SPECIFICATIONS

STEP1 - CHECK HARDWARE

STEP2 - CONNECT TO HOST

STEP3 - POSITION SCANNER

STEP4 - INSTALL SOFTWARE UTILITY

DIMENSION

SCANNING RANGE

Light source 

625nm visible red LED

Scan rate 

200 scans/sec

Sensor 

752×480 CMOS sensor

Resolution 5mil/ 

0.127mm

PCS 30%
Width of Field  100mm (13Mil Code39)
Depth of Field   5 Mil Code39: Readable
 

 10 Mil Code39: 50 - 150mm

 

 15 Mil Code39: 50 - 200mm

 

 13 Mil UPC/EAN: 55 - 180mm

 

 20 Mil QR Code: 50 - 200mm

Dimension 

W56 x L41 x H20 mm

Housing 

ABS (Housing), PC (Back Cover)

Weight 

120g ± 10g

Cable Length  90cm/35.4in (Fixed Cable)
Interface 

RS232, USB HID

Voltage 5VDC±5%

Working Current

 < 350mA

Standby Current

 < 50mA

Operating Temp. 

 

-10 to 55

˚

C (14

˚

F to 131

˚

F)

Storage Temp.   -20 to 65

˚

C (-4

˚

F to 149

˚

F)

Ambient Light  100,000 lux

Drop Durability

 1.5M

Sealing IP55
Symbologies  QR Code, DataMatrix, PDF417 and all
 

major 1D barcodes

Top View

Front View

Pin

Signal

1
2
3

+5VCC

Data -
Data +

4

GND

RS232 (D-Sub 9 Female):

USB (Type A Male):

Pin

Signal

2
3
5
7
8

TXD(Out)

RXD(In)

GND

CTS(In)

RTS(Out)

USB Hardware

USB Connection

RS232 Hardware

RS232 Connection

1. Connect the scanner to the host.
2. The scanner is powered by the USB connection.
3. Data will be sent as HID keyboard input.

2. Pitch the scanner at a minimum of ±5

˚

 to avoid specular

    reflection.

1. Maximum Scan Angle: Skew ±55

˚

, Pitch ±55

˚

, Tilt ±360

˚

Skew ±55

˚

 

Pitch ±50

˚

 

Tilt ±360

˚

 

Based on different hardware & configuration method, 
there are 2 types of software utility:

1. 

EZU

 Software - works with USB interface scanner

                            and supports configuration barcodes

2. 

BEO

 Software - works with RS232 interface scanner

 

           and supports command operation

Both are available for download from below link:

1. Connect the scanner to the host.
2. Connect a power adapter(sold separately) to the
    RS232 connector’s DC Jack as external power supply.
3. Data will be sent serially over RS232, with
    communication settings of 9600-8-N-1

10

 Mil Code39: 50 - 1

50mm

13

 Mil EAN/UPC: 55 - 1

80mm

15

 Mil Code39: 50 - 200mm

20 Mil QR Code: 50 - 200mm

36

˚

Unit: MM