GRYPHON™ BT
90
5
5.2 READING
PARAMETERS
5.2.1 Operating
Mode
This group of parameters allows setting different reading modes for either Hand-Held
operation or Stand operation:
•
SoftwareTrigger: the reader is set in FLASH MODE. Code reading takes place
during the
flash on
time;
•
Hardware Trigger: the code reading is started with a trigger press (ON);
•
Hardware Trigger Ready: the illuminator is switched ON when the reader sees a
code. It functions as a pointer aiming at the code to be read. The reading phase
starts only when the trigger is pressed. In this mode the reader is automatically
set to
trigger active level
and
one read per cycle
parameters. (Only for Hand-
held operation).
•
Automatic: The illuminator is switched ON when the reader sees a code. The
reading phase starts automatically.
5.2.2
Hardware Trigger Mode
This mode determines how the reading phase is controlled when the hardware
trigger operating mode is selected:
•
trigger active level: the reader goes ON when the trigger is pressed and goes
OFF when it is released
•
trigger active pulse: the reader goes ON at the first trigger press and goes OFF
only at a second press
5.2.3 Trigger-Off
Timeout
When this timeout is selected, the reader turns OFF automatically after the desired
period of time.