Datalogic DX6400 Quick Reference Manual Download Page 16

DX6400 QUICK GUIDE 

16 

 

 

POWER SUPPLY 

 

This product is intended to be installed by Qualified Personnel only.

 

 

All DX6400 Models:

 

This device is intended to be supplied by a UL Listed Power Unit marked “Class 2” or LPS power source 
which supplies power directly to the scanner via the 25/26-pin connector. 

 
 
 

CE COMPLIANCE 

 

Warning: 

This is a Class A product. In a domestic environment this product may cause radio interference in which case the 
user may be required to take adequate measures. 
 
 
 

FCC COMPLIANCE 

 
Modifications or changes to this equipment without the expressed written approval of Datalogic could void the 
authority to use the equipment. 
 
This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) 
This device may not cause harmful interference, and (2) this device must accept any interference received, 
including interference which may cause undesired operation. 
 
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference 
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate 
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause 
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause 
harmful interference in which case the user will be required to correct the interference at his own expense. 
 
 
 
 
 

PATENTS 

 
 
This product is covered by one or more of the following patents. 
 
U.S. patents: Re. 36,251; 5,992,740; 6,049,406;  6,347,740 B1;  6,394,352 B1;  6,443,360 B1;  6,629,639 B2; 
6,742,710 B2; 7,161,685 B1; 7,195,162 B2. 

European patents: 652,530 B1; 643,362 B2; 786,734 B1;  789,315 B1;  851,376 B1;  959,426 B9;  1,300,798 B1; 
1,217,571 B1; 1,363,228 B1; 1.607,901 B1. 

Japanese patents: 3,793,585 B2; 4,033,958 B2; 4,129,302 B2; 4,376,353 B2; 4,451,592 B2. 
 
 
 
 

Summary of Contents for DX6400

Page 1: ...twork applications For other types of installations such as ID NET Pass Through Multiplexer Layout etc refer to the DX6400 Reference Manual available on the CD For complete scanner configuration using...

Page 2: ...t page which describes specific Info Features Applications Models Accessories and Downloads including the Genius utility program which allows device configuration using a PC It provides RS232 and Ethe...

Page 3: ...2 4 3 Laser Beam Output Window 1 Laser Safety Label 2 Programming Keypad 1 Phase On LED Yellow 3 TX Data LED Green 2 Power On LED Red 4 LCD Display 5 Lonworks 9 pin Male Connector 1 Lonworks 9 pin Fem...

Page 4: ...External Trigger PS input CBX100 jumper set to accept scanner power Encoder connected to Input 2 Encoder input Synchronized Network with DS8100A Master and 6K Family Slaves Serial Host CAB 610x CBX100...

Page 5: ...ted by positioning a BT 6000 terminator on the DX6400 Standard master reader BT 6000 female side and on the last slave reader BT 6000 male side For Fieldbus models Lonworks master only the bus is inte...

Page 6: ...rity insensitive only with CBX500 I4A IN 4A polarity insensitive only with CBX500 I34B IN 3B IN 4B Reference polarity insensitive only with CBX500 Outputs V Power Source Outputs V Power Reference Outp...

Page 7: ...reference of IN3 and IN4 polarity insensitive 9 13 VS Supply voltage positive pin 23 25 26 GND Supply voltage negative pin 14 1 25 13 25 pin male D sub Connector 10 19 1 18 9 26 26 pin male D sub Con...

Page 8: ...85 half duplex 1200 to 115200 Auxiliary RS232 1200 to 115200 Other Common Communication Interfaces Lonworks 1 25 Mb s Model Dependent Communication Interfaces Ethernet 100 Mb s Inputs Ext Trigger 1 En...

Page 9: ...nd Terminators Up to 128 bytes headers and 128 bytes terminators Operating Modes On Line Serial On Line Automatic Test PackTrack Continuous Configuration Modes Genius utility program Parameter Storage...

Page 10: ...pin to 17 pin 93A051288 CAB 6505 Fam 6K 8K cross cable 5 m 9 pin to 17 pin 93A051289 CAB ETH M01 M12 IP67 Ethernet Cable 1 m 93A051346 CAB ETH M03 M12 IP67 Ethernet Cable 3 m 93A051347 CAB ETH M05 M1...

Page 11: ...ut don t remove the two screws on top of the head 4 affix the head onto the base carefully aligning the four fixing screws and progressively tightening them about half way 5 completely tighten the two...

Page 12: ...NAMIC FOCUS The DX6400 has an innovative linear motor designed to control the focus position of the scanner via software This dynamic system called FLASH is able to move the focus position rail to rai...

Page 13: ...21 23 26 Code 39 Code Resolution mm 1 00 28 29 30 31 32 34 Table 2 Minimum Code Height for Omnidirectional Reading mm Conveyor Speed m s 0 5 1 1 5 2 2 5 3 0 38 10 12 14 16 18 20 0 50 12 13 16 18 20 22...

Page 14: ...o the edge of the DX6400 scanner as shown in the figure above CONDITIONS Code Interleaved 2 5 or Code 39 PCS 0 90 DX6400 100 0XX Resolution 0 50 mm 20 mils in in cm cm 20 40 10 30 10 0 10 20 30 10 0 4...

Page 15: ...IS APERTURE AVOID EXPOSURE TO BEAM CAUTION LASER LIGHT WHEN OPEN AVOID EXPOSURE LASER LIGHT IS EMITTED FROM THIS APERTURE Laser Safety Labels DX6400 CAUTION CLASS 3B LASER LIGHT WHEN OPEN AVOID EXPOSU...

Page 16: ...ed operation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protec...

Reviews: