Scanning Features
Product Reference Guide
287
Stand Mode Off Time
This feature specifies the amount of time reader illumination stays off after
pulling the trigger when in Stand Mode. The configurable range is 01 to 32
by 01 in increments of 500ms (500ms to 16 seconds).
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield two digits. For example: 2 =
02, 5 = 05, 20 = 20, etc.
3. Go to
and scan the ENTER/EXIT PROGRAMMING MODE bar
code to enter Programming Mode.
4. Scan the bar code: Set Stand Mode Illuminator Off Time.
5. Scan the appropriate two digits from the keypad in
, that represent the setting which was determined in the steps
above. You will hear a two-beep indication after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
ming Mode.
This completes the procedure. See
for some examples of how to
set this feature.
Table 14. Stand Mode Off Time
STEP
ACTION
EXAMPLES
1
Desired Setting
500 ms
1 Second
5.5 Seconds
16 Seconds
2
Pad leading zero
01
02
11
32
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT STAND MODE OFF TIME
5
Scan Two Characters From
‘0’ and ‘1’
‘0’ and ‘2’
‘1’ and ‘1’
‘3’ and ‘2’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for GBT4400BK
Page 42: ...Setup 32 Gryphon I GD44XX GBT4400 GM440X ...
Page 46: ...Enter Exit Programming Mode 36 Gryphon I GD44XX GBT4400 GM440X NOTES ...
Page 60: ...Enter Exit Programming Mode 50 Gryphon I GD44XX GBT4400 GM440X NOTES ...
Page 102: ...Enter Exit Programming Mode 92 Gryphon I GD44XX GBT4400 GM440X NOTES ...
Page 248: ...238 Gryphon I GD44XX GBT4400 GM440X NOTES ...
Page 308: ...References 298 Gryphon I GD44XX GBT4400 GM440X NOTES ...
Page 338: ...Keypad 328 Gryphon I GD44XX GBT4400 GM440X A B C D E F ...
Page 348: ...Scancode Tables 338 Gryphon I GD44XX GBT4400 GM440X NOTES ...