INSTALLATION – DX8200 SERIAL INTERFACE
25
2
2.5 TYPICAL
LAYOUTS
2.5.1 Standard
(Point-to-Point)
In this layout, data is transmitted to the Host on the main serial interface. The selectable
interface types are RS232, RS485 full-duplex or 20 mA C.L. communications.
2
Terminal
1
Host
3
Main serial interface
Auxiliary serial interface
Presence sensor (for On-Line mode)
2
3
1
DX8200
OR
9-pin main connector
17-pin Aux/Input connector B
(for presence sensor and auxiliary interface)
25-pin main connector with I/O
Figure 29 - Standard (point-to-point) layout
When On-Line Operating mode is used, the scanner is activated by a presence sensor when
the object enters its reading zone.
The data is also transmitted on the Auxiliary interface (if configured for Standard
communication mode), as well as on the Main interface. The auxiliary interface uses RS232
for this layout.
Host Mode programming can be accomplished either through the Main or the Auxiliary
interface.