MX-E Series Hardware Guide
Basler Line Scan Camera Connection
61
Datalogic S.r.l.
NOTE 1
: To help prevent ground loops and possible false triggering, you must connect I/O Ground to Camera Power
Ground.
Input 3 +
Phase B Line Trigger
(Quadrature Encoder)
As sinking input
Off 0 to +0.8 VDC
On: +2.0 to +5 VDC
As sourcing input (see Input 3 Pullup)
Off: +2.0 to +5 VDC
On 0 to +0.8 VDC
Maximum: +5 VDC
Output 1 -
Not Currently Supported
DO NOT USE
Output 1 +
Not Currently Supported
DO NOT USE
Output 2 -
Not Currently Supported
DO NOT USE
Output 2 +
Not Currently Supported
DO NOT USE
Input 1 5VDC
Frame Start Trigger Pullup -
use if Input 1 needs sourcing
input
Maximum: +5 VDC
Input 2 5VDC
Line Trigger Pullup - use if
Input 2 needs sourcing input
Maximum: +5 VDC
Input 3 5VDC
Line Trigger Pullup - use if
Input 3 needs sourcing input
Maximum: +5 VDC
Terminal
Signal Name
Notes
Summary of Contents for E1 Series
Page 1: ...MX E Series Hardware Guide for Processor and Cameras Revision Date July 19 2018 ...
Page 4: ......
Page 18: ...Before You Call MX E Series Hardware Guide Datalogic S r l 12 ...
Page 28: ...Battery MX E Series Hardware Guide Datalogic S r l 22 ...
Page 56: ...JAI Cameras MX E Series Hardware Guide Datalogic S r l 50 661 0402TerminalBlockDimensions ...
Page 58: ...JAI Cameras MX E Series Hardware Guide Datalogic S r l 52 JAITerminalConnections sinking ...
Page 64: ...Basler Cameras MX E Series Hardware Guide Datalogic S r l 58 TerminalConnections ...
Page 116: ...M1xx and E1xx MX E Series Hardware Guide Datalogic S r l 110 ...
Page 120: ...Index MX E Series Hardware Guide Datalogic S r l iv ...