needs Changing the Base Station Position The base station is configured by installing one of two sets of me chanical parts that come with the cordless kit The default mounts shown below provide three options vertical wall mounting standing 45 or horizontal mounting with a higher mechanical retention...

Page 10: ...ired base station position as shown below 2 Using your thumbs push open the plastic tabs on the bottom of the base to free the wing holders To ensure best contact and performance do not intermix the parts of the two different mount sets Standing Horizontal Horizontal or Vertical Only Tab Tab ...

Page 11: ...se Station Base Station Connection and Routing Fully insert the Power Ca ble and Interface I F Cable connectors into their respective ports in the underside of the Base Station see Figure 1 Then connect to an AC Adapter and plug the AC power cord into the wall outlet Gryphon BT can also be Powered by the Terminal When powered by the Terminal the battery charger is automati cally set as Slow charge...

Page 12: ...of the power cord can be changed to ac commodate the base station positioning horizontal stand or wall mounting The cables can be looped around to the front of the Base Station or fed directly out the back of the Base Station as shown in Figure 2 on page 8 Figure 2 Options for routing the DC cord Please refer to the arrows depicted on the bottom of the base when placing the cables detailed in Figu...

Page 13: ...d Wedge interface cables have a Y connection where its female end mates with the male end of the cable from the keyboard and the remaining end at the keyboard port on the terminal PC Figure 4 Connecting to the Host The Gryphon I GBT4100 can be set up to require a PIN code when connecting to the host If you are adding new equip ment to a system that uses a custom security PIN please see the PRG for...

Page 14: ...et Disconnecting the Cable To detach the cable insert a paper clip or similar object into the hole on the base as shown in Figure 5 Figure 5 Disconnecting the Cable Using the BC40xx Radio Base Radio Base LEDs LEDs on the Gryphon I Base provide information about the Bases well as battery charging status as shown in Figure 6 Figure 6 Gryphon I Base LEDs Insert Paper Clip YELLOW LED RED LED GREEN LED...

Page 15: ...e cradle it will sound a chirp to indicate that the cradle has detected the scanner connection The LEDs on the base shown in Table 1 will indicate the sta tus of the battery LED STATUS Power on Data Yellow On Base is powered Yellow Blinking Base receives data and commands from the Host or the Reader Charging Red On the Battery is charging Charge completed Green On the Battery is completely charged...

Page 16: ...sitive terminal and nega tive terminal of the battery pack to each other with any metal object such as wire Do not carry or store the battery pack together with metal objects Donotpiercethebatterypackwithnails strikeit with a hammer step on it or otherwise subject it to strong impacts or shocks Do not solder directly onto the battery pack Do not expose the battery pack to liquids or allow the batt...

Page 17: ...e cars in hot weather Doing so may cause the battery to generate heat explode or ignite Using the battery in this manner may also result in a loss of performance and a shortened life expec tancy Do not place the battery in microwave ovens high pres sure containers or on induction cookware Immediately discontinue use of the battery if while using chargingorstoringthebattery thebatteryemits an unusu...

Page 18: ...e in comply with European Directive 2006 66 EC 2011 65 EU 2002 96 EC 2012 19 EU and subsequent modifications US and China regulatory and others laws and regulations about the environment Replacing the Batteries Use the following procedure to change the reader s battery 1 With a screwdriver unscrew the battery cover screw 2 Unplug the three screws securing the battery holder and unplug the white co...

Page 19: ...w 4 Remove the old battery from its place if present and insert the new battery in the same position 5 Replace the battery holder plug in the connector and return the contacts circuit to its previous location 6 Insert the cover in the handle and screw it back into place When inserting the new battery into the handle take care to position the battery and the connector as shown Pass through hole Gol...

Page 20: ...y drivers provided with the Bluetooth adapter 2 Scan the Enable RF Link to Server label below to make the scanner visible to the host computer 3 Use the host computer s Bluetooth manager to Discover new devices and select Datalogic Scanner If you receive an error message it may be necessary to disable security on the device 4 Use an RS 232 terminal program to see incoming data on the port designat...

Page 21: ... the PC Use a text editor to see incoming data from the reader Link to a PC in HID Use Variable PIN Code When you hear the beep and see the Green LED blinking indicat ing the reader is waiting for an alphanumeric entry enter the vari able PIN Code by scanning the bar code s corresponding with the required PIN Code from Keypad starting on page 50 SomeBluetoothdriversontheHost suchasWIDCOMMand BlueS...

Page 22: ...ct your system s correct interface type Interface Selection Each reader model will support one of the following sets of host interfaces General Purpose Models RS 232 RS 232 OPOS USB Key board Wedge Wand Retail Point of Sale Models RS 232 RS 232 OPOS USB IBM 46XX Information and programming options for each interface type are provided in this section Configuring the Interface Scan the programming b...

Page 23: ...e interfaces require the scanner to start in the dis abled state when powered up If additional scanner con figuration is desired while in this state pull the trigger and hold for 5 seconds The scanner will change to a state that allows programming with barcodes RS 232 RS 232 standard interface Select RS232 STD RS 232 Wincor Nixdorf Select RS232 WN RS 232 for use with OPOS UPOS JavaPOS Select RS 23...

Page 24: ...on IGBT4100 IBM IBM 46xx Port 5B reader interface Select IBM P5B IBM 46xx Port 9B reader interface Select IBM P9B USB OEM USB OEM can be used for OPOS UPOS JavaPOS Select USB OEM a Download the correct USB Com driver from www datalogic com ...

Page 25: ...OARD AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Standard Key Encoding Select KBD AT KeyboardWedgeforIBMATPS2withstandardkeyencodingbutwithoutexternal keyboard Select KBD AT NK AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Alternate Key Select KBD AT ALT Keyboard Wedge for IBM AT PS2 withalternate key encoding but withoutexter nal keyboard Select KBD AT ALT NK ...

Page 26: ...nal 3153 Select KBD IBM 3153 Keyboard Wedge for IBM Terminals 31xx 32xx 34xx 37xx make only keyboard Select KBD IBM M Keyboard Wedge for IBM Terminals 31xx 32xx 34xx 37xx make break keyboard Select KBD IBM MB Keyboard Wedge for DIGITAL Terminals VT2xx VT3xx VT4xx Select KBD DIG VT USB Keyboard with standard key encoding Select USB Keyboard ...

Page 27: ...0 70 80 90 95 w Std Key Encoding Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 without Alternate Key Keyboard Wedge for IBM AT PS2 without alternate key encoding but without external keyboard Bluetooth HID Profile All other interfaces support ONLY the following Country Modes U S Belgium Britain France Germany Ital...

Page 28: ...hon IGBT4100 COUNTRY MODE ENTER EXIT PROGRAMMING MODE Country Mode U S Country Mode Belgium Country Mode Britain Country Mode Croatia Country Mode Czech Republic Supports only the interfaces listed in the Country Mode feature description ...

Page 29: ...nce Guide 25 COUNTRY MODE continued Country Mode Denmark Country Mode France Country Mode French Canadian Country Mode Germany Country Mode Hungary Country Mode Italy Supports only the interfaces listed in the Country Mode feature description ...

Page 30: ... Gryphon IGBT4100 COUNTRY MODE continued Country Mode Japanese 106 key Country Mode Lithuanian Country Mode Norway Country Mode Poland Country Mode Portugal Supports only the interfaces listed in the Country Mode feature description ...

Page 31: ...Quick Reference Guide 27 COUNTRY MODE continued Country Mode Romania Country Mode Slovakia Country Mode Spain Country Mode Sweden Country Mode Switzerland Supports only the interfaces listed in the Country Mode feature description ...

Page 32: ... which the reader sends charac ter data This applies to keyboard wedge interface and Bluetooth HID Profile It does not apply when an alternate key encoding keyboard is selected ENTER EXIT PROGRAMMING MODE Caps Lock State Caps Lock OFF Caps Lock State Caps Lock ON Caps Lock State AUTO Caps Lock Enable ...

Page 33: ...ption specifies the setting of the Numbers Lock Numlock key while in keyboard wedge interface This only applies to alter nate key encoding interfaces It does not apply to USB keyboard ENTER EXIT PROGRAMMING MODE Numlock Numlock key unchanged Numlock Numlock key toggled ...

Page 34: ...HID ALT Mode This feature Enables Disables the ability to transmit correctly a la bel content to the host regardless the BT HID Country Mode se lected when BT HID profile is configured ENTER EXIT PROGRAMMING MODE HID ALT Mode Disable HID ALT Mode Enable ...

Page 35: ... Scan an ENTER EXIT barcode once to enter Programming Mode scan the desired parameter set tings scan the ENTER EXIT barcode again to accept your changes which exits Programming Mode and returns the reader to normal operation Configure Other Settings Additional programming barcodes are available in the Gry phon I PRG to allow for customizing programming features If your installation requires differ...

Page 36: ...e scanner to Stand Mode when the scanner is placed in the stand Switch to Flashing Automatically switches the scanner to Flash Mode when the scanner is placed in the stand Switch to Always On Automatically switches the scanner to Al ways On mode when the scanner is placed in the stand Ignore Autorecognition Disables mode switching when the scan ner is placed in a stand Switch to Stand Mode Switch ...

Page 37: ...i Ion battery pack Typical charge time for full charge from full discharge 4 hours with 12V external power supply adaptera Max 22 hours with Host power in this case no supply adapter is needed a Operating autonomy continuous reading 30 000 reads typical Cradle consumption and DC input supply range Volt 4 75 14 VDC Power 8Wb Imax 500mA when in host bus powered modeb Performance Characteristics Ligh...

Page 38: ...board Digital Terminals VT2x VT3xx VT4xx and Apple and Wand Emulation User Environment Operating Temperature 32 to 122 F 0 to 50 C Charging Temperature 32 to 104 F 0 to 40 C Storage Temperature 4 to 158 F 20 to 70 C Humidity Operating 5 to 90 relative humidity non condensing Drop Specifications Scanner withstands 18 drops from 1 8 meters 5 9 feet to concrete Ambient Light Immunity Up to 100 000 Lu...

Page 39: ...ty UL 60950 CSA C22 2 No 60950 IEC 60950 EMI RFI Obtained Europe CE Australia C tick Russia GOST USA CANADA FCC IC Japan JRF VCCI Mexico NOM Cofetel South Korea KCC Brazil ANATEL Argentina CNC LED class safety IEC Class 1 Radio Features Frequency Range 2400 to 2483 5 MHz Range in open air 30 m ...

Page 40: ... powering up N A Reader beeps four times at highest fre quency and vol ume upon power up Good Read Beep A label has been successfully scanned by the reader LED behavior for this indica tion is configu rable via the feature Good Read When to Indicate seethePRGfor information The reader will beep once at cur rent frequency volume mono bi tonal setting and duration upon a success ful label scan ROM F...

Page 41: ...The following indications ONLY occurwhen the reader is in Programming Mode Label Program ming Mode Entry A valid program ming label has been scanned LED blinks con tinuously Reader sounds four low fre quency beeps Label Program ming Mode Rejection of Label A label has been rejected N A Reader sounds three times at lowest fre quency and cur rent volume Label Program ming Mode Acceptance of Partial ...

Page 42: ...been successfully programmed via labels and the reader has exited Programming Mode N A Reader sounds one high fre quencybeepand 4 low frequency beeps followed by resetbeeps Label Program ming Mode Can cel Item Entry Cancel label has been scanned N A Reader sounds two times at low frequency and current volume a Except when in sleep mode or when a Good Read LED Duration other than 00 is selected NUM...

Page 43: ...llow LED blinking 1Hz Data labels are transmitted to the HOST Yellow LEDs turned off for 100mSec Programming Mode Yellow LED blinks quickly ConfigurationalignmentwiththeHHisin progress Red LED blinks quickly Battery charger in progress Red LED on Battery charger complete Green LED on Battery charger error Green LED and Red LEDs blink alternatively 1Hz No HH is placed on the cradle Red and Green LE...

Page 44: ...sted and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio ...

Page 45: ...e bruits radioelec triques depassant les limites applicables aux appareils numeriques de la classe B prescrites dans le Reglement sur le brouillage radio electrique edicte par le ministere des Communications du Cana da Power Supply This device is intended to be connected to a UL Listed CSA Cer tified computer which supplies power directly to the reader or else be supplied by UL Listed CSA Certifie...

Page 46: ...cto es usable en Mexico Certificado Nr RCPDADL09 1251 COFETEL La operación de este equipo está sujeta a las siguientes dos condiciones 1 es posible que este equipo o dispositivo no cause interferencia perjudicial y 2 este equipo o dispositivo debe aceptar cualquier interferencia incluyendo la que pueda causar su operación no deseada Este equipamento opera em caráter secundário isto é não tem direi...

Page 47: ...PBB Polybrominated diphenyl ethers PBDE Ქ ኂ 凝ᚗర PART ㇱઙฬ 卋 ᳮ 叏 ચ卲 ᄙᄽ侶 ᄙᄽԲ ㅘ Printed Circuit Board Assembly 䏃ᵓ㒘ӊ X O O O O O Assy Optics Block ܝ ᄺ㒘ӊ X O O O O O Assy Module ܝ ᄺ㒘ӊ X O O O O O O ઍ ᱝẊㇱઙ ᚲ ဋ凝 ޗ றխࢬܶऱ具Ẋ ڶ ڶ ୭ढ凝 Պխ䦀Գ ا ٥ࡉ㧺ॾஒ䣈䢓ຝᚲ咒ؒ ޝ 䶣 ॾஒ䣈 խ ڶ ڶ ୭ढ凝ऱૻၦ ޣ ρ SJ T 11363 2006 億ࡳऱૻၦ ޕ X ઍ ᱝẊㇱઙᚲ ဋ凝 ޗ றխ ዋ 㮕 ᢱ ᚲ Ქ ኂ 凝 Պխ䦀Գ ا ٥ࡉ㧺ॾஒ䣈䢓ຝᚲ咒ؒ ޝ 䶣 ॾஒ䣈 խ ڶ ڶ ୭ढ凝ऱૻၦ ޣ ρ SJ T 11363 2006 億ࡳऱૻ ...

