background image

 

 

DX8200A-3002 QUICK GUIDE

 

 

 

Mechanical Installation: 

 
DX8200A-3002 can be installed to operate in any position. There are 4 slots (dia. 8.5 mm) on the sides of the 
scanner for mounting. The diagram below can be used for installation; refer to the Reading Diagrams for correct 
positioning of the scanner with respect to the reading zone and scanner orientation. 
 
 
 
 

 
 

470

 [18.50]

30

0

 [11

.8

1]

=

=

180

 [7

.0

9]

22

 [0.87]

406

 [15.98]

22

 [0.87]

8.

5

 [0

.33]

14

1

 [

5.5

5]

147

 [5

.7

9]

10

 [0

.39]

370

 [14.57]

=

=

370

 [14.57]

=

=

=

=

60.

5

 [

2.3

8]

70.

5

 [2.

78]

 4

 

DX8200A-3002 Overall Dimensions 

 
 
 

Scanner Direction 

 
The different scanner orientations are illustrated in the following figures: 
 

 

 

DX8200A-3002 Scanner Direction 0° (Forward) 

DX8200A-3002 Scanner Direction 180° (Reverse) 

PackTrack™ Coordinate Reference Point
where x, y, z = 0 

Top View

Conveyor Direction 

Top View

Conveyor Direction

Summary of Contents for DX8200A-3002

Page 1: ...eypad 1 Phase On LED Yellow 3 Power On LED Green 2 TX Data LED Green 5 Network LED Red 6 Encoder LED Yellow 4 LCD Display 7 Figure C Lonworks 17 pin Male Connector 1 Lonworks 17 pin Female Connector 2 NOTE For further details on product installation see the complete Reference Manual available on the configuration CD ROM included with this product 1 2 7 3 4 5 6 1 2 2 1 2 3 4 ...

Page 2: ... case of motor slow down READING FEATURES Scan rate 1000 scans s 500 per leg Maximum resolution Max reading distance Max reading width Max depth of field see reading diagrams on page 9 USER INTERFACE LCD Display 2 lines by 20 characters LCD Keypad 3 keys LED indicators Power On green Phase On yellow Encoder yellow TX Data green Network red SOFTWARE FEATURES Readable Codes Interleaved 2 5 Code 39 S...

Page 3: ...System 480W 93ACC1767 FS 1 Frame Shaper 8 pcs 93ACC1750 S30 Photocell Kit 93ACC1782 MEP 542 Photocell Kit PNP 93ACC1727 MEP 543 Photocell Kit NPN 93ACC1728 OEK 2 Optical Encoder Kit 10 m cable Spring 93ACC1770 OEK 1 Optical Encoder Kit 10 m cable 93ACC1600 BTK 8100 Bus Terminator Kit 5 pcs 93ACC1090 BTK 8500 IP65 Terminator Kit 2 pcs 93A051286 PLL 8000 Optocoupled PLL device 93ACC1280 CAB 8100 10 ...

Page 4: ...onnected Cable shield B internally connected by 3 CHASSIS capacitor to chassis 4 TXAUX Transmit data of auxiliary RS232 referred to SGND 5 SGND Signal ground connected to GND 6 RXAUX Receive data of auxiliary RS232 referred to SGND 7 VS_I O Supply voltage of I O circuit 8 Lon A Lonworks a line positive pin 9 Lon A Lonworks a line negative pin 10 Lon B Lonworks b line positive pin 11 Lon B Lonworks...

Page 5: ...B SC6003 Power Net VAC INPUT CAB SC6103 Cable PWO LONWORKS ENCODER PS PS Aux CAB 850x CAB 850x CAB 850x CAB 850x up to 3 scanners per branch BTK8500 Bus Return DX8200A 3002 DS8100A 3002 CAB 850x up to 4 scanners per branch BTK8500 Bus Return DX8200A 3002 DX8200A 3002 DS8100A 3002 DS8100A 3002 DS8100A 3002 CAB 850x CAB 850x ...

Page 6: ...WORKS ENCODER PS PS Aux CAB 850x CAB 850x BTK8500 CAB 850X CAB 850x CAB 850x Extended I O ETHERNET SC6000 CAB SC6003 CAB SC6003 Power Net VAC INPUT PWO CAB PWO 03 Redundancy CAB 850X CAB 850x CAB 850x BTK8500 DX8200A DX8200A DS8100A DS8100A ENCODER PS PS Aux LONWORKS Working Controller Protecting Controller to Host to Host DX8200A DX8200A DS8100A DS8100A ...

Page 7: ...DX8200A 3002 QUICK GUIDE 7 Example of Redundant System ...

Page 8: ...espect to the reading zone and scanner orientation 470 18 50 300 11 81 180 7 09 22 0 87 406 15 98 22 0 87 8 5 0 33 141 5 55 147 5 79 10 0 39 370 14 57 370 14 57 60 5 2 38 70 5 2 78 N 4 DX8200A 3002 Overall Dimensions Scanner Direction The different scanner orientations are illustrated in the following figures DX8200A 3002 Scanner Direction 0 Forward DX8200A 3002 Scanner Direction 180 Reverse PackT...

Page 9: ...24 28 16 40 15 Compliance Laser Safety Figure A Warning and Device Class Label 1 Figure B Device Identification Label 1 The scanner is classified as a Class 2 laser product according to EN60825 1 regulations and as a Class II laser product according to CDRH regulations Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to hazardous laser light ...

Page 10: ...ording to EN 60825 1 regulations and as Class IIIb laser products according to CDRH regulations As it is not possible to apply a classification label on the laser diodes used in this device the following label is reproduced here LASER LIGHT AVOID EXPOSURE TO BEAM CLASS 3B LASER PRODUCT MAXIMUM OUTPUT RADIATION 30 mW EMITTED WAVELENGTH 630 680 nm TO EN 60825 1 2001 Laser Diode Class Label Any viola...

Page 11: ...de las leyes de los Países Miembros respecto a la compatibilidad electromagnética y las Medidas de seguridad relativas al producto Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti This declaration is based upon compliance of the products to the following standards Cette déclaration repose sur la conformité des produits aux normes suivantes Diese Erklärung basiert dar...

Reviews: