PEN READER CONFIGURATION
Read the restore default code, and then read the PEN interface
selection code.
RESTORE DEFAULT
Ì$+$*oÎ
PEN
Ì$+CP6$-BÎ
DEFAULT VALUES
USB DEFAULT SETTINGS
DATA FORMAT
: code identifier disabled, no field adjustment,
code length not transmitted, character replacement disabled.
USB KEYBOARD
: USA keyboard, FIFO enabled, inter-
character and inter-code delays disabled, control character
emulation = ctrl+shift+key.
USB COM
: no handshaking, delay disabled, rx timeout 5 sec.,
ack/nack disabled, FIFO enabled, serial trigger lock disabled.
Default Headers and Terminators for each USB mode:
-
USB-KBD: no header, terminator = ENTER
-
USB-KBD-ALT-MODE: no header, terminator = CR
-
USB-COM: no header, terminator = CR-LF
-
USB-IBM-TABLE TOP: not applicable
-
USB-IBM-HAND HELD: not applicable
RS232 Standard DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking,
delay disabled, rx timeout 5 sec., ack/nack disabled, FIFO
enabled, serial trigger lock disabled.
DATA FORMAT
: code identifier disabled, no field adjustment,
code length not transmitted,
no header
,
terminator = CR-LF
,
character replacement disabled.
RS232 Nixdorf DEFAULT SETTINGS
9600 baud, parity odd, 8 data bits, 1 stop bit, handshaking
hardware (RTS/CTS), delay disabled, rx timeout 9.9 sec.,
ack/nack disabled, FIFO disabled, serial trigger lock disabled.
DATA FORMAT
: code identifier enabled, no field adjustment,
code length not transmitted,
no header
,
terminator = CR
,
character replacement disabled.