Datalogic DX6400 Quick Reference Manual Download Page 9

DX6400 QUICK GUIDE 

9

 

 

READING FEATURES 

Scan rate 

up to 1500 scans/s (750 per leg) 

Maximum Resolution 
Max. Reading Distance 
Max. Reading Width 
Max. Depth of Field 

(see reading diagrams) 

USER INTERFACE 

LCD Display 

2 lines by 16 characters LCD 

Keypad 3 

keys 

LED Indicators 

Power On (red) 

Phase On (yellow) 

TX Data (green) 

SOFTWARE FEATURES 

Readable Codes 

Interleaved 2/5 
Code 39 Standard 
Codabar 
Code 128 
GS1-128 (ex EAN 128) 
Code 93 (standard and full ASCII) 
EAN/UPC (including Add-on 2 and Add-on 5) 
GS1 DataBar (including Limited and Expanded) 

Code Selection 

Up to 10 codes during one reading phase 

Headers and Terminators 

Up to 128-bytes headers and 128-bytes terminators 

Operating Modes 

On Line, Serial On Line, Automatic, Test, PackTrack™, Continuous

Configuration Modes 

Genius™ utility program 

Parameter Storage 

Non-volatile internal FLASH 

ENVIRONMENTAL FEATURES 

Operating Temperature 

0° to +40 °C (+32° to +104 °F) 

Storage Temperature 

-20° to +70 °C (-4° to +158 °F) 

Humidity 

90% non condensing 

Ambient Light Immunity 

10000 lux 

Vibration Resistance 

 

EN 60068-2-6 
2 hours on each axis 

14 mm @ 2 to 10 Hz; 

1.5 mm @ 13 to 55 Hz; 

2 g @ 70 to 200 Hz 

Shock Resistance 

 

EN 60068-2-27 
3 shocks on each axis 

30 g; 11 ms 

Protection Class – EN 60529 

IP64 

PHYSICAL FEATURES

 

Mechanical Dimensions 

225.9 x 149.8 x 116.8 mm (8.89 x 5.90 x 4.60 in) 

Weight 

2.1 kg. (4.62 lbs) 

 
 
 
 

MODEL DESCRIPTION 

 

 

Decoder Model

10 = Master/Slave 
12 = Ethernet

DX6400 - 100 - 0XX

 

 

Summary of Contents for DX6400

Page 1: ...twork applications For other types of installations such as ID NET Pass Through Multiplexer Layout etc refer to the DX6400 Reference Manual available on the CD For complete scanner configuration using...

Page 2: ...t page which describes specific Info Features Applications Models Accessories and Downloads including the Genius utility program which allows device configuration using a PC It provides RS232 and Ethe...

Page 3: ...2 4 3 Laser Beam Output Window 1 Laser Safety Label 2 Programming Keypad 1 Phase On LED Yellow 3 TX Data LED Green 2 Power On LED Red 4 LCD Display 5 Lonworks 9 pin Male Connector 1 Lonworks 9 pin Fem...

Page 4: ...External Trigger PS input CBX100 jumper set to accept scanner power Encoder connected to Input 2 Encoder input Synchronized Network with DS8100A Master and 6K Family Slaves Serial Host CAB 610x CBX100...

Page 5: ...ted by positioning a BT 6000 terminator on the DX6400 Standard master reader BT 6000 female side and on the last slave reader BT 6000 male side For Fieldbus models Lonworks master only the bus is inte...

Page 6: ...rity insensitive only with CBX500 I4A IN 4A polarity insensitive only with CBX500 I34B IN 3B IN 4B Reference polarity insensitive only with CBX500 Outputs V Power Source Outputs V Power Reference Outp...

Page 7: ...reference of IN3 and IN4 polarity insensitive 9 13 VS Supply voltage positive pin 23 25 26 GND Supply voltage negative pin 14 1 25 13 25 pin male D sub Connector 10 19 1 18 9 26 26 pin male D sub Con...

Page 8: ...85 half duplex 1200 to 115200 Auxiliary RS232 1200 to 115200 Other Common Communication Interfaces Lonworks 1 25 Mb s Model Dependent Communication Interfaces Ethernet 100 Mb s Inputs Ext Trigger 1 En...

Page 9: ...nd Terminators Up to 128 bytes headers and 128 bytes terminators Operating Modes On Line Serial On Line Automatic Test PackTrack Continuous Configuration Modes Genius utility program Parameter Storage...

Page 10: ...pin to 17 pin 93A051288 CAB 6505 Fam 6K 8K cross cable 5 m 9 pin to 17 pin 93A051289 CAB ETH M01 M12 IP67 Ethernet Cable 1 m 93A051346 CAB ETH M03 M12 IP67 Ethernet Cable 3 m 93A051347 CAB ETH M05 M1...

Page 11: ...ut don t remove the two screws on top of the head 4 affix the head onto the base carefully aligning the four fixing screws and progressively tightening them about half way 5 completely tighten the two...

Page 12: ...NAMIC FOCUS The DX6400 has an innovative linear motor designed to control the focus position of the scanner via software This dynamic system called FLASH is able to move the focus position rail to rai...

Page 13: ...21 23 26 Code 39 Code Resolution mm 1 00 28 29 30 31 32 34 Table 2 Minimum Code Height for Omnidirectional Reading mm Conveyor Speed m s 0 5 1 1 5 2 2 5 3 0 38 10 12 14 16 18 20 0 50 12 13 16 18 20 22...

Page 14: ...o the edge of the DX6400 scanner as shown in the figure above CONDITIONS Code Interleaved 2 5 or Code 39 PCS 0 90 DX6400 100 0XX Resolution 0 50 mm 20 mils in in cm cm 20 40 10 30 10 0 10 20 30 10 0 4...

Page 15: ...IS APERTURE AVOID EXPOSURE TO BEAM CAUTION LASER LIGHT WHEN OPEN AVOID EXPOSURE LASER LIGHT IS EMITTED FROM THIS APERTURE Laser Safety Labels DX6400 CAUTION CLASS 3B LASER LIGHT WHEN OPEN AVOID EXPOSU...

Page 16: ...ed operation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protec...

Reviews: