Scanning Features
Product Reference Guide
317
Flash Off Time
This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable
range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with
leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Go to
and scan the ENTER/EXIT PROGRAMMING MODE barcode to
enter Programming Mode.
4. Scan the barcode: SELECT FLASH OFF TIME SETTING.
5. Scan the appropriate two digits from the keypad in
, that represent
the duration which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the begin-
ning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
for some examples of how to set this feature.
Table 44. Flash Off Time Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
500ms
1,000ms (1 sec.)
5200ms (5.2 sec.)
9,900ms (9.9 sec.)
2
Divide by 100 (and pad with
leading zeroes to yield two
digits)
05
10
52
99
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT FLASH OFF TIME SETTING
5
Scan Two Characters From
‘0’ and ‘5’
‘1’ and ‘0’
‘5’ and ‘2’
‘9’ and ‘9’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for Gryphon BT4100
Page 56: ...ENTER EXIT PROGRAMMING MODE 54 Gryphon I GD4100 GM4100 GBT4100 L GD4300 NOTES ...
Page 288: ...Other BT Features 286 Gryphon I GD4100 GM4100 GBT4100 L GD4300 NOTES ...
Page 324: ...References 322 Gryphon I GD4100 GM4100 GBT4100 L GD4300 NOTES ...
Page 336: ...Technical Specifications 334 Gryphon I GD4100 GM4100 GBT4100 L GD4300 NOTES ...
Page 352: ...Sample Bar Codes 350 Gryphon I GD4100 GM4100 GBT4100 L GD4300 NOTES ...
Page 355: ...Keypad Product Reference Guide 353 A B C D E F ...
Page 356: ...Keypad 354 Gryphon I GD4100 GM4100 GBT4100 L GD4300 NOTES ...
Page 366: ...Scancode Tables 364 Gryphon I GD4100 GM4100 GBT4100 L GD4300 NOTES ...