Page 48: ...minated biphenyls PBB Polybrominated diphenyl ethers PBDE Ქ ኂ 凝ᚗర PART 卋 ᳮ 叏 ચ卲 ᄙᄽ侶 ᄙᄽԲ ㅘ Printed Circuit Board Assembly 䏃ᵓ㒘ӊ X O O O O O Assy Module ܝ ᄺ㒘ӊ X O O O O O O ઍ ᱝẊㇱઙ ᚲ ဋ凝 ޗ றխࢬܶऱ具Ẋ ڶ ڶ ୭ढ凝 Պխ䦀Գ ا ٥ࡉ㧺ॾஒ䣈䢓ຝᚲ咒ؒ ޝ 䶣 ॾஒ䣈 խ ڶ ڶ ୭ढ凝ऱૻၦ ޣ ρ SJ T 11363 2006 億ࡳऱૻၦ ޕ X ઍ ᱝẊㇱઙᚲ ဋ凝 ޗ றխ ዋ 㮕 ᢱ ᚲ Ქ ኂ 凝 Պխ䦀Գ ا ٥ࡉ㧺ॾஒ䣈䢓ຝᚲ咒ؒ ޝ 䶣 ॾஒ䣈 խ ڶ ڶ ୭ढ凝ऱૻၦ ޣ ρ SJ T 11363 2006 億ࡳऱૻ ...

Page 49: ...operations Contacts on the scanner and the base should also be cleaned as needed to ensure a good connection Use a soft dry cloth to clean the product If the product is very soiled clean it with a soft cloth moistened with a diluted non ag gressive cleaning solution or diluted ethyl alcohol CAUTION Do not use abrasive or aggressive cleansing agents or abra sive pads to clean scan windows contacts ...

Page 50: ...ationen zur Entsorgung von Elektro und Elektronik Altgeräten WEEE erhalten Sie auf der Webseite www datalogic com Spanish Si desea información acerca de los procedimientos para el desecho de los residuos del equipo eléctrico y electrónico WEEE visite la página Web www datalogic com Portuguese Para informações sobre a disposição de Sucatagem de Equipamentos Elétricos e Eletrônicos WEEE Waste Electr...

Page 51: ...he time of the repair other than the firmware or software installed during the manufacture of the product Customer ac cepts responsibility to maintain a back up copy of its software and data Warranty Claims Process In order to obtain service under the Factory Warranty Customer must notify Datalog ic of the claimed defect before the expiration of the applicable Warranty period and obtain from Datal...

Page 52: ...IVE REMEDY FOR WAR RANTY CLAIMS UNDER NO CIRCUMSTANCES WILL DATALOGIC BE LIABLE TO CUSTOMER OR ANY THIRD PARTY FOR ANY LOST PROFITS OR ANY IN CIDENTAL CONSEQUENTIAL IN DIRECT SPECIAL OR CONTINGENT DAMAG ES REGARDLESS OF WHETHER DATALOGIC HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES Risk of Loss Customer shall bear risk of loss or damage for product in transit to Datalogic Data logic shall...

Page 53: ...atalogic Aladdin a multi platform utility program that allows device configuration using a PC It provides RS 232 interface configuration as well as configuration bar code printing Service Support Technical Support Product documentation and pro gramming guides and Technical Support Department in the world Service Programs Warranty Extensions and Mainte nance Agreements Repair Services Flat Rate Rep...

Page 54: ...ld select digits characters from a keypad If you make a mistake scan the CANCEL barcode below to abort and not save the entry string You can then start again Cancel an incomplete HID Variable PIN Code Finish by scanning the Exit HID Variable PIN Code label Exit HID Variable PIN Code 0 1 2 3 ...

Page 55: ...Keypad Quick Reference Guide 51 4 5 6 7 8 9 ...

Page 56: ...Keypad 52 Gryphon IGBT4100 NOTES ...

Page 57: ...Keypad Quick Reference Guide 53 NOTES ...

Page 58: ...Keypad 54 Gryphon IGBT4100 NOTES ...

Page 59: ...n folgenden Normen entspricht Esta declaración se basa en el cumplimiento de los productos con las siguientes normas Datalogic ADC Srl Via S Vitalino 13 Lippo di Calderara di Reno BO 40012 Italy EC 062 Rev 3 Pag 1 di 1 e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos ETSI EN 301 489 17 V2 1 1 MAY 2009 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTR...

Page 60: ...nd the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U Datalogic ADC Inc 959 Terry Street Eugene OR 97402 USA Telephone 1 541 683 5700 Fax 1 541 345 7140 www datalogic com 820051114 Rev E October 2013 ...

Reviews: